318-B LSZH / H05Z1Z1-F Flexible Cable BS EN 50525-3-11 Class 5 LSZH For Public Areas

 

APPLICATION
Used as an indoor general wiring cable primarily for installations
in public areas. Examples include use on pendant lighting drops
or as a general supply lead within hospital or airport projects.
For installation where fire, smoke emission and toxic fumes
create a potential risk to life and equipment.

 

CABLE STANDARDS
BS EN 50525-3-11 (HD21.14), BS EN/IEC 60332-1-2

 

 

DIMENSIONS

UNI-CABLES
PART NO.
NO. OF CORESNOMINAL CROSS SECTIONAL AREA
mm²
NOMINAL THICKNESS OF INSULATION
mm
NOMINAL OVERALL DIAMETER
mm
NOMINAL WEIGHT
kg/km
UNI318B02007520.750.66.357
UNI318B02010210.66.665
UNI318B0201521.50.77.484
UNI318B0202522.50.89130
UNI318B02040240.810.4180
UNI318B03007530.750.66.768
UNI318B03010310.6778
UNI318B0301531.50.78107
UNI318B0302532.50.89.9163
UNI318B03040340.811.1212
UNI318B04007540.750.67.383
UNI318B04010410.67.9100
UNI318B0401541.50.79134
UNI318B0402542.50.810.8201
UNI318B04040440.812.2290
UNI318B05007550.750.68.1103
UNI318B05010510.68.3130
UNI318B0501551.50.710.4170
UNI318B0502552.50.812.1255
UNI318B05040540.815360

 

 

COLOUR CODE

COLOURWhiteBlack
CODEWHBK

 

 

CONDUCTORS
Class 5 Flexible Copper Conductors for Single Core and Multi-Core Cables

NOMINAL CROSS SECTIONAL AREA
mm²
MAXIMUM DIAMETER OF WIRES IN CONDUCTOR
mm
MAXIMUM RESISTANCE OF CONDUCTOR AT 20°C
  Plain Wires
ohms/km
0.750.2126
10.2119.5
1.50.2613.3
2.50.267.98
40.314.95

 The above table is in accordance with BS EN 60228 (previously BS 6360)

 

 

ELECTRICAL CHARACTERISTICS
Current Carrying Capacity and Mass Supportable

NOMINAL CROSS
SECTIONAL AREA
mm2
CURRENT CARRYING CAPACITYMAXIMUM MASS SUPPORTABLE BY
TWIN FLEXIBLE CORD
Single-Phase AC
Amps
Three-Phase AC
Amps
kg
0.75663
110105
1.516165
2.525205
432255

 

 

Voltage Drop

NOMINAL CROSS SECTIONAL AREA
mm²
DC OR SINGLE-PHASE AC
mV/A/m
THREE-PHASE AC
mV/A/m
0.756254
14640
1.53227
2.51916
41210

 Conductor operating temperature: 60ºC*

Hot Products

RV-K XLPE Insulated Low Voltage Indoors and Out Doors Power Distribution Cable APPLICATION RV-K is a ...
Type CVV JIS Standard PVC Insulated Cable for Supervisory Electrical Equipment APPLICATION CVV ...
NAYY-J / -O Low Voltage Cable Aluminum Conductor PVC Insulated Power Cable APPLICATION Distribution ...
IEC 60502-1 Standard Two Cores 0.6/1kV PVC Insulated PVC Sheath Cable APPLICATION IEC60502-1 cables ...
318-B LSZH / H05Z1Z1-F Flexible Cable BS EN 50525-3-11 Class 5 LSZH For Public Areas APPLICATION ...
NYFGY Low Voltage Cable Copper Cables With Galvanized Flat Steel Wire Armouring APPLICATION ...