MOORE AUTOMATION LIMITED |
Verified Suppliers
|
|
LYA010A HITACHI analog input module
⇒ Click here for good price LYA010A
Brand/Manufacturer | HITACHI/USA |
Part Number | LYA010A |
Alternate Part Number | LYA010A |
Description | analog input module |
Dimennsions | 15.9cm x 11.4cm x 4.0cm |
Weight | 0.59kg |
Product Details
The function of the HBU braking unit is to divert into a braking
resistor the regenerative energy produced in the process of
decelerating the motor, converting that energy into heat.
Regenerative energy flows from the motor into the inverter DC Bus,
manifested as increased bus voltage. The advantage gained using the
HBU is improved braking performance and shorter deceleration time
of the load.
Before you use the HBU braking unit, please read through this
manual and please contact your distributor if you have any
questions. This manual will provide you the necessary information
for installation, operation, troubleshooting and repair of the HBU
braking unit.
Technical Specifications
Peak current: 50
Continuous current (A): 15
Braking Activation Voltage: 380 ±10 VDC (not selectable)
Maximum hysteresis: ~10 VDC
Multiple units: Maximum: 10 HBUs parallel connected
DC Bus Voltage Range: 230-380V
Moore News
NONFERROUS INDUSTRY
Non-ferrous Industry Capability
The sintering method and the Bayer process are currently the main
methods for industrial production of alumina.
Most of the alumina produced is produced by Bayer process.
The Bayer-sintering hybrid method was first created, which greatly
improved the total recovery of alumina. With the continuous
improvement of production technology, some new production methods
such as lime Bayer method and beneficiation Bayer method are
continuously applied to production.
The integrated process control system is a distributed control
system.
The system consists of eight process control subsystems (workshop)
for raw material grinding, lime digestion, dissolution,
sedimentation, seed filtration, evaporation, product filtration,
and roasting. Each workshop has an engineering station EWS and 2-3
operator stations OPS.
The data collection, real-time monitoring, data processing and
other information transmission of the internal process parameters
of the workshop are realized by the EtherNet/IP control network.The
main production operations of the entire alumina plant are
completed by these eight subsystems, each controlled by a
ControlLogix controller.
More Products
LAUER | PCS812 S7 MPI | METSO | IOP303 |
LAUER | PCS095.P | METSO | IOP345 |
LENZE | CS1002-01-00 | METSO | IOP302 |
LENZE | E82EV402K4C | MITSUBISHI | FCU6-HR377 |
LENZE | EMF2111IB | MITSUBISHI | MR-J2S-60CP |
Mitsubishi | FX2N-4AD | MODICON | AS-BADU-206 |
Mitsubishi | FX2N-2DA | MODICON | MA-0186-100 |
Mitsubishi | FX1N-40MR | MODICON | AS-P810-000 |
Mitsubishi | FX3U-32MT/ES-A | MODICON | TSXDSY32T2K |
Mitsubishi | NSSA-01-DWC | MODICON | TSXDEY64D2K |