Home Companies Wuhan Unique Mechanical And Electrical Equipment Co.,LTD.

Class 1 25mm 3core Armoured Power Cable PVC RVFV Double Steel Aluminum

Wuhan Unique Mechanical And Electrical Equipment Co.,LTD.
Active Member

Contact Us

[China] country

Address: Room B813,No.61, Yejin Avenue, Qingshan District,Wuhan City, Hubei Province, China

Contact name:

Inquir Now

Wuhan Unique Mechanical And Electrical Equipment Co.,LTD.

Class 1 25mm 3core Armoured Power Cable PVC RVFV Double Steel Aluminum

Country/Region china
City & Province wuhan hubei
Categories Control Cables
InquireNow

Product Details

Type RVFV VVFV and RVFV-K VVFV-K Double Steel Tape or Aluminum Tape Armored

 

APPLICATION

These cables are especially suitable for fixed installations that may be subject to mechanical aggression. They are highly recommended for use in installations in warehouses, production plants and agricultural facilities where the presence of rodents could imply a threat to cable integrity. At the same time, its use is recommended for street lighting installations. In some cases, these cables are used in those places where there is a potential explosion hazard such as petrol stations or flammable product warehouses.

 

 

CABLE STANDARDS

UNE 21123-2, IEC 60502, EN 60332-1, IEC 60332-1

 

Cable Construction

- Rigid electrolytic annealed copper conductor

- Class 1 (up to 4 mm2 ) or 2 (from 6 mm2 upwards) in accordance with IEC 60228

- Class 5 for (RVFV-K/VVFV-K) in accordance with IEC 60228

- XLPE insulation (RVFV/RVFV-K) or PVC insulation (VVFV/ VVFV-K) according to IEC 60502

- up to 5 conductors: by colors (RVFV/RVFV-K)

- 6 or more conductors: black numbered + green/yellow. (VVFV/VVFV-K)

- Extruded continuous PVC bedding type ST1/ST2 of standard IEC 60502.

- Double steel or aluminum tape armour

- Flexible PVC compound outer sheath type ST1/ST2 of standard IEC 60502

 

Technical Characteristics:

- Working voltage: 600/1000 volts

- Test voltage: 2000 volts

- Minimum bending radius: 10 x Ø

- Working temperature: -15º C to +90º C

- Short circuit temperature: +250º C

- Flame retardant: IEC 60332.1

- Insulation resistance: 20 MΩ x km

 

 

DIMENSIONS

AWGNo. of Cores x
Nominal Cross Sectional Area
# x mm²
Nominal
Overall Diameter mm
Nominal Weight kg/kmAWGNo. of Cores x
Nominal Cross Sectional Area
# x mm²

Nominal
Overall Diameter

mm

Nominal Weight

kg/km

61×1614.43453/03×95/5041.34613
41×25164774/03×120/7046.96,023
21×3517.3582300MCM3×150/7054.77455
11×5018.5722350MCM3×185/9555.18890
2/01×7020.7962500MCM3×240/12062.511055
3/01×9522.11173164×1.513.2275
4/01×12024.61522144×2.514.4339
300MCM1×15026.51821124×415.1419
350MCM1×18528.52230104×617.3545
500MCM1×24031.723584×1019.8770
162×1.512.322764×1622.31062
142×2.512.825944×2526.51602
122×413.6311165×1.514.4320
102×615.8411145×2.515.3390
82×1017.8552125×417.2509
62×1619.6726105×618.8640
163×1.512.825285×1021.3909
143×2.513.329365×1625.21304
123×414.5367166×1.515.8394
103×616.3468167×1.515.8412
83×1018.36411610×1.517.8521
63×1620.48701612×1.519.2603
63×16/1021.59961616×1.520.8714
43×25/1625.114681619×1.521.8792
23×35/1627.918541624×1.523.3914
13×50/2529.621011627×1.525.41015

Hot Products

NA2XRY Armoured Electrical Cable XLPE Insulation Steel Wire Armored Cable APPLICATION Can be used in ...
Type 6942X Armoured Electrical Cable Steel Wire Armoured SWA Cable APPLICATION Designed for use in ...
0.6/1Kv CU/XLPE/SWA/HDPE Armoured Electrical Cable Acc. To BS 5467 APPLICATION Low voltage SWA mains ...
Type RVFV VVFV and RVFV-K VVFV-K Double Steel Tape or Aluminum Tape Armored APPLICATION These cables ...
BS5467 Single Core Armored Electric Cable 0.6 / 1KV Aluminum Wire Armored Cable APPLICATION Single ...
BS 6622 Standard Armoured Electrical Cable XLPE MDPE 6.35/11 (12)kV Cable APPLICATION Power cables ...