Chapter one: introduction of the instrument

1.1 Characters and main use

This tester is used to perform the fatigue test on the AC and DC power cord and power cords lead. This is the necessary equipment for the QC department and Lab of the related industry.

The rotating speed and rotating angle can be preset freely, and it will alarm once the specimen was damaged, it has many good features, such as: high accuracy, stable, and high efficiency, which is a perfect tester for fatigue test.

1.2 Design standards

UL817, IEC60884, VDE0620, GB2099 and so on.

1.3 Technical Parameter

Series noItemparameter
1Input power220VAC±10%,50/60Hz
2Fuse5A/250VAC
3Output power1000W
4Cores of the specimen2—5 Cores
5Working channel1
6Flexing angle range50-9999°can be adjusted)
7Flexing precision+/- 1 °
8Rotating speed5-60 cycle/min(can be adjusted)
9Test times range0-999999
10Counter precision+/- 1 times
11Weight1 kgs/2 kgs(can be equipped according to requirement)
12Failure alarmThe machine will alarm and the touch screen will have indication once the specimen is damaged.
13Qualified indicationThe machine will alarm and the touch screen will have indication once the real testing times meet the preset test times.
14Outer dimension200*300*500(L*W*H)
15Net weightApproximately 10 Kgs

 

Chapter two: installation introduction

2.1 Mounting and dismounting noticeable points

2.1.1 Check the instrument if damaged in transit;

2.1.2 Check the instrument if invert;

2.1.3 Check if the specification on the nameplate of the instrument accord with your order;

2.1.4 Check if the packing list accord with real object.

If above abnormal happened, please don’t use this instrument, and timely to contact with agency or our company.

 

2.2 Safety rule

2.2.1 Before using this machine, please read manual in depth, learn related safety signs and operation steps, to ensure safety.

2.2.2 Check if the real power supply accord with it in nameplate and make sure the power well grounded.

2.2.3 Layperson forbidden to open the door or rear cover of the machine, to avoid electric shocking.

2.2.4 Instrument screen cannot be scraped by sharp objects.

2.2.5 User cannot modify the circuits or elements, otherwise the guarantee will be invalided, caused any consequences will not be afforded.

2.3 Installation requirement

2.3.1 The instrument should be placed on horizontal and fixed work stations.

2.3.2 the instrument used ambient temperature should be 25±10℃, related humidity 50±30%RH

2.3.3 The instrument should be far away from heat source and corrosion source.

2.3.4 The instrument should be have well grounded power supply AC 220V/50Hz±10%.

 

Instrument picture

                                

 

Front panel

 

Side panel                            

 

 

 

 

Hot Products

DIN-VDE0620-1 Plug And Socket Gauge For Measuring German Standard Plug And Socket Product informatio...
G10q , GX10q, GY10q,GZ10q Lamp cap gauge , "GO" GAUGE FOR CAPS C G10q, GX10q, GY10q , GZ10q GO" ...
ISO 8124-1 2014 Stainless Steel Protrusion Test Gauge Technical Parameter Material Stainless steel ...
IEC 62368 Edition 3, CDV Steel Disc, Aluminium Ring And Aluminium Foil For Wireless Charge The ...
Zhaga book 18 -Annex B Mechanical drawing of the Mechanical-stop-gauge 5.1.1 Mechanical-stop-gauge ...
IEC 62368 Edition 3 Figure 47 Figure 48 Figure 49 Foreign Metallic Objects with Insulation Board for ...