Home Companies GANDO INTERNATIONAL (HONGKONG) LIMITED

Vector Control Drives of AC Machines for Lift Control

GANDO INTERNATIONAL (HONGKONG) LIMITED
Active Member

Contact Us

Address: 701 of NO.69, xilinxili, siming, xiamen, China

Phone: 86-013-2436807

Contact name:

Inquir Now

GANDO INTERNATIONAL (HONGKONG) LIMITED

Vector Control Drives of AC Machines for Lift Control

City & Province xiamen fujian
Categories Inverters & Converters
InquireNow

Product Details

Vector Control Drives of AC Machines for Lift Control

Lift control is widely used in industries like mining, ports, building and so on. It requires the control stable and safe in any time and avoiding any out of control case.

 

Application Challenges

· Motor and Drive sizing
Conveyors requires a good deal of load and speed calculations,  combined with actual testing to ensure proper size (power) requirements.

· Smooth product motion
Acceleration/Deceleration times combined with S-Curve “smoothing” characteristics need fine-tuning to ensure the product is not damaged and/or moved out of position for staging to subsequent processes.

· Rapid deceleration or downhill speed control of conveyors cause load regeneration in drives. 
Care should be taken to ensure proper sizing of a drive’s dynamic braking package or regenerative converter,  to prevent drive overvoltage faults.

· Electronic Gearing
Follow an external encoder to synchronize conveyor with other sections of the process

· Coordinate conveyor motion with external machine axes

· Reduce application development time

 

Features of V5 series matching lift control application

 

Features

Benefits

For  lift control

  • Step torque response: It can quickly follow the equipment load change to prevent the runaway situation and ensure the safe production.    
  • Four quadrant operations: It can smoothly and quickly switch the forward and reverse motoring and generating state of the equipment.  

Torque monitoring: It can adjust, limit, display and switch the torque output, so as to monitor the operating state of the equipment.

 

 

Power range of V5 VFD

Voltage: 3 phase 380VAC (323VAC – 528VAC)

Power: 1.5kw/2HP – 400kw/535HP

 

Specification of V5 VFD

Item

Specification

Input frequency

50/60Hz

Output frequency

0-300Hz

Overload current

150% rated current 1min.,  180% 10 sec.,  200% 0.5 sec.

Control mode

sensor-less vector control,  V/F control

Starting torque

180% 0.5Hz (180% 0.25Hz)

Control precision

±0.05% ( ±0.02%)

Torque precision

±5%

Frequency setting mode

Operation panel setting, terminal UP/DN setting, host computer communication setting, analog setting AI1/AI2/AI3, terminal pulse DI setting

Efficiency

At rated power, 7.5kW and below power class ≥93%, 45kW and below power class ≥95%, 55kW and above power class ≥98%

Frequency setting signal

-10V~+10V; 0~+10V; 0~20mA; 0.2Hz~50kHz

Protection function

Power supply undervoltage, overcurrent protection, overvoltage protection, interference protection, abnormal comparison reference input, auto-tuning failure, module protection, heatsink overtemperature protection, inverter overload protection, motor overload protection, peripheral protection, abnormal current detection, output to ground short circuit, abnormal power failure during operation, abnormal input power, output phase failure, abnormal EEPROM, abnormal relay contact, temperature sampling disconnection, encoder disconnection, abnormal +10V power supply output, abnormal analog input, motor overtemperature (PTC), abnormal communication, abnormal version compatibility, abnormal copying, abnormal expansion card connection, terminal mutual exclusion detection failure, hardware overload protection

Enclosure

IP20

Cooling mode

forced air cooling

Vibration

3.5mm, 2~9Hz; 10 m/s2, 9~200Hz

Ambient temperature / Humidity

-40 Degrees~+70 Degrees / 5~95%Rh (no condensation)

 

Tips:

A variable-frequency drive (VFD) is a system for controlling the rotational speed of an alternating current (AC) electric motor by controlling the frequency of the electrical power supplied to the motor. A variable frequency drive is a specific type of adjustable-speed drive. Variable-frequency drives are also known as adjustable-frequency drives (AFD), variable-speed drives (VSD), AC drives, microdrives or inverter drives. Since the voltage is varied along with frequency, these are sometimes also called VVVF (variable voltage variable frequency) drives.
 

Hot Products

400V Variable Frequency AC VFD Drives for Decanter Centrifuge Decanter centrifuges are used to ...
Variable Frequency AC Drives Inverter with Voltage 400VAC for Mixer Mixers are used in a wide range ...
AC Variable Frequency Inverter Drives VFD for Screw Feeder 400V Screw feeders are used in various ...
Variable Frequency AC Drives Inverter with Voltage 400VAC for Mixer Mixers are used in a wide range ...
AC Variable Frequency Inverter Drives VFD for Screw Feeder 400V Screw feeders are used in various ...
1000kw / 1250HP AC Variable Frequency Inverter Drives for Metalforming Metalforming is the process ...