Home Companies Guangzhou BioKey Healthy Technology Co.Ltd

Real Time HPV PCR Kit Dectect High Risk Genotyping HPV Virus Taqman Probe Assay

Guangzhou BioKey Healthy Technology Co.Ltd

Contact Us

Trade Verify

Address: Add:No.2, Ruitai Rd, Guangzhou Hi-Tech Industrial Development Zone, 510670, CHINA

Contact name:Lisa

Inquir Now

Guangzhou BioKey Healthy Technology Co.Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Real Time HPV PCR Kit Dectect High Risk Genotyping HPV Virus Taqman Probe Assay

City & Province guangzhou
Categories Dyestuff Intermediates
InquireNow

Product Details

Real Time quantitative PCR High risk Human Papillomavirus ( HPV ) Nucleic Acid Taqman DNA Detection Kit 

 
Intended use:
 

This kit, adopting Real-Time PCR-Fluorescence technology, is used for qualitative detection of HPV 16+ 18, which usually causes cervical cancer for women. Thus this PCR assay can be used for the laboratory diagnosis and monitoring of the virus infection. The test results are only for clinical reference, not for case confirmation or exclusion.

 

Test Principle:


The specific primers and specific fluorescent probes are designed for the conserved region of HPV 16+ 18. The PCR reaction solution, and real-time fluorescent quantitative PCR detection technology is applied on the fluorescence quantitative PCR instrument to realize the rapid detection of HPV 16+ 18 through the change of fluorescence signal. The detection system contains a human internal control (IC) gene, which is used to monitor whether the specimens and the process of the nucleic acid extraction is qualified.


Product components:

 

No.ComponentsBIK-QL-H005
1PCR Enzyme Mix (Lyophilized)96 tests/bottle
2HPV Primer-Probe Mix100 μL/vial
3Enzyme Mix Buffer (5×)400 μL/vial
4Positive Control100 μL/tube
5Negative Control100 μL/tube
6RNase-free water1mL/tube
7Paraffin oil1.5mL/tube*2

 

Note: Do not mix the components from different batches for detection. The Positive Control of HPV and internal control were constructed artificially, and they were not infectious.

 

Data anlysis:

 

The following sample results are possible:

 Ct valueResult Analysis
1#No CtNegative
2#≤38Positive
3#38~40Re-test; if it is still 38~40, report as 2#

 

Reaction mix preparation :

 

Refer to one of the table below to prepare the reaction mix:

 

1×volume required
Resuspended master mix14 μL
HPV Primer-Probe Mix1 μL
Total volume15 μL

Multiply the numbers according to the number of tests.

 

Interpretation of test results:

 

 FAM (HPV16)VIC/HEX (HPV18)ROX(IC)Interpretation test results
1---Result invalid, test again
2+-+/-HPV16(+)
3-++/-HPV18(+)
4+++/-HPV16 and HPV18(+)
5--+Negative(-)

NOTE: ‘+ ’ is positive, ‘- ’ is negative.

 

 Operation details please check from IFU

Hot Products

Respiratory Syncytial Virus/Influenza B/Influenza A RT-PCR test kit (Lyophilized) --48 tests/kit ...
HPV Genotype 2+12 High risk(16+18)+Medium risk Real Time PCR Detection Kit (Lyophilized) --48 tests...
Real Time quantitative PCR High risk Human Papillomavirus ( HPV ) Nucleic Acid DNA Detection Kit ...
Real Time quantitative PCR High risk Human Papillomavirus ( HPV ) Nucleic Acid Taqman DNA Detection ...
Human Papilloma Virus HPV 16 / 18 genotype RT PCR Fluorescence probing PCR test kit Intended use: ...
Multiplex Genotype HPV 16 + 18 Real Time Fluorescent PCR Detection Kit (Lyophilized) Intended use: ...