Ce Iso Approved Urine Adulteration Test Strip With Drug Test Rapid Test

 

Products Description

 

Urine Adulteration Test Strip


1.Quick dip-and-read Test
2.Accurate results in 30 sec to 2 min
3.Ready-to-use and disposible

 

Intended Use:


The Urinalysis Reagent Strips (Urine) are firm plastic strips onto which several separate reagent areas are affixed. The test is for the qualitative and semi-quantitative detection of one or more of the following analytes in urine: Ascorbic acid, Glucose, Bilirubin, Ketone (Acetoacetic acid), Specific Gravity, Blood, pH, Protein, Urobilinogen, Nitrite and Leukocytes.

 

Test parametersURS-10T,URS-11,URS-12MA
wave length558nm, 635nm, 720nm
Test speedUp to 120 tests/hour at Continuous
Memory Size1000 test results
optional10, 11 OR 12 parameters
PrintThermal printer inside, with outer stylus printer interface
Host-communicationPC connected with RS232
LanguageEnglish
Environment Condition0-40°C,RH< 85%
Power SupplyAC 220V(±15%),50-60Hz
Power≤60W
Carton Dimensions(L/W/H)580×300×300mm

 

 

Reagent

Read

Time

CompositionDescription
Ascorbic Acid(ASC)30 seconds

2,6-dichlorophenolindophenol;

buffer and non-reactive ingredientss

Detects ascorbic acid as low as 5-10 mg/dL (0.28-0.56 mmol/L).

Glucose

(GLU)

30

seconds

glucose oxidase; peroxidase;

potassium iodide; buffer;

non-reactive ingredients

Detects glucose as low as

50-100 mg/dL (2.5-5 mmol/L).

Bilirubin

(BIL)

30

seconds

2, 4-dichloroaniline diazonium

salt; buffer and non-reactive

ingredients

Detects bilirubin as low as

0.4- 1.0 mg/dL(6.8-17 μmol/L)

Ketone

(KET)

40

seconds

sodium nitroprusside; bufferDetects acetoacetic acid as low as 2.5-5 mg/dL (0.25-0.5 mmol/L).

Specific

Gravity

(SG)

45

seconds

bromthymol blue indicator;

buffer and non-reactive

ingredients; poly (methyl vinyl

ether/maleic anhydride);

sodium hydroxide

Determines urine specific gravity

between 1.000 and 1.030. Results correlate with values obtained by refractive index method within ±0.005.

Blood

(BLO)

60 seconds

3,3’,5,5’ tetramethylbenzidine

(TMB); diisopropylbenzene

dihydroperoxide; buffer and

non-reactive ingredients

Detects free hemoglobin as low as 0.018-0.060 mg/dL or 5-10 Ery/μL in urine specimens with ascorbic acid content of< 50 mg/dL.
pH

60

seconds

methyl red sodium salt;

bromthymol blue; non-reactive ingredients

Permits the quantitative

differentiation of pH values

within the range of 5- 9.

Protein

(PRO)L)

60

seconds

tetrabromophenol blue; buffer and non-reactive ingredientsyDetects albumin as low as 7.5-15 mg/dL (0.075-0.15 g/L).

Urobilinogen

(URO)

60

seconds

p-diethylaminobenzaldehyde;

buffer and non-reactive

ingredients

Detects urobilinogen as low as 0.2-1.0 mg/dL (3.5-17 μmol/L).

Nitrite

(NIT)

60

seconds

p-arsanilic acid; N-(1-naphthyl)ethylenediamine; non-reactive ingredientsLDetects sodium nitrite as low as 0.05-0.1 mg/dL in urine with a low specific gravity and less than 30 mg/dL ascorbic acid.

Leukocytes

(LEU)

120

seconds

derivatized pyrrole amino acid

ester; diazonium salt; buffer;

non-reactive ingredients

Detects leukocytes as low as 9-15 white blood cells Leu/UL in clinical urine.

 

 

Test Procedure And Result Interpretation

 

Adulteration Test Strips:


Drug adulteration test strips are used to determine if the urine sample has been intentionally manipulated, contaminated or diluted in order to pass a drug screen. A six in one test, it identifies the following: Creatinine, Glutaraldehyde, Nitrite,
Specific Gravity Oxidants( bleach, and Pyridinium Chlorochromate), pH-Testing.


Adulteration Test Strips (Specimen Validity Tests):


When a donor attempts to alter the drug test result by tampering with the urine specimen that is considered to be adulteration.
The use of adulterants can cause false negative results in drug tests by destroying the drugs present in the urine or interfering with the test itself.
There are several methods drug abusers have used to try and beat the drug test such as diluting or adding substances to the specimen, flushing their system, etc. Adulteration test strips (Specimen Validity Tests) are a cost effective way to determine if the donor has adulterated their specimen in as little as 1 minute.


Parameters on Adulteration Test Strips (SVT):


- Creatinine – Creatinine is a waste product of creatine, an amino-acid contained in muscle tissue and found in urine. A person may attempt to foil a test by drinking excessive amounts of water or diuretics such as herbal teas to “flush” the system.Creatinine and specific gravity are two ways to check for dilution and flushing. Low creatinine and specific gravity levels may indicate dilute urine. The absence of creatinine (<5 mg/dl) is indicative of a specimen not consistent with human urine.


- Specific Gravity tests for sample dilution. Values outside the normal range of 1.003 to 1.030 may be the result of specimen dilution or adulteration.
 

- Nitrite – include common commercial adulterants such as Klear or Whizzies. They work by oxidizing the major cannabinoid metabolite THC-COOH. Normal urine should contain no trace of nitrite.
 

- Glutaraldehyde – Adulterants such as UrinAid and Clear Choice contain glutaraldehyde which may cause false negative screening results by disrupting the enzyme used in some immunoassay tests. Glutaraldehyde is not normally found in urine.
 

- pH – Normal pH levels should be in the range of 4.0 to 9.0. Values outside of this range may indicate sample tampering.
 

- Oxidants/PCC – Oxidizing agents such as bleach, hydrogen peroxide and pyridinium chlorochromate (UrineLuck) are commonly used adulterants. Normal human urine should not contain oxidants or PCC.

 

Available in the following formats:


- Dip strip (packaged 25 per canister)
- Also available in some multi-drug panel and integrated cup formats.

 

 

Q1: Are you a Manufacturer?
Yes, we are manufacturer based in Hangzhou, China with 165 workers, 8000 square meter non-dust workshop, advanced autonnate machines and professional R&D team ensure the high quality, speedy delivery and large production capacity.

 

Q2: Can we put our logoltext on the products or package?
Yes, we can do OEM or even ODM. All of our products can be customized.

 

Q3: Can you provide free samples?
Yes, free samples are provided. But you need to pay the freight.

 

Q4: How long is your delivery time?
Our delivery time is usually two to three weeks after receiving the deposit. For a container order quantity, the production time is four weeks. It depends on the specific situation.

 

Q5: What is the MOQ?
Small quantity like 1000pcs is available.

 

Q6: How to make the payment?
By T/T.

Hot Products

Home or Work Drug Test Cotinine Nicotine Tobacco COT Urine Testing Kit Cotinine (COT) Rapid Test ...
Individually Wrapped 6 Panel Multi Screen Urine Drug Test Kit Pathological Analysis Equipments ...
Saliva Drug Test Dip Card Oral COC MET BZO THC OPI AMP Drug Test Saliva Test Kit Multi-drug Rapid ...
Ce Iso Approved Urine Adulteration Test Strip With Drug Test Rapid Test Products Description Urine ...
One Step Diagnostic Kit Faecal Occult Blood FOB Test Cassette 25 Tests/Kit Products Description FOB ...
Ce iso Approved Manual D-dimer Whole Blood Plasma Serum Rapid Test Device 40 Tests/Kit Specification ...