Jiangsu CASI Solar Co., Ltd. |
|
2Volt 1000Ah Deep Cycle Gel Battery Solar System UPS Series
Connection
Description
Deep Cycle Gel battery is a battery in which the electrolyte is in
gel state, which belongs to a development classification of
lead-acid battery, the method is to add gelling agent to sulfuric
acid, so that the sulfuric acid electrolyte becomes gel
state. Composition is different: lead-acid battery is mainly
composed of tubular positive electrode plate, negative electrode
plate, electrolyte, partition, battery tank, battery cover, pole
column, liquid injection cover, etc. The internal structure of gel
battery is mainly SiO2 porous mesh structure with a large number of
tiny gaps, which can make the oxygen generated by the positive
electrode of the battery migrate smoothly to the negative electrode
plate and facilitate the absorption of the negative electrode by
chemistry.
Model | Nominal Voltage | Capacity C10 | Weight | Dimension | ||
Height | Length | Width | ||||
V | Ah | kg | mm | mm | mm | |
JGFM 100-2 | 2 | 100 | 7.2 | 205 | 172 | 102 |
JGFM 150-2 | 2 | 150 | 9 | 320 | 172 | 102 |
JGFM 200-2 | 2 | 200 | 13 | 329 | 171 | 111 |
JGFM 300-2 | 2 | 300 | 18 | 330 | 171 | 151 |
JGFM 400-2 | 2 | 400 | 25 | 329 | 211 | 176 |
JGFM 500-2 | 2 | 500 | 28 | 331 | 241 | 172 |
JGFM 600-2 | 2 | 600 | 35 | 331 | 301 | 175 |
JGFM 800-2 | 2 | 800 | 48 | 333 | 410 | 175 |
JGFM 1000-2 | 2 | 1000 | 62 | 329 | 470 | 175 |
JGFM 1500-2 | 2 | 1500 | 96 | 343 | 401 | 351 |
JGFM 2000-2 | 2 | 2000 | 123 | 343 | 491 | 351 |
JGFM 3000-2 | 2 | 3000 | 180 | 341 | 712 | 353 |
Product Features
Advantages
Application
Compliant standards
Use of Deep Cycle Gel Battery
Discharge: 1) 12V battery charging and discharging, 250Ah battery
with a current of no more than 25A for 10 hours to discharge until
the battery termination voltage of 10.8V or more, do not over
discharge.
2) During the discharge process, measure and record the battery
voltage, discharge current and ambient temperature every hour, pay
attention to the change of ammeter and battery voltage at any time,
when the voltage drops to about 12.0V, change to half an hour test.
When the measured voltage is 10.8v, stop discharging, open the
discharge switch, the discharge is over. And record the discharge
termination time, battery voltage, ambient temperature.
3) After discharge, the battery should be recharged in time, to
prevent acidification of the poles, the discharge-charging interval
should not exceed 8 hours, so it must be balanced within 8 hours to
replenish the electricity, the average charging voltage is set to
14.1V (the average of the measured value of the positive and
negative terminals of the battery at 25℃), and the maximum charging
current is set to 0.25C10A. The battery will run normally with the
float charging voltage of 13.5V. Battery 13.5V.
Temperature compensation: The above current and voltage setting values are the standard values when the ambient temperature is 25℃, if the gel battery working temperature is beyond the range of 20℃-30℃, the floating charge and average charge voltage should be corrected accordingly, the corrected voltage is, that is, for every 1℃ increase in temperature, the floating charge voltage is reduced by 5.5mV, and for every 1℃ decrease in temperature, the floating charge voltage is increased by 5.5mV.