Endress+Hauser FMU90-R11CA111AA3A Ultrasonic measurement Time-of-Flight Prosonic FMU90

 

SPECIFICATIONS:

1. Approval: R  Non-hazardous area
2. Application: 1  Level + pump control, alternating
3. Housing, Material: 1  Field mounting PC, IP66 NEMA4x
4. Operation: C  Illuminated display + keypad
5. Power Supply: A  90-253VAC
6. Level Input: 1  1x sensor FDU9x/8x
7. Switch Output: 1  1x relay, SPDT
8. Output: 1  1x 0/4-20mA HART
9.  Additional Input:  A  W/o
10. Datalog Function: A  Basic version
11. Language: 3  EN, ZH, JA, KO, TH, ID
12. Additional Option: A  Basic version
Gross weight: 0.450 Kilogram
Transmitter in housing for field or top hat rail mounting for up to 2 sensors FDU90/91/92/93/95

 

Specs at a glance

1Accuracy
+/- 2mm + 0.17% of measured distance

 

Field of application

Prosonic FMU90 separated version with field housing or top hat rail housing for control cabinet instrumentation are suited for continuous, non-contact level measurement of fluids, pastes, sludge and powdery to coarse bulk solids. Also the flow measurement in open channels and weirs is possible as the simultaneous measurement of level and flow in a storm water overflow basin with only 1 sensor. Up to 6 relays for tendency alarm, flow pulse output or backwater/sludge alarm, 1 or 2 channel version.

Level measurement of fluids and bulk materials with 1 or 2 sensors for measuring of up to 45m (148ft) and level limit detection. Pump control, rake control and as option: additional pump control function.

-Calculations: Average, difference, sum

-Application flow: Flow measurement in open channels and weirs with 1 or 2 sensors

-Flow measurement with back water or sludge detection

-Up to 3 totalizers and 3 counters

-Counting or time pulse output for control of external units

 

Benefits

  • Simple, menu-guided operation with 6-line plain text display, 15 languages selectable
  • Envelope curves on the display for quick and simple diagnosis
  • Easy operation, diagnosis and measuring point documentation with the supplied "FieldCare" operating program
  • Time-of-Flight correction via integrated or external temperature sensors
  • Linearisation (up to 32 points, freely configurable) for the most common flumes and weirs pre-programmed and selectable
  • Online calculation of the flume-/weir-flows via integrated flow curves
  • Automatic detection of the sensors FDU9x

Related Product Recommendation:

FMU90-L11CA232BA3A
FMU90-N11CA111AA1A
FMU90-R11CA111AA3A
FMU90-R11CB131AA3A
FMU90-R11CA111AA1A
FMU90-R11CA111AA2A+1
FMU90-L11CA232AA1A
FMU90-R11CA111AA2A
FMU90-R11CA111AA2A
FMU90-R41CA131AA1A
FMU90-R41CA111AA1A
FMU90-A11CA111AA1A
FMU90-R21CA131AA1A
FMU90-R21CA112AA3A
FMU90-R21CA111AA3A
FMU90-R11CA131AA1A
FMU90-J13CA111AA3A
FMU90-R11CA212AA3A
FMU90-R12CA111AA1A
FMU90-L11CA111AA2A+1

 

Frequently Asked Questions:

Q:What is the warranty of goods?

A: One-year Warranty.

Hot Products

Endress+Hauser COS61-A1F0 Dissolved oxygen sensor Oxymax COS61 SPECIFICATIONS: 1. Approval: A Non...
Endress+Hauser CPS11E-AA7BAA2 Digital pH sensor Memosens CPS11E SPECIFICATIONS: 1. Approval: AA Non...
MTL4525 SOLENOID/ALARM DRIVER The MTLx525 enables an on/off device in a hazardous area to be ...
MTL5524 SOLENOID/ALARM DRIVER The MTL5524 enables an on/off device in a hazardous area to be ...
MTL5546 MTL Instruments Isolating Driver The MTL5546 accepts a 4/20mA floating signal from a safe...