Home Companies CITEST DIAGNOSTICS INC.

4.5-25.6g/dL Hemoglobin Hb Test Meter Quantitative Detection 1000 Records

CITEST DIAGNOSTICS INC.

Contact Us

Trade Verify

Address: 170-422, Richards Street, Vancouver BC V6B 2Z4, CANADA

Contact name:Rosy

Inquir Now

CITEST DIAGNOSTICS INC.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

4.5-25.6g/dL Hemoglobin Hb Test Meter Quantitative Detection 1000 Records

City & Province hangzhou zhejiang
Categories Camera Chargers
InquireNow

Product Details

Hemoglobin (Hb) Test Meter With Accurate Results, Professional Use Only

 

Name:Hemoglobin (Hb) Test Meter With Accurate Results, Professional Use Only
Specimen:Wole Blood
Reading Time:<15 Seconds
Storage Temperature:-10 - 50℃
Methodology::Reflectance Photometer
Specimen Volume:10 PL
Battery Life:360 Hours Or 2700 Tests
Memory:1000 Records
Meter Dimension:120mm*71mm*26mm
Format:Meter
Certificate:CE/CE0123/CE0197
Pack:2T/50T/1Set/100pcs/box
Shelf Life:5 Years
Measurement Range::4.5~25.6g/dL,45~256 G/L, 0.03-0.16 Mmol/L
Power Source:3 AAA Batteries
Units Of Measure:G/dU G/L, Mmol/L
Automatic Shut Off:6 Minutes After Last Action
Display Size:47*41mm

 

Hemoglobin (Hb) Test Meter with Accurate results, professional use only

 

1 Intended Use

The Hemoglobin (Hb) Test Meter is intended for the quantitative determination of hemoglobin and calculated hematocrit (HCT) in non-anticoagulated capillary whole blood or anticoagulated venous whole blood. The Hemoglobin Test Strip includes a mesh covered sample reaction zone. Specimen is applied to the center of the sample reaction zone. The hemoglobin is converted to methemoglobin to cause a color change on the strip. The meter reads the reflection of the strip every second until the end point of the reaction is detected. The reflection at the end point is directly proportional to the hemoglobin concentration.

 

2 Scope of Application

The Hemoglobin (Hb) Test Meter works with certain reagents strips manufactured by Citest. for the quantitative detection. It’s for in vitro diagnostic professional use only. It may be used in emergency departments, clinical departments or medical services (such as community health centers), etc.

 

3 Product Name and Model Type

Product Name:Hemoglobin (Hb) Test Meter

Model Type:AHR-100

 

4 Technical Specification

 

SpecificationTechnical Parameters
MethodologyReflectance Photometer
Test Time<15 seconds
Measurement Range4.5~25.6g/dL
SpecimenWhole Blood
Specimen Volume10 μL
Power Source3 AAA batteries
Battery Life360 hours or 2700 tests
Units of Measureg/dL, g/L, mmol/L
Memory1000 records
Automatic Shut Off6 minutes after last action
Meter Dimension120mm*71mm*26mm
Display Size47*41mm
Weight (without Batteries)83g
Meter ConnectorsUSB cable for Data Transfer or Power (optional)

 

 

5 Working and Storage Condition

 

ParametersWorking ConditionStorage and Transport Condition
Temperature15-30℃-10-40℃
Relative Humidity≤80%≤90%
Atmospheric Pressure86-106kPa86-106kPa
AltitudeUp to 2000mUp to 2000m
PlaceIndoor use, stable table, avoid of direct strong light and strong electromagnetic interference sourceClean, Ventilative, Stable
 
How to use?
 

Step 1: Unscrew the lancing device cover from the body of the lancing device.

Step 2: Insert a sterile lancet into the lancet holder and push it until stop in the lancet holder.

 

 

Step 3: Hold the lancet firmly in the lancet holder and twist the safety tab of the lancet, then pull the safety tab off. Save the safety tab for lancet disposal.

 

 

Step 4: Carefully screw the cover back to the lancing device. Avoid contact with the exposed needle. Make sure the cover is fully seated on the lancing device

 

 

Step 5: Adjust the puncture depth by rotating the lancing device cover. There are a total of 6 puncture depth settings. To reduce discomfort, use the lowest setting that still produces an adequate drop of blood.

 

 

Step 6: Pull the cocking barrel back to set the lancing device. A click may be heard. The device is now loaded and ready for obtaining a drop of fingertip blood.

Step 7: Prior to collecting the capillary blood specimen, make sure the patient’s hand is warm and relaxed. Massage the hand from the wrist up to the fingertip a few times to encourage blood flow. Clean the testing site with an alcohol swab and then dry the testing site thoroughly.

 

Step 8: Hold the lancing device against the side of the finger to be lanced with the cover resting on the finger. Push the release button to prick the fingertip. A click should be heard as the lancing device activates. Gently massage from the base of the finger to the tip of the finger to obtain the required blood volume

 

Step 9: Wipe away the first drop of blood. Apply light pressure to obtain a second drop of blood. Hold the tube slightly downward and touch the tip of the capillary transfer tube to the blood drop. Capillary action will automatically draw the sample to the fill line and stop.

 

Note: Make sure the blood covers the air vent of the tube or it will be hard to squeeze blood out. Never squeeze the capillary transfer tube while sampling.

 

Step 10: Unscrew the lancing device cover. Place the safety tab of the lancet on a hard surface and carefully insert the lancet needle into the safety tab. Press the release button to make sure that the lancet is in the extended position. Slide the ejection button forward to eject the used lancet. Place the lancing device cover back on the lancing device.

Note: Dispose of the used lancet according to local regulations.

 

 

Hot Products

Adulteration Dipstick, Biochemistry Reagents , Convenient Urine Test Dipstick The Urine Adulteration ...
Vaginal pH Rapid Test, High Sensitivity PH Rapid Test Biochemistry Reagents result in 5 minutes ...
Viral Transport Medium (Non-inactivated Type), Biochemistry Test Kit, testing laboratory Inactivated ...
Product features Parameters Format Tube withTransparent Reagent Certificate CE Pack 1mL/T, 2mL/T, ...
Hemoglobin (Hb) Test Meter With Accurate Results, Professional Use Only Name: Hemoglobin (Hb) Test ...
Product Description: CPV + CCV + Giardia Lamblia Antigen Combo Rapid Test Cassette is a combined ...