Product Details

Chilled water 4 way ceiling cassette type fan coil unit
Air volume=200CFM-1600CFM(340m³/h-2720m³/h)
cooling capacity:1.8Kw--13.2Kw(0.5RT--3RT)
Easy to be installed. Thin design unit which can be installed in a limit ceiling, the thinnest is 290mm
EC motor is standard, DC motor is optional , high efficiency and energy saving.
"C"type heat exchanger, blue fin.
Compact design, suitable for strict space installation.
Driven by a three-speed motor, low noise.
Turbo centrifugal fan. The efficiency of airflow rate,heavy wind volume and low noise is excellent. Because the ventilator wheel is processed to sine strip seam.
Wide angel airflow: 60 degrees from top to bottom. Adopting uniform size with a square, elegant streamline panel.
Luxury shape and ABS panel. Corner cover design makes installation and maintain maintenance.
The drip tray is complete with a drain pump for draining the condensate water.
Remote control.
Fresh air can be input from outdoor to better indoor air quality.
The water remain in the tray is easy to drained by manual.
High efficient copper pipe to wear Hydrophilic aluminum coil.
2 pipes and 2 rows type as standard. 4 pipe is optional.
Water valve inside is optional.
E-heater is optional
External drained pump is optional
Electrostatic dust sanitiser is optional
BMS system is optional

model(2 tube system)MFP-34KM-(Q)MM1MFP-51KM-(Q)MM1MFP-68KM-(Q)MM1MFP-85KM-(Q)MM2MFP-102KM-(Q)MM2MFP-136KM-(Q)MM3MFP-170KM-(Q)MM3MFP-204KM-(Q)MM3MFP-238KM-(Q)MM3MFP-245KM-(Q)MM4MFP-272KM-(Q)MM4
modelFP-34KM-(Q)M1FP-51KM-(Q)M1FP-68KM-(Q)M1FP-85KM-(Q)M2FP-102KM-(Q)M2FP-136KM-(Q)M3FP-170KM-(Q)M3FP-204KM-(Q)M3FP-238KM-(Q)M3FP-245KM-(Q)M4FP-272KM-(Q)M4
model of panelMB-SD11M1MB-SD11M2MB-SD11M3MB-SD11M4
power supply220V,50Hz,1Ph
air volumeHm3/h3805506808801050138017502050220024502720
M300440540700840110014001640176019502040
L23033041053063083010501230132014501360
static pressurePa00000 00000
cooling capacityTHHW200030003800490058007500980011000120001300015000
BTU/h682410236129661671919790255903343837532409444435651180
SHW140022002850350042505500715082509100980011175
BTU/h4777750697241194214501187662439628149310493343838129
THMW17002550325041504950640083509350102001080012450
SHW115018002350285035004550595068507650368509560
THLW140020502600340040005200675076008300890010300
SHW9501400185023002800360047005450600065008400
heating capacityHW31004700590076009000116001520017100186002080024000
MW2650400050006450765098501290014550158001670019900
LW2100315039505100605077501020011450124501250015200
noiseH0PadB(A)3942444246464750515253
power inputH0PaW4050587095130160190210220230
waterflow volumem3/h0.340.510.650.830.991.281.671.872.042.212.55
water pressure droppingkPa1113221825232833424345
dimension of water(in & out)connection pipeinZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"
outZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"
coiltypehigh efficient copper pipe to wear Hydrophilic aluminum coil  
dimension of water drain pipemm¢26¢26¢26¢26¢26 ¢26¢26¢26¢26¢26
net dimensionunitL×W×H mm592*592*242750*750*242840*840*242840*840*292946*946*292
panel650*650*40850*850*40950*950*40950*950*401050*1050*40
net weightunitkg1718182223252627273032
 panel 2.24.256
Testing condition:
2-tube system
Cooling
Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC
Entering/out water temperature: 7ºC/ 12℃
Heating
Entering air temperature: 20ºC
Entering water temperature: 60ºC, Same water flow rate as for the cooling
  

 

model(4 tube system)MFP-34KM4-(Q)MM1MFP-51KM4-(Q)MM1MFP-68KM4-(Q)MM1MFP-85KM4-(Q)MM2MFP-102KM4-(Q)MM2MFP-136KM4-(Q)MM3MFP-170KM4-(Q)MM3MFP-204KM4-(Q)MM3MFP-238KM4-(Q)MM3MFP-245KM4-(Q)MM4MFP-272KM4-(Q)MM4
modelFP-34KM4-(Q)M1FP-51KM4-(Q)M1FP-68KM4-(Q)M1FP-85KM4-(Q)M2FP-102KM4-(Q)M2FP-136KM4-(Q)M3FP-170KM4-(Q)M3FP-204KM4-(Q)M3FP-238KM4-(Q)M3FP-245KM4-(Q)M4FP-272KM4-(Q)M4
model of panelMB-SD11M1MB-SD11M2MB-SD11M3MB-SD11M4
power supply220V,50Hz,1Ph
air volumeHm3/h3605206508401000132016601950209024002720
M290420510670800105013301560167019002040
L22031039050060079010001170125014001360
static pressurePa00000000000
cooling capacityTHHW195029503700480057007350960010800117501260013200
BTU/h670010050127001640019400251003275036800401504299145040
SHW135021502800345041505400700081008900950010000
BTU/h4700735095501170014200184002390027600304503241434120
THMW16502500320040504850625082009150100001052011000
SHW1150175023002800345044505850670075003589437532
THLW13502000255033503900510066007450815087309100
SHW9501350180022502750355046005350590063106600
heating capacityHW195030003750485057507400970010900118501280013500
MW17002550320041004850625082009250100501065011200
LW13502000250032503850495065007300795083408750
noiseH0PadB(A)3942444246464750515253
power inputH0PaW4050587095130160190210220230
waterflow volumeCoolingm3/h0.330.50.640.810.971.251.641.8322.362.2
Heating0.220.330.420.540.640.821.081.211.321.421.5
water pressure droppingCoolingkPa111322182523283342ZG3/4"ZG3/4"
Heating7813111515192326ZG3/4"ZG3/4"
dimension of water(in & out)connection pipeinZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"
outZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"ZG3/4"
coiltypehigh efficient copper pipe to wear Hydrophilic aluminum coil  
dimension of water drain pipemm¢26¢26¢26¢26¢26 ¢26¢26¢26¢26¢26
net dimensionunitL×W×H mm592*592*242750*750*242840*840*242840*840*292946*946*292
panel650*650*40850*850*40950*950*40950*950*401050*1050*40
net weightunitkg19202024.525.527.529.529.5303333
panel 2.24.256
Testing condition:
4-tube system
Cooling
Entering air temperature: Dry bulb 27ºC, Wet bulb 19.5ºC
Entering/out water temperature: 7ºC/ 12ºC
Heating
Entering air temperature: 20ºC
Entering/out water temperature: 60ºC/ 50ºC
  

Hot Products

Chilled water 4 way ceiling cassette type fan coil unit Air volume=200CFM-1600CFM(340m³/h-2720m³/h) ...
Cassete 4 Vias 2 Tubos-1600CFM Chilled water 4 way ceiling cassette type fan coil unit Air volume...
4 way Decorative typefan coils with Modbus function-1600CFM Chilled water 4 way ceiling cassette ...
Meco, CE certification, 4-way flowing water cassettes FCU, 7KW cooling capacity , brushless DC motor...
Detailed Product Description WATER CHILLED ONE WAY CASSETTE TYPE FAN COIL(1-WAY,2 TUBE) 200CFM to ...
Meco, CE certification, Chilled water four way cassette fan coil units, cassette FCU hydronic fan ...