Home Companies Shenzhen Wensidun Technology Co., Ltd.

Nitrofuran AOZ Elisa Diagnostic Kits Rapid Test Kit For Fish 96 Wells/Kit Sensitivity 0.01

Shenzhen Wensidun Technology Co., Ltd.
Active Member

Contact Us

Address: Vanke Tianyu Garden,B2-1010, Unit B, Building 9 Longcheng Street Longgang District Shenzhen, China

Contact name:Zhang

Inquir Now

Shenzhen Wensidun Technology Co., Ltd.

Nitrofuran AOZ Elisa Diagnostic Kits Rapid Test Kit For Fish 96 Wells/Kit Sensitivity 0.01

City & Province shenzhen
InquireNow

Product Details

Nitrofuran AOZ Diagnostic ELISA Kit for Fish 96 Wells/Kit Sensitivity 0.01

 

 

1. Nitrofuran AOZ Diagnostic ELISA Kit Principle

 

This test kit is based on the competitive enzyme immunoassay for the detection of AOZ in the sample. The coupling antigens are pre-coated on the micro-well stripes. The AOZ in the sample and the coupling antigens pre-coated on the micro-well stripes compete for the anti-AOZ antibodies. After the addition of the enzyme conjugate, the TMB substrate is added for coloration. The optical density (OD) value of the sample has a negative correlation with the AOZ in it. This value is compared to the standard curve and the AOZ concentration is subsequently obtained.

 

2. Technical specifications


Sensitivity: 0.01ppb
Incubation Temperature: 25℃
Incubation Time: 30min~15min
Detection limit
Tissue, egg, honey: 0.05ppb


Cross-reaction rate: AOZ 100%, AMOZ <0.1%, AHD <0.1%, SEM <0.1%


Recovery rate: 
Tissue, egg 95±25%
Honey 85±23%

 

3. Nitrofuran AOZ Diagnostic ELISA Kit Components

 

1Micro-well strips

12 strips with 8 removable

wells each

26× standard solution (1mL each)0ppb0.01ppb
0.03ppb0.09ppb
0.27ppb0.81ppb
3Enzyme conjugate7mlred cap
4Antibody working solution7mlblue cap
5Substrate A7mlwhite cap
6SubstrateB7mlblack cap
7Stop solution7mlyellow cap
820× concentrated washing buffer40mlwhite cap
92× concentrated redissolving solution50mltransparent cap
102-Nitrobenzaldehyde(C7H5NO3)10mlblack cap

 

4. ELISA procedure


4.1 Description
1) Bring all reagents and microwell strips to room temperature (20-25°C) before use;
2) Return all reagents to 2-8°C immediately after use;
3) The reproducibility of ELISA assays largely depends on the consistency of plate washing. Correct plate washing is the key to ELISA procedures;
4) During the constant temperature incubation, all samples and reagents must be protected from light, and each microplate is sealed with a cover film.


4.2 Operating Procedure
1) Put the kit at room temperature (20-25°C) for at least 30 minutes, note that each reagent must be shaken and mixed well before use, and put the required microwell strips into the plate frame. Unused microplates should be resealed and stored at 2-8°C rather than frozen.
2) Solution preparation: 40 mL of 20× concentrated wash buffer diluted 1:19 with deionized water (1 part 20× concentrated wash buffer + 19 parts deionized water). Or prepare as needed. .
3) Numbering: Number the microwells according to the samples and standard solutions; each sample and standard solution should be made in duplicate, and their positions should be recorded.
4) Add 50 µL of sample or standard solution to separate double wells; add 50 µL of enzyme conjugate and 50 µL of antibody working solution to each well, and shake the plate by hand to mix gently. Seal the microplate with a cover film and incubate at 25°C for 30 min.
5) Pour out the liquid in the microwell, pat dry with absorbent paper, add 250 µL/well of washing buffer to wash the microwell plate for 15-30 s, then remove and pat dry with absorbent paper, repeat 4-5 times. (If there are air bubbles after tapping, use a clean tip to cut them off).
6) Color development: Add 50 µL of Substrate A and 50 µL of Substrate B to each well. Shake the plate by hand to mix gently and incubate at 25°C for 15 min in the dark for color development.
7) Detection: Add 50 µL of stop solution to each well. Shake the plate by hand to mix gently. Set the wavelength of the microplate reader to 450 nm to determine the OD value of each well. (It is recommended to read the OD value of dual wavelength 450/630nm within 5 minutes).

 

 

5. Storage and validity period


Storage: 2-8 ℃ storage, do not freeze.
Expiry date: 12 months; production date is on the box.
Note: If the microplate vacuum packaging leaks, it can still be used without affecting the test results, so you can use it with confidence.

 

 

 

 

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In case of external factors such as the epidemic, the delivery may be delayed)

 

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces, which is convenient for customized products.

 

Q3: How is your factory doing in terms of quality control?
A3: We have nationally certified ISO9001 and ISO13485. Our production process conforms to standard procedures to ensure optimum product quality.

 

Q4: How to provide after-sales service?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance via video, telephone, etc.

 

Q5: What is the payment method?
A5: We receive payment by T/T.

 

Q6: How to ship?
A6: Choose the best shipping method for you by getting quotes from our many cooperative carriers, and also ship according to your requirements.

Hot Products

Olaquindox ELISA Test Kit for Chicken Pork Duck 96 Wells/Kit Sensitivity 0.2 ppb 1. Principle This ...
Nitrofuran AMOZ Diagnostic ELISA Kit for Milk Sensitivity 0.03ppb 96Wells/Kit 1. Diagnostic ELISA ...
Nitrofuran AHD Diagnostic ELISA Kit for Aquatic Products 96Wells/Kit 1. Nitrofuran AHD Diagnostic ...
Nitrofuran SEM Diagnostic ELISA Kit for Shrimp 96 Wells/Kit Sensitivity 0.02 1. Nitrofuran SEM ...
Nitrofuran AOZ Diagnostic ELISA Kit for Fish 96 Wells/Kit Sensitivity 0.01 1. Nitrofuran AOZ ...
Melamine Diagnostic ELISA Kit for Fresh Milk 96 Wells/Kit Sensitivity 0.5 1. Melamine Diagnostic ...