Home Companies Shenzhen XUWEN Technology Co.,Ltd

Smart Ant LTO Battery BMS 10S-24S 450A 300A 200A For Li Polymer Battery

Shenzhen XUWEN Technology Co.,Ltd
Active Member

Contact Us

[China] country

Address: 4 Floor, Building 8, Yujingtai Industrial Park, 35 Huaxing Road, Shenzhen, Guangdong, China

Contact name:Cathy

Inquir Now

Shenzhen XUWEN Technology Co.,Ltd

Smart Ant LTO Battery BMS 10S-24S 450A 300A 200A For Li Polymer Battery

Country/Region china
City & Province shenzhen guangdong
InquireNow

Product Details

10S-24S 450A 300A 200A 100A 70A Li-ion Li-polymer LiFePO4 LTO Battery BMS Protection Circuit Board Smart Ant BMS

 

Product introduction:
Support :
10S -24S li-ion battery (30V-102V Lithium battery cell)
13S -24S lifePo4 battery (30V-88V Lithium iron phosphate battery cell)
15S -24S LTO battery (30V-68V Lithium titanate battery cell)
The default is the li-ion parameters. when you phone connect bluetooth , can click and set up lifePo4 / LTO parameters. default setting is 24S , if you use for other number of cells , change it in app .
Single cell voltage detection range 1V-4.6V. High precision detection cell voltage error is less than 5MA
Charging current: 50A
Discharge current: 70A 100A 150A 200A 300A to choose
Balance current :200MA . Controlled balance mode, when the charging is started, the voltage difference can be detected by the
detected voltage difference to be greater than the set value.
High-precision coulomb counter function temperature control detection Hall speed measurement

Bluetooth connection : support for android & IOS phone
Support cells :Support Li-ion , Lipo , 18650, Lifepo4 , LTO and so on
Voltage accuracy :Single cell voltage detection range (1.5-4.6V), so support a variety of cell use, accuracy error within 3 mV
Drop wire protection :detect wire not weld well and cause the voltage is wrong.balance wire drop cell protection
Overcharge protection: Connect to Bluetooth to set high-precision detection voltage, single overcharge protection and total voltage overvoltage protection
Over discharge protection : Connect Bluetooth to set up high-precision detection voltage, single-cell over-discharge protection and total voltage under-voltage protection
Short circuit protection: Can be connected to Bluetooth to set the short circuit protection value, change to 0 is turn off short circuit protection
Overcurrent protection: can be connected to Bluetooth to set up the overcurrent protection value (maximum 300A)
Current detection: within the current range of the purchased protection board
Temperature control protection: The protection board has built-in balanced temperature control, power temperature, and can be connected with 4 temperature controls to prevent high temperature danger.
balance current: 200 mA, high voltage versus low voltage discharge balance
Discharge current: refer to the current in the purchase selection as the peak discharge current
Coulomb counter: compensation 1-24S battery connection between the chip resistance is too long, causing the wire resistance to be too large, the cell voltage is too large during the charging and discharging, can not be used normally
Connection internal resistance: based on current to time scoring, accurately calculate the remaining battery capacity and charging current

 

 

RFQ

1.What is the common port and separate port? what is the difference?
We take 13S 48V 15A BMS as an example, common port 15A means your charge cathode and discharge cathode are connected in the same point end(our P-), charge cathode and discharge cathode are used in the common connection
port, so the charge current and discharge current are the same 15A. while the separate port is separately connected by charge cathode (C-) and discharge cathode (P-), so the charge current and discharge current are different, discharge current 15A, charge current 8A.

2.What is the balance function?
The working principle and function are as followings, when your one cell voltage is upto alarm voltage(Li-ion upto 4.18V, LifePo4 upto (3.6V), then the cell Balance starts to work, balance resistance starts discharge with 35ma(when balance discharge starts to work, BMS will starts a little heat up, which is the normal reflection), the cell is in both charging and discharging status, and others which are not reached to alarm voltage(Li-ion 4.18V, LifePo4 3.6V)are only in charging status, no discharging, when the fast cell voltage is reached to alarm voltage (Li-ion 4.25V, LifePo4 3.75V) BMS starts off power protection, all the other cells are all in stop of charging, this process will enable your battery charging in balance current, and your battery voltage are in balance status, but when your cell voltage difference are in a big range, then balance can not be functionning well

3.The relationship between Battery capacity and BMS current?
There is no direct relationship between Battery capacity and BMS current, big capacity doesn`t mean a big battery, but rely on continue current, that is to say if your engine is powerful, your should choose high current of BMS, it is not relied on battery capacity.

4. What type of charger should I choose?
Lithium battery must choose specific charger, do not use Charger for Leadacid battery, for leadacid charger may have MOS with high pressure breakdown protection, which will not protect of BMS over charge. Life Po4 battery charger voltage=battery string No.X3.6V, while Li-ion battery charger voltage=Battery string No.X4.2V.

5. What current BMS should I choose ?
Take 10S 36V as an example: what current BMS you choose is relied on your E-bicycle Motor power and current limitation of controller. eg., choose 15A for below 350W, 20A for below 500W, 30A for below 800W, 60A for Below 1000W, higher than 1200W are contact with our service specialist for suggestions, one inall, continue current shall be higher than current limitation in Controller.

6. Whether my BMS damaged?
if you want to judge if the BMS is damaged, please take the folowing steps, to test if each cell voltage is the same with
voltmeter? if the cell voltage difference is over 1.0V, the fault is displayed that it cannot run far, no power supply at the
start range, short charge time, all these issues are almost caused by battery cells, if BMS damaged is displyed as no charge, no discharge, no discharge while the battery has voltage.

 

 

Hot Products

Rectangular 11.1V LTO Battery BMS 3s 7a Li-Ion Battery Packs Bms Boards Battery Balancer Pcb Design ...
Auto Started Instantly LTO Battery BMS PCM 5S 12V 30A Lithium Titanate Battery Bms For Electric ...
18.5V 30A 5S LTO Battery BMS lithium ion battery pack lto bms for 18V battery pack Features: 1) high...
Active Balance12S-20S 60A Smart LTO Battery BMS Built-In BT Bms For Li Ion Lifepo4 LTO Battery Pack ...
10S-24S 450A 300A 200A 100A 70A Li-ion Li-polymer LiFePO4 LTO Battery BMS Protection Circuit Board ...
8S~20S 40A 80A 150A 300A 400A Lithium Lifepo4 LTO Battery BMS Smart Bms Ant Bms With LCD Screen ...