Home Companies Shenzhen Wensidun Technology Co., Ltd.

Green Spring Tylosin Food Safety Anti Rapid Test Kit Rtk Antibody 96Tests/Kit For Fresh Milk Powder

Shenzhen Wensidun Technology Co., Ltd.
Active Member

Contact Us

Address: Vanke Tianyu Garden,B2-1010, Unit B, Building 9 Longcheng Street Longgang District Shenzhen, China

Contact name:Zhang

Inquir Now

Shenzhen Wensidun Technology Co., Ltd.

Green Spring Tylosin Food Safety Anti Rapid Test Kit Rtk Antibody 96Tests/Kit For Fresh Milk Powder

City & Province shenzhen
Categories Dyestuff Intermediates
InquireNow

Product Details

Tylosin Food Safety Rapid Test Kit 96Tests/Kit for Fresh Milk Powder

 

1. Specifications

8 strips/bottle, 12 bottles/kit

 

2. Tylosin Food Safety Rapid Test Kit Brief

 

The Tylosin rapid test strip is used for testing Tylosin residue in milk(including pure milk and fresh milk) and goat milk qualitatively. The whole test only need 6min, east to operate with high sensitivity.

 

3. Detection limit: 3~5ug/kg (ppb)

 

4. Tylosin Food Safety Rapid Test Kit Contents

 

1Tylosin test strip8strip/bottle
2Red powder micro-well8 micro-well/bottle
3Instruction1 piece

 

5. Principle

 

The Tylosin rapid test strip is based on competitive inhibition immuno-chromatographic principle. In the flow process, Tylosin in the sample combined with Tylosin specific colloidal gold-labeled monoclonal antibody, Inhibit the combination between antibody and Tylosin-BSA conjugate on Test line of NC membrane, lead to the color change of Test line. When the sample has no Tylosin residue or concentration lower than detection limit, T line is darker then C line; when the concentration is equal to or higher than detection limit, T line is lighter than C line or T line has no color or T line has same color with C line. No matter whether there is Tylosin residue in sample, C line will appear, it means the test is valid.

 

6. Operation procedures

 

6.1 Read the instruction carefully before use. Return test strips and sample into room temperature.

6.2 Take bottles needed from the kit package, take out required microwells, making proper marks, Please use it in 1 hour. Seal the cap of the bottles, avoid moisture.

6.3 Use Micro-pipette to take 200ul of the samples into the microwells, then repeatedly absorb for 5 times, mix the sample with the reagent in the microwells completely until no solid judged by eyes (this is a very important step).

6.4 Incubate at 40±2℃for 3 min. Then insert the strip into micro-well, put the end with MAX down into the liquid.

6.5 Insert the strip into the liquid for 3min, then read the result.

 

7. Test Result Interpretation

 

Color depth comparison of T line and C lineResult judgmentResult analysis
T line >C lineNegativeTylosin residue is lower than detection limit in sample
T line =C lineWeak positiveTylosin residue is equal to detection limit in sample
T line <C line or T line is invisiblePositiveTylosin residue is higher than detection limit in sample
C line is invisibleInvalidThe test strip is invalid, test again

 

8. Precautions

 

1) The test strip is used for once at room temperature, do not use test strip out of date.

2) Cover the bottle immediately after taking out the reagent. If can’t use 8 micro-wells for one time, cover the micro-wells immediately and put back to the bottle, store in seal.

3) Do not touch the white membrane surface in the middle of test strip, avoid sunlight and fan blowing directly.

4) Milk samples should be fully liquid without any agglomeration, sour and precipitation

5) Use the test strips testing again for positive results.

6) Please contact the supplier for any questions.

7) The result is for reference. To confirm, please refer national standard method.

 

9. Specificity

 

This product has no cross-reaction with Quinolones, Sulfonamides and Tetracyclines etc.

 

10. Storage and expiry date

 

Storage: Store at 2-8 ℃ in dark, sealed, dry place, no frozen.

Expiry date: 12 months; date of production is on box.

 

 

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In the event of the epidemic and other external factors, there may be delays in shipping)

 

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.

 

Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.

 

Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.

 

Q5: What is the payment method?
A5: We receive payment by T/T.

 

Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.

Hot Products

Clenbuterol Salbutamol Rapid Test Card for Urine 30 Tests/Kit 1. Brief This product is used for ...
Nitrofuran AOZ Rapid Test Strip for Tissue 96 Tests/Kit 0.5 ppb 1. Specifications 96 strips/kit 2. ...
Clenbuterol Rapid Test Card for Tissue Urine 20 Tests/Kit 3 ppb 1. Introduction This product is used ...
Salbutamol Rapid Test Card for Tissue Urine 20 Tests/Kit 3 ~ 5 ppb 1. Introduction This product is ...
Tylosin Food Safety Rapid Test Kit 96Tests/Kit for Fresh Milk Powder 1. Specifications 8 strips...
Chloramphenicol Rapid Test Strip for Tissue 96 Tests/Kit 0.1 ppb 1. Specifications: 8 dipsticks...