Home Companies ZHEJIANG XINCHOR TECHNOLOGY CO., LTD.

C30 Concrete Adhesive Anchoring System 420ml 2:1 For Thread Rod

ZHEJIANG XINCHOR TECHNOLOGY CO., LTD.
Active Member

Contact Us

[China] country

Address: 1ST FLOOR, UNIT 1, NO.9 GUANSHAN ROAD, FENGDU INDUSTRIAL PARK, PINGYAO, YUHANG, HANGZHOU, ZHEJIANG

Contact name:Colin Mao

Inquir Now

ZHEJIANG XINCHOR TECHNOLOGY CO., LTD.

C30 Concrete Adhesive Anchoring System 420ml 2:1 For Thread Rod

Country/Region china
City & Province hangzhou zhejiang
Categories Adhesives & Sealants
InquireNow

Product Details

Long Term Load Stability Adhesive Anchoring System 420ml 2:1 For Thread Rod

Chemical anchor adhesive, epoxy injection mortar, Chemical fixing glue,

Chemical anchoring system used for anchoring and rebar connections in concrete.

 

Item #: FixingChor142

Capacity: 420ml

Materials: Epoxy

Mixing Ratio: 2:1

 

 

Product Description:

 

Adopted with modified epoxy resin and composite materials, XQ-IME Injection Anchoring Adhesive is a two-component, Styrene Free system for use as a high strength, non-shrink anchor grouting material. Its advantage on steel bar planting has been proved by many testimonies. Compares with other adhesive, it is a new high performance, Eco-friendly anchoring adhesive which has strong bonding strength and high efficiency as well as irritation free and low odor.

 

Key Features

Design flexibility permitted for sustained load performance at elevated temperature Job site versatility can be specified for dry and damp conditions when in-service temperatures range from -40°F (-40°C) to 150°F (65°C)

Recognized per AC308 to be used for rebar development and splice length design provisions of ACI 318

 

Easy hole-cleaning, no power-brushing required

 

1:1 two-component, high-solids, epoxy-based anchoring adhesive formula

When properly mixed, will be a uniform teal color

Suitable for use under static and seismic loading conditions in cracked and uncracked concrete and masonry

 

Suitable for use in dry or water-saturated concrete

 

Use with threaded rod or rebar

Substrate installation temperature from 50°F (4°C) to 110°F (38°C)

In-service temperature range of –40°F (–40°C) to 150°F (65°C)

For best results, store between 45°F (7°C) and 90°F (32°C)

Shelf life of 24 months

Volatile Organic Compound (VOC) –3 g/L

 

 

 

Technical Parameter:

 

1. Basic parameters

1) Appearence

Part A (main): white cream

Part B (hardener): red cream / grey cream

2) Mixed Viscosity: 18-22Pa.s

3) Hardened density: 1.50±0.10g/cm3

4) Mixing ratio (Volume ratio):  650ml(1:1) 

5) Shelf time: 24 months

 

2 Main Performance

Testing projectConditionIndex
Gel Performance  (According to China National Standard GB50728-2011)
Splitting Tensile Strength (MPa)Under (23±2)℃, (50±5)%RH, tested by loading speed of 2mm/min≥8.5
Flexural Strength (MPa)

≥50

(no fragment damage)

Compressive Strength (MPa)≥60
Bonding Capacity (According to China National Standard GB50728-2011)
Steel-Steel Tensile Shear Strength (MPa)(23±2)℃  (50±5)%RH≥10
Bonding strength of Ribbed steel bar (or screw) with concrete under constrain drawing condition(23±2)℃ (50±5)%RHC30,Ф25,L=150mm≥11
C60,Ф25,L=150mm≥17
Steel-Steel T-peeling strength (mm)(23±2)℃,(50±5)%RH≤25
Non-volatile content(105±2)℃,(180±5)min≥99%
Ageing resistance to heat and humidity 90d
Reduction rate of tensile strengthUnder normal room temperature≤12%
 (According to China National Standard JGJ145-2013)
Tensile Strength (after high temperature welding)

Dia12 Grade II steel, C30 concrete

Hole dia.16mm, Depth: 150mm

55.1N, 57.0N, 54.8N
 

3 Technical Data

Anchoring Adhesive used with thread rod

Thread Rod Dia

 

C30 Concrete

M10M12M16M20M24
Drilling Dia.(mm) 1214182428
Depth (mm) 90110145180220
Damage Pulling force KNGrade 5.8 Steel2942.278.5122.5254.5
Grade 8.8 Steel / A4 SS36.852.994.1147.0211.7
Damage Cutting force KNGrade 5.8 Steel17.425.347.173.5105.9
Grade 8.8 Steel`27.840.575.3117.6169.4
A4 SS24.435.465.9102.9105.9
Designed Pulling force KN 12.017.0230.652.475.2
Designed Cutting Force KNGrade 5.8 Steel12.217.632.951.574.1
Grade 8.8 Steel18.627.050.278.4113.0
A4 SS13.019.035.355.256.9
Holes for each 5425853
 

 

Anchoring Loading Capacity of rebar to C30 concrete (designed value KN)

 

Rebar d(mm)1012141618202225283032
Hole D(mm)1416182225283032363840
Bar planting depth (mm)10019.8          
12023.827.6         
14027.732.236.3        
16031.736.841.545.8       
180 41.446.651.655      
200 46.051.857.361.162.8     
220  57.063.167.269.171.5    
240  62.268.973.375.47879.2   
260   74.679.381.784.585.896.1  
280   80.485.488.091.092.4102.9107.4 
300    91.594.297.599109.8114.6115.8
320    97.6100.5103.9105.6116.6121.8123
340    103.7106.8110.4112.2123.5128.9130
360     113.0117.0118.8130.4136.1137.5
380     119.3123.5125.3137.2143.3144.8
400     125.6130131.9144.1150.4152
420      136.5138.5150.9157.6159.2
440      143145.1157.8164.7166.5
480      149.5151.7164.7171.9173.7
500      1561583171.5179.1181
550       164.9188.7197199.1
600       181.4205.8214.8217.1
650       197.9223232.7235.2
700        240.1250.6253.2
750        257.3268.5271.5
800         286.4289.6
850          307.7
anchoring length (mm)147149178210250300351446538592666
steel yield (mm)23.633.946.260.376.394.2114147.2184.6212.1241.2
 

 

 

Actual Tensile Strength (KN)

Grade II rebar fy=310 N/mm (designed), fy=310 N/mm (standard)

Concrete: C30

 

Rebar d(mm)10121416182022252832
Hole D(mm)14161822252830323640
Bar planting depth (mm)10030.3         
12036.738.5        
14042.247.553.1       
160 58.862.768.9      
180 63.573.380.590.1     
200 68.580.795.2106.7120.7    
240  89.5102.4122.6137.6140.7   
260   118.7137.6152.4166.8168.5  
280    149.7168.7180.2192.7200.2 
300     183.5200.7218.5231.7 
280      210.6241.7260.5250.5
300      220.9265.5298.8280.7
340       277.7327.7330.2
380       285.6356.7370.7
420         342.2
460         400.1
500         427.7
540         447.2
580         466.5
steel yield depth (mm)90121142185211250280357405501
 

 

 

Processing Method

1 Tools

  • Electric hammer
  • Hole cleaning brush
  • Air compressor
  • Glue gun

2 Attention

  • Drill as per requested hole dia. and depth
  • Clean the hole completely
  • Inject from the bottom of the hole and pull out the gun slowly.
  • After planting the bar, let the gel harden in still.

 

  • Processing Flow

     Drilling: As per technical data

     Cleaning: using pump or compressed air and brush to clean the hole completely.

    Assembling and Injection: Mount the static mixer onto the bottle, push out some incomplete mixed gel at the front part,then inject from the          bottom of the hole, to fill 1/2 to 2/3 depth of the hole.

    Bar planting: spin slowly the bar or screw into the hole, adjust up and down for several times to make the gel average, but don’t touch it during hardening time.

    Curing and Maintenance: According to the temperature of the base materials, give enough time to harden and start to load mounting until it        hardened completely.

 

Curing time:

 

Operation and Harden time
Temperarure -501020≥30
Operation time (min)6045302520
Harden time (h)724824126

 

 

Consumption Chart (holes per cartridge)

 

Anchor Rod dia.M10M12M16M20M24
Drilling Dia.(mm)1214182428
Depth (mm)90110145180220
Each usage8ml13ml28ml62ml103ml
360ml4527   
390ml48301463
585ml73452095
650ml815023106
 

 

 

Packaging:

  • One cartridge with one mixer in carton
  • 12pcs/20pcs/30pcs per carton.
  • Xinchor label or your own label.
  • EXP Date on the top of cartridge.
  • Customized Packing.
Item No.MixingStandard Pack/SetPcs/CtnCtn Size (cm)Ctn/PalletPallets/ 20'FCLPallets/ 40'FCL
FixingChor 1365:1360ml+ 1mixer2027x27x27601020
FixingChor 1393:1390ml+ 1mixer2040x26x27501020
FixingChor 1583:1585ml + 1mixer1229x21.5x30641020
FixingChor 1401:1400ml+ 1mixer3049×30×26401020
FixingChor 1651:1650ml+ 1mixer1031.5×21×26701020
FixingChor 1422:1420ml + 1mixer2046x22x23401020

 

Shipping:

  • Shipments can be arranged by sea, air, courier express.
  • Courier express includes DHL, FedEx, TNT, UPS, EMS, SF, etc.

Hot Products

55KN Modified Pure Epoxy Adhesive Anchoring System Edge Sealing​ Anchoring Adhesive used with thread ...
Retrofitting Epoxy Anchor Adhesive , Rebar Epoxy Adhesive Injection Mortar PRODUCT FEATURES -High ...
Long Term Load Stability Adhesive Anchoring System 420ml 2:1 For Thread Rod Chemical anchor adhesive...
Anti Drawing Chemical Anchor Adhesive 1000ml No Expansibility Without Sagging 1000ml 1:1 Cartrige ...
Fast Setting Epoxy Sleeve Anchors Hybrid Mortar No Hole Cleaning Required Advantages/Benefits ...
Anti Corrosion Epoxy Concrete Fasteners Weather Proof Good Thixotropy Alkali Resistant 650ml 1:1 Two ...