KingPo Technology Development Limited |
Verified Suppliers
|
|
Aviation Power APA5000 Series(AC)
Product parameter
• LED / LCD display, clear and intuitive
• Higher power density, smaller size, lighter weight, space saving
and easy to move
• The protection level is as high as IP54, and the whole machine
parts are treated with three preventive measures. working
temperature-40℃~50℃
• There are two types of aircraft, vertical type and Trailer type,
which are convenient for airport/hangar moving or fixed-point use.
• Excellent overload capability and optional extended overload
function
• More detailed protection function, can detect
under-voltage/over-voltage, over-current, over-load,
over-temperature, short circuit and other fault states.
• Inspection of temperature and humidity in the machine to ensure
the normal use of power supply
• Three-phase power supply can withstand three-phase unbalanced
load: 120° +1°; 30% unbalanced load 120° +1.5°; 100% unbalanced
load 120° +2°.
High Performance
• Optional dual output, suitable for multi-load applications
• Quick stop output with emergency stop button
• With EF signal interlocking function
APA5000(AC)Single phase series
Model | 5000 | 5001 | 5002 | 5003 | 5005 | 5015 | 5020 | 5030 |
---|---|---|---|---|---|---|---|---|
Output Capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 15KVA | 20KVA | 30KVA |
Input Power | 1Ø2W+G 110V/220V±10% | 3Ø4W+G 220V/380V±10% | ||||||
50/60Hz±3Hz | ||||||||
Output Frequency | Vertical/trailer type 300~ 500Hz 400Hz (Special frequencies are customized) | |||||||
Output Voltage | 115V/220V±10%(Special Voltage Accepts Customization) Resolving power 0.1V accuracy 0.5%F.S.+4counts | |||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 126/63 | 168/84 | 250/125 |
Resolving power0.01A(500VA,1KVA) 0.1A(1KVA以上) accuracy 0.2%F.S.+4counts | ||||||||
Load Regulation | ≤1%(Resistive load) | ≤1.5% (Resistive load) | ||||||
Waveform Distortion | ≤2%(Resistive load) | ≤3% (Resistive load) | ||||||
Meter Display | LED/LCD Display | |||||||
Protective Device | Input and output are equipped with no fuse switch, overload, over-current, temperature, short circuit, over-voltage/under-voltage protection and alarm | |||||||
Overload capacity | 120%(1H)150%(1M)200%(15S)Other specifications are optional (According to 25% work cycle Duty Cycle Test results) | |||||||
Weight(kg) | 20 | 25 | 30 | 35 | 45 | 190 | 240 | 3500 |
W*H*D(mm) | 425*89*480 | 430*200*500 | 430*580*700 | 600*1260*700 | ||||
Working condition | ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable) |
APA5000S(AC)Three phase series
Model | 5015S | 5020S | 5030S | 5045S | 5060S | 5075S | 5100S | 5120S |
---|---|---|---|---|---|---|---|---|
Output Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 100KVA | 120KVA |
Input Power | 3Ø4W+G 220V/380V±15% | |||||||
50/60Hz±3Hz | ||||||||
Output Frequency | 400Hz(Trailer type)/300~ 500Hz (Vertical type)Resolving power 0.01Hz accuracy±0.02%F.S. | |||||||
Output Voltage | 115/200V±15V Resolving power 0.1V accuracy 0.5%F.S.+4counts | |||||||
Output current | 42/21 | 54/27 | 84/42 | 126/63 | 168/84 | 210/105 | 278/139 | 333/166 |
Resolving power 0.1A accuracy 0.5%F.S.+4counts | ||||||||
Load Regulation | ≤1%(Resistive load) | |||||||
Waveform Distortion | ≤2% (Resistive load) | |||||||
Meter Display | LED/LCD Display | |||||||
Protective Device | Over-voltage/under-voltage phase-gap protection and alarm with
overload, over-current and over-temperature short circuit | |||||||
Overload capacity | 125%(600S)150%(30S)200%(10S)Other specifications are optional | |||||||
(kg)Weight | 210 | 230 | 270 | 360 | 450 | 540 | 600 | 800 |
(mm)W*H*D | 510*780*710 | 600*1260*700 | 750*1500*850 | 900*1780*950 | ||||
Working condition | ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable) |
Customized Services
To fulfill the diversified needs for clients, we gain experience of
research and achieve flexible production.
Standard Mastery
Extensive experiences of customized business and understanding of
each standard.
Thorough Services
Serving with a grateful, professional and honorable attitude, we
established our own independent service branch to provide you with
long-term value adding services.
Experienced R&D Team
Extensive experiences of Research and Development for mechanics,
electronics, optics, thermology, IT technology and customer
services.
Overall Matching
Solutions provider for laboratories based on standards or functions
required.
Company Profile
KINGPO company extensive research and development experiences
regarding safety performance testing, electromechanical properties
testing, fireproof and flame retardant performance testing,
waterproof performance testing and life testing for the household
electrical appliances, electronic and electrical products,
electrical accessories, building components and materials, wire and
cable, IT computer and communications, children's toys and
textiles, power simulate load and capacitor and so on.
Also manufacture the testing equipment for all kind of products,
sampling laboratory and line automatic detecting system.
With the nationally recognized testing instrumentation production
license. More than 1000 kinds of products.
packaging & shipping
Packaging: Wooden Box
Shipping: ocean
Port: Shenzhen port or Customer's required
Payment & Delivery
Payment method: T/T, money Gram, Paypal, Western Union
Payment currency: USD, HKD, CNY
Delivery: 10-40 days received the deposit.
FAQ
Why choose us?
Customized Services
To fulfill the diversified needs for clients, we gain experience of
research and achieve flexible production.
Standard Mastery
Extensive experiences of customized business and understanding of
each standard.
Thorough Services
Serving with a grateful, professional and honorable attitude, we
established our own independent service branch to provide you with
long-term value adding services.
Experienced R&D Team
Extensive experiences of Research and Development for mechanics,
electronics, optics, thermology, IT technology and customer
services.
Overall Matching
Solutions provider for laboratories based on standards or functions
required.
KingPo testing equipment(DONGGUAN) Co., Ltd is engages and
specialized in testing equipment with good quality and pretty
competitive prices for more than 20 years, belonging to the
high-tech enterprises. We always pursue the perfection with you.
What kind of your corporation?
We're the China testing machine manufacturer and trader.
What's your delivery time?
Normally, it is 10-40 days according to the unload port.
Contacts
KingPo testing equipment(DONGGUAN) Co., Ltd Tel: +86-769-81627526 Fax: +86-769-89032367 Email: info@kingpo.hk Add: No. 9 University Road, Songshan Lake, Dongguan City 523770,
China |
TAG: iec tester, laboratory test equipment,iec testing equipment
High Performance
• Optional dual output, suitable for multi-load applications
• Quick stop output with emergency stop button
• With EF signal interlocking function
APA5000(AC)Single phase series
Model | 5000 | 5001 | 5002 | 5003 | 5005 | 5015 | 5020 | 5030 |
---|---|---|---|---|---|---|---|---|
Output Capacity | 500VA | 1KVA | 2KVA | 3KVA | 5KVA | 15KVA | 20KVA | 30KVA |
Input Power | 1Ø2W+G 110V/220V±10% | 3Ø4W+G 220V/380V±10% | ||||||
50/60Hz±3Hz | ||||||||
Output Frequency | Vertical/trailer type 300~ 500Hz 400Hz (Special frequencies are customized) | |||||||
Output Voltage | 115V/220V±10%(Special Voltage Accepts Customization) Resolving power 0.1V accuracy 0.5%F.S.+4counts | |||||||
Output current | 4.2/2.1 | 8.4/4.2 | 16.8/8.4 | 25/12.5 | 42/21 | 126/63 | 168/84 | 250/125 |
Resolving power0.01A(500VA,1KVA) 0.1A(1KVA以上) accuracy 0.2%F.S.+4counts | ||||||||
Load Regulation | ≤1%(Resistive load) | ≤1.5% (Resistive load) | ||||||
Waveform Distortion | ≤2%(Resistive load) | ≤3% (Resistive load) | ||||||
Meter Display | LED/LCD Display | |||||||
Protective Device | Input and output are equipped with no fuse switch, overload, over-current, temperature, short circuit, over-voltage/under-voltage protection and alarm | |||||||
Overload capacity | 120%(1H)150%(1M)200%(15S)Other specifications are optional (According to 25% work cycle Duty Cycle Test results) | |||||||
Weight(kg) | 20 | 25 | 30 | 35 | 45 | 190 | 240 | 3500 |
W*H*D(mm) | 425*89*480 | 430*200*500 | 430*580*700 | 600*1260*700 | ||||
Working condition | ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable) |
APA5000S(AC)Three phase series
Model | 5015S | 5020S | 5030S | 5045S | 5060S | 5075S | 5100S | 5120S |
---|---|---|---|---|---|---|---|---|
Output Capacity | 15KVA | 20KVA | 30KVA | 45KVA | 60KVA | 75KVA | 100KVA | 120KVA |
Input Power | 3Ø4W+G 220V/380V±15% | |||||||
50/60Hz±3Hz | ||||||||
Output Frequency | 400Hz(Trailer type)/300~ 500Hz (Vertical type)Resolving power 0.01Hz accuracy±0.02%F.S. | |||||||
Output Voltage | 115/200V±15V Resolving power 0.1V accuracy 0.5%F.S.+4counts | |||||||
Output current | 42/21 | 54/27 | 84/42 | 126/63 | 168/84 | 210/105 | 278/139 | 333/166 |
Resolving power 0.1A accuracy 0.5%F.S.+4counts | ||||||||
Load Regulation | ≤1%(Resistive load) | |||||||
Waveform Distortion | ≤2% (Resistive load) | |||||||
Meter Display | LED/LCD Display | |||||||
Protective Device | Over-voltage/under-voltage phase-gap protection and alarm with
overload, over-current and over-temperature short circuit | |||||||
Overload capacity | 125%(600S)150%(30S)200%(10S)Other specifications are optional | |||||||
(kg)Weight | 210 | 230 | 270 | 360 | 450 | 540 | 600 | 800 |
(mm)W*H*D | 510*780*710 | 600*1260*700 | 750*1500*850 | 900*1780*950 | ||||
Working condition | ambient temperature -40℃~50℃ relative humidity 0~90% (Non-condensable) |