KingPo Technology Development Limited |
Verified Suppliers
|
|
Conform to EN 60598-1 clause 9.2
Where connection is made by a plug or a similar device, then this
shall be regarded as part of the complete luminaire and shall be
included in the tests and similarly for any separate controlgear.
For tests of 9.2.3 to 9.2.11, a fixed luminaire intended for
mounting with its body in contact with a surface shall be tested
with an expanded metal spacer interposed between the luminaire and
the mounting surface. The spacer shall be at least equal in overall
size to the projection of the luminaire, and have dimensions as
follows:
Longway of mesh 10 mm to 20 mm
Shortway of mesh 4 mm to 7 mm
Strand width 1.5 mm to 2 mm
Strand thickness 0.3 mm to 0.5 mm
Overall thickness 1.8 mm to 3 mm