Home Companies Xiamen Sincery Im.& Ex. Co., Ltd.

1us Response 200A Magnetic Balance Hall Current Transducer

Xiamen Sincery Im.& Ex. Co., Ltd.
Active Member

Contact Us

[China] country

Address: 415 Xincheng Building, No.16 Qishan Road, Huli District, Xiamen Fujian, China

Contact name:Elaine

Inquir Now

Xiamen Sincery Im.& Ex. Co., Ltd.

1us Response 200A Magnetic Balance Hall Current Transducer

Country/Region china
City & Province xiamen fujian
InquireNow

Product Details

NT208-S/SP1 Current Sensor

Product Details

product manual

The magnetic balance Hall current sensor is suitable for accurate measurement of AC, DC and pulsating current isolation. The primary side and the secondary side are completely insulated during measurement.

 

product advantagesApplicationsReference standard
High precisionAC inverter ACEN50178
EN50155
Good linearityBattery powered
Low temperature driftConverter/Inverter
BroadbandUPS/SVG
Quick response 

 

Main electrical parameters
Rated measuring current IPN (A)200
Measuring range IP (A)0~±300
Turns ratio1:2000
Power supply voltage VC (V)+/-12V~+/-15V(+/-5%)
Rated measurement output ISN (mA)100mA
Measuring resistance RM (Ω) 

 

RMmin RMmax

@ ± 12V, ± 200A: 0Ω ~ 50Ω

@ ± 12V, ± 300A: 0Ω ~ 26Ω

@ ± 15V, ± 200A: 0Ω ~ 73Ω

@ ± 15V, ± 300A: 0Ω ~ 40Ω

Secondary side current consumption IC (@±24V)≤20mA+
Isolation withstand voltage6kVrms/50Hz/1min

 

Accuracy-dynamic parameters
Basic error δi
(@IPN,TA=25℃)
≤±0.5%
Linearity δL
(@IPN,TA=25℃)
≤±0.1%
Zero output current IO
(@IP=0, TA = 25℃)
≤ ± 0.2mA
Zero temperature drift IOT± 0.6mA (-25 ℃ ~ + 85 ℃)
Response time≤1µS
di/dt accuracy>50A/us
Frequency bandwidth BWDC..100kHz

 

General data
Working temperature Ta-25℃~+85℃
Storage temperature Ts-40℃~+90℃
weight≤100g

 

Mechanical characteristics
No tolerance±1 mm
Sensor installation method one (recommended)

2hole ø4.2mm

2 M4 steel screws

Sensor installation method two (recommended)

2 hole ø 5.4mm

2 M5 steel screws

Recommended torque2.5 N·m
Busbar size (recommended)Ø15mm
Secondary side electrical connectionThree core pressure coupling

 

 

 

 

 

Remarks
1. When the measured current direction is consistent with the direction marked on the sensor, the sensor output ISN is positive.
2. The secondary side connection line of the product is preferably a shielded line. The shielding layer is close to the product end and the connection line can be connected to the case, and the negative power supply or power supply 0V.
3. The verticality requirements for the mounting screw holes of the power sensor: it is required to be level 8 or above (or below 0.06) in the national standard.
4. The flatness requirements for the installation surface of the power sensor:
(a). The flatness of the large plane installation is national standard 11 or above (or the flatness is less than 0.25mm);
(b). The flatness of the installation surface is designed with small round bosses It is required to reach the national standard level 12 or above (or the plane fluctuation is less than 0.5mm);
5. No tolerance ±1mm is noted;

Hot Products

NACA.XXXB-S5 / VA Current Transducers Product Details product manual NACA XXXB-S5/SP2VA series ...
NACL-1000B-S1 / SP2 Current Transducers Product Details product manual NACL-1000B-S1/SP2 magnetic ...
NACL.300B3-S5 / SP2 Current Transducers Product Details product manual The NACL.300B3-S5/SP2 series ...
NT108-S/SP1 Current Transducers Product Details product manual The magnetic balance Hall current ...
NT208-S/SP1 Current Sensor Product Details product manual The magnetic balance Hall current sensor ...
NT308-S/SP5 Current Sensor product manual The magnetic balance Hall current sensor is suitable for ...