N2XSY Medium Voltage Cable Out Door Direct Buried Power Distribution Cable

 

APPLICATION

Medium voltage power cable for static application in ground, within and outside facilities, outdoor, in cable canals, in water, in conditions where cables are not exposed to heavier mechanical stress and tensile strain. Due to its very low factor of dielectric loss, which remains constant over its entire operating lifetime, and owing to excellent insulation property of XLPE-material, firmly longitudinally spliced with inner and external screen of semi-conductive material (extruded in one process), the cable has a high operating reliability. Used in transformer stations, switching blocks, in electric power plants and industrial plants. To avoid the effects of external impact, the adhering semi-conductive layer extruded between conductor and insulation, along with concentric copper conductor, secures restriction of electric field and resistance to partial discharges.

 

The good installation properties of this cable make installation easy, even on difficult routes. According to VDE 0276-603 cables must be protected from sunlight.

 

CONSTRUCTION

stranded copper conductor

- conductor screeen of semiconducting compound

- insulation of cross-linked polyethylen (XLPE)

- screen of semiconducting compound plus copper wires and copper tape

- separation tape

- PVC sheath

 

International : IEC 60502-2
National : DIN VDE 0276 part 620

 
Conductor material: bare copper

Conductor class: class 2 = stranded

Insulation: XLPE DIX8

Sheathing material: PVC DMV6

Colour outer sheath: red

Flame-retardant: VDE 0482-332-1-2/IEC 60332-1-2

Maximum permitted conductor temperature: 90 °C

Permitted outer cable temperature, fixed: 70 °C

Permitted outer cable temperature, in motion/ during installation: -5 - +70 °C

Bending radius, fixed installation: 15 x DA

Partial discharge: 2 pC

 

 N2XSY 6/10 kVN2XSY 12/20 kVN2XSY 18/30 kV
Nominal voltage Uo:6 kV12 kV18 kV
Nominal voltage U:10 kV20 kV30 kV
Maximum permitted operating voltage in threephase systems:12kV24kV36kV
Test voltage:24 kV42 kV63 kV

 
DIMENSIONS

 

Number of cores x conductor cross-sectionConstructionConductor diameterInsulation thicknessExternal diameterConductor resistance at 20 °CShort circuit current 1sCu weightCable weight
  max.nominalmin.max.max.nominal prib.
N x mm² mmmmmmmmΩ/kmAkg/kmkg/km
6/10 kV
1 x 35/16RM07,53,423280,5245,00518892
1 x 50/16RM08,63,424290,3877,156621027
1 x 70/16RM10,23,426310,26810,08541254
1 x 95/16RM12,03,427320,19313,610941525
1 x 120/16RM13,53,429340,15317,213341773
1 x 150/16RM15,03,430350,12421,416222050
1 x 150/25RM15,03,430350,12421,417232135
1 x 185/16RM16,83,432370,099126,519582450
1 x 185/25RM16,83,432370,099126,520592482
1 x 240/16RM19,23,434390,075434,324863000
1 x 240/25RM19,23,434390,075434,325873045
1 x 300/25RM21,63,436410,060142,931633646
1 x 400/35RM24,63,440450,047057,242344557
1 x 500/35RM27,63,443480,036671,551945585
1 x 630/35RM31,53,448520,028390,163957090
12/20 kV
1 x 35/16RM7,55,527320,5245,005181067
1 x 50/16RM8,65,528330,3877,156621208
1 x 70/16RM10,25,530350,26810,08541446
1 x 95/16RM12,05,531360,19313,610941726
1 x 120/16RM13,55,533380,15317,213341983
1 x 150/16RM15,05,534390,12421,416222300
1 x 150/25RM15,05,534390,12421,417232353
1 x 185/16RM16,85,536410,099126,519582650
1 x 185/25RM16,85,536410,099126,520592712
1 x 240/16RM19,25,539440,075434,324863250
1 x 240/25RM19,25,539440,075434,325873290
1 x 300/25RM21,65,541460,060142,931633889
1 x 400/35RM24,65,544490,047057,242344831
1 x 500/35RM27,65,547520,036671,551946050
1 x 630/35RM31,55,551550,028390,163957340
18/30 kV
1 x 50/16RM8,68,033380,3877,156621455
1 x 70/16RM10,28,035400,26810,08541706
1 x 95/16RM12,08,036410,19313,610942001
1 x 120/16RM13,58,038430,15317,213342270
1 x 150/25RM15,08,039440,12421,417232650
1 x 185/25RM16,88,041460,099126,520593022
1 x 240/25RM19,28,043480,075434,325873618
1 x 300/25RM21,68,046510,060142,931634350
1 x 400/35RM24,68,049540,047057,242345350
1 x 500/35RM27,68,052570,036671,551946450
1 x 630/35RM31,58,057620,028390,163957800


Hot Products

BS6622 Standard 19/33(36)kv Medium Voltage Cable CU/XLPE/SWA/PVC Cable APPLICATION Power cables for ...
N2XS2Y XLPE PE Medium Voltage Cable 6/10(12) KV Single Core Power Cable APPLICATION Medium voltage ...
N2XS2Y 18/30(36) KV Medium Voltage Cable Single Core CU/XLPE/CWA/PE CONSTRUCTION Stranded copper or ...
N2XS(FL)2Y Medium Voltage Cable Longitudinally and Radially Water-proof Cable APPLICATION For ...
N2XSY Medium Voltage Cable Out Door Direct Buried Power Distribution Cable APPLICATION Medium ...
NA2XS2Y Aluminium Conductor Medium Voltage Cable for Distribution Networks APPLICATION For ...