Oxytetracyline Rapid Test Strip for Milk 96 Tests/Kit Detection limit 5 ~ 10 ppb

 

1. Specifications:

 

8 pcs/bottle, 12 bottles/box


2. Introduction


This product is used for the qualitative detection of oxytetracycline in milk samples (pure milk and fresh milk) and goat milk samples. The entire testing process takes only 6 minutes, with simple operation and high sensitivity.


3. Detection limit:

 

5-10ppb (ug/kg)


4. Content

 

Oxytetracyline test dipsticks8 dipsticks/bottle
Red powder micro-wells8 micro-wells/bottle
Manual1 piece
Desiccant2 pieces/bottle

 

5. Principles


Oxytetracycline rapid test strips are based on the principle of competitive inhibition immunochromatography. During the flow process, the oxytetracycline in the sample binds to the oxytetracycline-specific colloidal gold-labeled monoclonal antibody, which inhibits the binding of the antibody to the oxytetracycline-BSA conjugate on the detection line of the NC membrane, causing the detection line to change. color. When the sample has no oxytetracycline residue or the concentration is below the detection limit, the T line is deeper than the C line. When the concentration is at or above the detection limit, the T line is significantly lighter than the C line, or the T line has no color, or the T line is the same color as the C line. The C line appears whether or not oxytetracycline remains in the sample, indicating that the test is valid.


6. Operating procedures


6.1 Please read the manual carefully before use. Return the test strip and sample to room temperature.
6.2 Take out the required bottle from the kit, take out the required microwell and test paper, and make a mark. Please use these test strips within 1 hour. Seal lid to avoid moisture.
6.3 Take 200ul of the sample to be tested in the microwell, and suck it for 5 times to make the sample and the reagent in the microwell fully mixed until the naked eye judges that there is no solid (this is very important step).
6.4 (40±2℃) incubate for 3min, then insert the test paper into the microwell, and the “MAX” end is completely immersed in the mixed solution.
6.5 Insert the test strip into the microwell for 3 minutes to read the result, other time is invalid.


7. Interpretation of test results

 

Color depth comparison of T line and C lineResult judgmentResult analysis
T line > C lineNegativeOxytetracyline residue is lower than detection limit in sample
T line = C lineWeak positiveOxytetracyline residue is equal to detection limit in sample
T line < C line or T line is invisiblePositiveOxytetracyline residue is higher than detection limit in sample
C line is invisibleInvalidThe test dipstick is invalid, test again

 

 

8. Precautions


1) Test strips can only be used once at room temperature, do not use expired test strips.
2) Please seal the bottle after taking out the required test strips. If you cannot use all 8 microwells at once, return the remaining cups to the bottle and seal.
3) Do not touch the white film surface in the middle of the test card, avoid direct sunlight and direct blowing of fans.
4) The milk sample to be tested should be completely liquid without any clumping and sedimentation.
5) Use the test strips again for a positive result.

 

9. Specificity


Tests 500ppb sulfonamides, quinolones, chloramphenicol, melamine and other drugs. All results were negative.


10. Storage and expiration date


Storage: 2-8 ℃ dark, sealed, dry place, not frozen.
Expiration date: 12 months; production date is on the box.

 

 

 

 


 

Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7 working days after receiving the payment. (In case of external factors such as the epidemic, the delivery may be delayed)

 

Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more than 100,000 pieces to facilitate customized products.


Q3: How is your factory doing in terms of quality control?
A3: We have ISO9001 and ISO13485 certified by the state. Our production process is in accordance with the standard process, which can ensure that the quality of the products is optimal.


Q4: How is after-sales service provided?
A4: We provide professional online technical after-sales service. We can provide you with one-on-one guidance in the form of video, phone calls, etc.


Q5: What is the payment method?
A5: We receive payment by T/T.


Q6: How to ship?
A6: By obtaining quotations from our many cooperative carriers, choose the best way to ship for you, or you can ship according to your requirements.

Hot Products

Brucellosis Antibody ELISA Kit for Bovine Goat Sheep Pig and Dog 96Wells/Kit 1. Introduction The ...
Melamine Rapid Test Strip for Fresh Milk Powder 96Tests/Kit ISO9001 1. Specifications: 8 dipsticks...
Melamine ELISA Test Kit for Detection Milk 96Wells/Kit ISO9001 1. Principle This test kit is based ...
Tilmicosin Rapid Test Strip for Milk 96 Tests/Kit Detection limit 5 ~ 8 ppb 1. Milk Test Kit ...
Oxytetracyline Rapid Test Strip for Milk 96 Tests/Kit Detection limit 5 ~ 10 ppb 1. Specifications: ...
Neomycin Rapid Test Strip for Milk 96 Tests/Kit Detection limit 5 ~ 10 ppb 1. Specifications: 8 pcs...