FPV+Giardia Lamblia Antigen Combo Rapid Test Cassette (Feces),Dog
Test Kits,Chromatographic Immunoassay
Product: | FPV+Giardia Lamblia Antigen Combo Rapid Test Cassette (Feces),Dog
Test Kits,Chromatographic Immunoassay |
Specimen: | Plasma/Serum |
Shelf Life: | 2 Years |
Reading Time: | 10 Minutes |
Specificity: | 95.18% |
Principle: | Chromatographic Immunoassay |
Pack: | 10 T |
Format: | Cassette |
Sensitivity: | 96.59% |
Accuracy: | 95.91% |
INTENDED USE
FPV+Giardia Lamblia Antigen Combo Rapid Test Cassette (Feces) is a combined cassette to differentially diagnose the
presence of Feline Panleucopenia Virus and Giardia lamblia antigen in cat’s feces.
PRINCIPLE
FPV+Giardia Lamblia Antigen Combo Rapid Test Cassette is based on sandwich lateral flow immunochromatographic assay.
The test device has two testing windows. Each testing window has an invisible T (test) zone and C (control) zone. When sample is applied into the sample well on the cassette, the liquid will
laterally flow on the surface of the test strip. If there is enough FPV or Giardia antigen in the sample, a visible T line will appear in the corresponding testing window. The C line should always appear after a sample is applied, indicating a valid result. By this
means, the cassette can accurately indicate the presence of FPV or Giardia antigen in the sample.
STORAGE AND STABILITY
Store as packaged in the sealed pouch either at room temperature or refrigerated (2-30 °C). The test is stable through the
expiration date printed on the sealed pouch. The test cassette must remain in the sealed pouch until use. DO NOT FREEZE. Do not use beyond the expiration date.
DIRECTIONS FOR USE
Allow the test cassette, specimen and buffer to equilibrate to room temperature (15-30 °C) prior to testing.
1. Collect feces with the swab stick from anus or from the ground. The amount of fecal swab as follows:
2. Insert the wet swab into the buffer tube provided with the kit. Swirl and shake to ensure sufficient sample extraction.
3. Place the test cassette on a clean and level surface. Hold the dropper vertically and transfer 3 drops of extracted sample
(approximately 120 μL) to the specimen well (S) of the test cassette, then start the timer. See illustration below.
4. Read the result in 10 minutes. Do not interpret results after 15 minutes.
Positive: The presence of both C line and T line, regardless of T line being strong or faint.
Negative: Only clear C line appears.
Invalid: No colored line appears in C zone, regardless of T line’s appearance.