Shenzhen Wensidun Technology Co., Ltd. |
|
Tetracyclines Gentamicin and Quinolones Combo Rapid Test Strip 96 Tests/Kit
1. Specifications
8 strips/bottle, 12 bottles/kit
2. Brief
The Tetracyclines, Gentamicin and Quinolones combo rapid test strip
is based on Colloidal gold immunochromatography, used for testing
Tetracyclines, Gentamicin and Quinolones residue in milk(including
pure milk and fresh milk) and goat milk qualitatively. The whole
test only need 10min, east to operate with high sensitivity.
3. Detection limit:
Quinolones | Detection limit (ppb) | Tetracyclines | Detection limit (ppb) | Gentamicin | Detection limit (ppb) |
Enrofloxacin | 2-3 | Tetracycline | 10-15 | Gentamicin | 3-5 |
Ciprofloxacin | 2-3 | Oxytetracycline | 10-15 | ||
Norfloxacin | 2-3 | Chlortetracycline | 10-15 | ||
Pefloxaein | 2-3 | Doxycycline | 15-20 | ||
Sarafloxacin | 2-3 | ||||
Ofloxacin | 2-3 | ||||
Danofloxacin | 2-4 | ||||
Flumequine | 2-3 | ||||
Enoxacin | 3-5 | ||||
Lomefloxacin | 2-3 | ||||
Marbofloxacin | 3-5 | ||||
Nadifloxacin | 3-5 | ||||
Bifloxacin | 3-5 | ||||
Cinoxacin | 5-8 | ||||
Oxolinic Acid | 2-3 |
4. Contents
1 | Test strip | 8strip/bottle |
2 | Red powder micro-well | 8 micro-well/bottle |
3 | Desiccant | 2piece/bottle |
4 | Instruction | 1 piece |
5. Principle
The Tetracyclines, Gentamicin and Quinolones combo rapid test strip
is based on competitive inhibition immuno-chromatographic
principle. In the flow process, antibiotics in the sample combined
with antibiotics specific colloidal gold-labeled monoclonal
antibody, Inhibit the combination between antibody and
antibiotics-BSA conjugate on Test line of NC membrane, lead to the
color change of Test line. When the concentration is equal to or
higher than detection limit, T line is lighter than C line or T
line has no color or T line has same color with C line.When the
sample has no antibiotics residue or concentration lower than
detection limit, T line is darker then C line; No matter whether
there is antibiotics residue in sample, C line will appear, it
means the test is valid.
6. Operation procedures
6.1 Read the instruction carefully before use. Return test strips
and sample into room temperature.
6.2 Take bottles needed from the kit package, take out required
microwells, making proper marks, Please use it in 1 hour. Seal the
cap of the bottles, avoid moisture.
6.3 Use Micro-pipette to take 200ul of the samples into the
microwells, then repeatedly absorb for 5~10 times, mix the sample
with the reagent in the microwells completely until no solid judged
by eyes (this is a very important step).
6.4 Incubate at (40±2℃) for first step, timing for 5min.
6.5 Then insert the strip into micro-well, put the end with MAX
down into the liquid, Incubate at (40±2℃) for second step, timing
for 5min.
6.6 Take out the strip and read the result as the picture, it is
invalid to read result in other times.
7. Test Result Interpretation
Color depth comparison of T line and C line | Result judgment | Result analysis |
T line > C line | Negative | Antibioticsresidue is lower than detection limit in sample |
T line = C line | Weak positive | Antibiotics residue is equal to detection limit in sample |
T line < C line or T line is invisible | Positive | Antibiotics residue is higher than detection limit in sample |
C line is invisible | Invalid | The test strip is invalid, test again |
8. Precautions
1) This product is suitable for pure milk and goat milk, fresh
milk.
2) The test strip is used for once at room temperature, do not use
test strip out of date.
3) Cover the bottle immediately after taking out the reagent. If
can’t use 8 micro-wells for one time, cover the micro-wells
immediately and put back to the bottle, store in seal.
4) Do not touch the white membrane surface in the middle of test
strip, avoid sunlight and fan blowing directly.
5) Store the milk sample in cold, no more than 3 days.
6) Milk samples should be fully liquid without any agglomeration,
sour and precipitation. Mix and stir sample evenly before testing.
7) For high-fat sample,Chromatography speed is slow, recommend to
extend second step for another 1 min.
8) Use the test strips testing again for positive results.
9. Specificity
This product has no cross-reaction with Chloramphenicol,
Sulfonamides and Melamine etc.
10. Storage and expiry date
Storage: Store at 2-8 ℃ in dark, sealed, dry place, no frozen.
Expiry date: 12 months; date of production is on box.
Q1: When will it be shipped?
A1: We will ship the goods for you as soon as possible within 7
working days after receiving the payment. (In case of external
factors such as the epidemic, the delivery may be delayed)
Q2: Does it support OEM/ODM?
A2: It can be supported, but the specific quantity needs to be more
than 100,000 pieces, which is convenient for customized products.
Q3: How is your factory doing in terms of quality control?
A3: We have nationally certified ISO9001 and ISO13485. Our
production process conforms to standard procedures to ensure
optimum product quality.
Q4: How to provide after-sales service?
A4: We provide professional online technical after-sales service.
We can provide you with one-on-one guidance via video, telephone,
etc.
Q5: What is the payment method?
A5: We receive payment by T/T.
Q6: How to ship?
A6: Choose the best shipping method for you by getting quotes from
our many cooperative carriers, and also ship according to your
requirements.