Charging Volt | Series*4.25V | Discharge Current :Same as bms current | Charge current | :Depends on specification |
Overcharge protection | 4.25+0.025V | Detection Delay: 1000+500ms | Release Volt | 4.15+0.05V |
Overdischarge protection | 2.75+0.1V | Detection Delay: 1000+500ms | Release Volt | 3+0.1V |
Balance Function | 4.15+0.025V | Detection Delay: 100+50ms | Balance Current | 42+5MA |
Overcurrent Protection | 50+15mv | Detection Delay: 1000+500ms | Current protection | 300+50A 450+50A 600+60A |
Short circuit protection | YES | Detection delay | 300us | Off load |
| Charging temp: 55 degree | Discharging temp 75degree | Release method | Temperature recover to normal charging temp |
Self consumption | Working <35ua | Rest <10ua | Working Temp | -30 to 80 degree |