Home Companies Changzhou Bextreme Shell Motor Technology Co.,Ltd

24VDC brushless electric water pump for glycol Coolant Circulation with PWM control

Changzhou Bextreme Shell Motor Technology Co.,Ltd

Contact Us

[China] country

Trade Verify

Address: No.8 Tianshan road, Xinbei district,Changzhou,Jiangsu,China.

Contact name:Amigo Deng

Inquir Now

Changzhou Bextreme Shell Motor Technology Co.,Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

24VDC brushless electric water pump for glycol Coolant Circulation with PWM control

Country/Region china
City & Province changzhou jiangsu
Categories Travel Products
InquireNow

Product Details

DC 24 V 250W automotive Electric brushless motor Water Pump For BEV Bus / PHEV Vehicles coolant circulation

OWP-BL43-300 250W heavy duty electric water pump for electric bus/truck battery and controller cooling system 

Applications:

 

1: electric vehicles cooling system

2: engine,battery,controller,AC coolant circulation

3: industrial cooling system

4: BEV bus,PHEV vehicles

 

 

No.ItemsParameter
1

Medium

temperature range

Max 40% Glycol

-40℃~85℃

2Flow & HeadFlow Q=6000L/H, Head H≥8M
3Noise≤61dB
4Rated VoltageDC24V
5Operating VoltageDC18~32V
6Max Current≤11A
7Power250W±10W
8IP GradeIP68
9Service life≥20000h
10Net Weight1.95kg

 

 

Advantages of our electric water pump

*Brushless Motor assembly efficiency max reach to 85%(normal level 70%),controller driving efficiency max reach to 97%


*Shielded brushless motor,long service life ,low power consumption,compact size, high reliability


*Strong pump development capability , professional Ansys Fluent simulation calculation offering high-efficiency customized development.


*Sinusoidal wave controlling circuit ,EMC proved, Automotive grade electronic components .


*Automatically detect no-load/semi-load state and protective self stop, automatically detect the plugging state and protective self stop, detection overload and protective deceleration operation, positive and negative pole reverse protection function.


*Shielded - type inner - rotor structure , IP grade IP67 , insulation grade F.

 

Structure of electric water pump

 

Simulation calculation of hydraulic design of electric pump

Electric water pump design principle

Electric water pump design verification - electromagnetic theory design verification

Design verification of electric pump product design - test verification

 

 

■ Applications

 

Widely used in hybrid bus, hybrid passenger car, electric vehicles, trains, ships and other heating and cooling circulation system.

 

■ Features

◆Centrifugal pump

◆Magnetic force transmission

◆High efficiency brushless DC motor, low power consumption, high efficiency, long service life.

◆With wide range operating temperature

◆PWM signal speed controlling(optional)

◆Diagnostic signal output(optional)

◆With constant flow controlling

◆Reverse polarity protection

◆Dry running protection

◆Over Voltage, over current protection

◆Overload, over temperature protection

 

■ Technical description (related parts in contact with the liquid)

Pump head housing: Aluminum alloy

Impeller: PPS+GF

Shield cavity: PPS+GF

Shaft sleeve: carborundum composite materials

Shaft: stainless steel(3CR14) shaft

Magnet housing: PPS plastic capsulation

Seal ring: EPDM

 

■ Driving device (Including motor)

Driving rotor: PPS plastic capsulated magnet

Screws and nuts: SUS 304 stainless steel

Driving Motor : brushless motor

Motor wire frame :PPA GF

Pump housing: Die-casting aluminum case with sandblasting and anodizing +PE powder coating..

 

Bracket: Steel base

Bracket hoop: US 304 stainless steel

Waterproof based on IP68 rating (en60529)

Connector model: AMP282104-1 (matched Plug AMP282080-1)

Nozzle diameter:40mm (1.5 inch)

 

 

Mounting instruction

OWP-BL43-300 series pumps are centrifugal pumps which require pre-filled,

The pump installed in the lowest position of the system to ensure that the impeller is always immersed in the liquid, or pre-filled the pump before power on .

1: Pump should not be dry-running, even though it can dry-running for 15 minutes (after 15 minutes dry-running, it will automatically stop), Dry running will makes noise, also increasing abrasion to the shaft and shaft sleeve.

 

2:Use the recommended diameter pipe connecting the pump inlet, if you use a smaller diameter hose pump inlet, Due to the negative pressure in the pump, the outside air easier enter to the pump through the pipeline, it will make the pump performance degradation, and also the air bubbles make damage to the pump.

 

3: As viewed from the pump inlet direction, the impeller rotates clockwise (see the arrow on the outlet port).

 

4: The pump can be installed vertically or horizontally mounted (see figure 1 ) When installed vertically, the outlet port should be upward .

 

5:In order to avoid the dry- running (air get stuck in impeller),the water pump outlet port should be vertical or in the upper of the impeller. (see figure 1 )

 

6: The connected pipe should be vertically mounted (or no elbow in 20cm )to make the air discharged easily, the outlet pipe should not be used less than 90 degrees elbow (see figure 2).

 

7: Can't use the seawater or other heavy pollution with big grain impurity liquid as the liquid medium .

 

figure 1 figure 2

 

 

■ Temperature parameter

Medium liquid temperature: -40℃ to +85℃ (-40°F to + 185°F)

Working ambient temperature: -40℃ to +120℃ (-40°F to +248°F)

Storage temperature: -40℃ to +70℃ (-40°F to +158°F)

(up to 100 ℃, but it will shorten the service life)

System pressure

-0.2 to 2.5 bar ( 100℃ (212°F).

The service life is more than 20,000 hours based on the rated voltage and 36℃(86°F) ambient temperature.

Voltage range

Rated 24V water pump, workable range 18V - 32V

Although the motor can be used in a wide range of voltage and temperature, but excessive or too low voltage and temperature will affect the service life of the motor, the pump can not be exposed to thermal radiation ambient.

 

Medium liquid: liquid mixture (Water with below 60% glycol)

 

■ Electrical parameter

 

Working Voltage

(VDC)

Rated power

 

Rated flow

(L/H)

Dimensions

(mm)

Weight

(g)

18V-32V(24V)130WQ=5000L/H, H≥5m195*90*1451950g
200WQ=6000L/H, H≥6m
250WQ=6000L/H, H≥8

 

 

 

 

 

 

 

 

 

 

 

 

 

Connector model and the corresponding electrical properties (see figure 3):

AMP282104-112
(matched Plug AMP282080-1)+24V DCGND

 

 

 

 

 

 

Wire thicknessThe longest wire used *
 24V
1.5 mm²16m
2.5 mm²25m
3 mm²31m
4 mm²40m

 

 

 

figure 3

 

 

 

 

Recommended Wire size is (Based on 3% voltage drop)

* The length of the wire means the distance from pump to the battery

 

 

Attentions

1. Working ambient temperature:-40℃--120℃, should try to avoid close to three-element catalytic, gas discharge pipe system and engine during the installation, ensure the working environment temperature.

2.The installation position of the water pump should as much as possible close to the low water level , to extend the service life of the pump.

4. Please use the pump far from the dusty environment, the dust is harmful to reduce the service life

5. Pay attention to the purity of the water, avoid to jam and impeller-blocked to reduce the service life of pump

 

Performance parameter

 


  • External dimension

 

 

Hot Products

12VDC 500W PWM speed control Hall effect BLDC motor driver JYQD-V7.3E3 MODEL:JYQD-V7.3E3 OPERATING ...
24VDC 3A current compact size JYQD-V6.7 BLDC motor driver for sensorless BLDC motor Model number ...
PWM speed control 36-72VDC JYQD V7.5E 3 Phase BLDC Driver Board for Hall sensored motor Overview ...
PWM 100 to 20KHZ 24VDc 3 Phase Brushless sensorless Motor Driver Controller Circuit Board for ...
12-36VDC 15A 3 Phase BLDC Motor dual Driver/controller For Wheelchair / Electric Skateboard Overview ...
JYQD-V7.3E2 3 Three Phase BLDC Driver Board 15A 12-36V For 42mm 57mm BLDC motor Overview Quick ...