Home Companies GANDO INTERNATIONAL (HONGKONG) LIMITED

400V Variable Frequency AC VFD Drives for Decanter Centrifuge

GANDO INTERNATIONAL (HONGKONG) LIMITED
Active Member

Contact Us

Address: 701 of NO.69, xilinxili, siming, xiamen, China

Phone: 86-013-2436807

Contact name:

Inquir Now

GANDO INTERNATIONAL (HONGKONG) LIMITED

400V Variable Frequency AC VFD Drives for Decanter Centrifuge

City & Province xiamen fujian
Categories Inverters & Converters
InquireNow

Product Details

400V Variable Frequency AC VFD Drives for Decanter Centrifuge

Decanter centrifuges are used to extract (dewater) solid materials from liquids when they are mixed together in slurry. Decanter centrifuges are used in many industrial applications such as:
1. Oil /solids separation (oil well drilling, refining, de-watering)
2. Industrial and biological wastewater treatment
3. Food processing (olive oil, wine, fruit juice)
4. Fish processing (fish meal, fish oil)
5. Chemical slurry
A main drive motor supplies power to turn the centrifuge. AC drives are commonly used to power the main drive motor. There are several different types of decanter centrifuges, such as: Vertical, horizontal, or scroll (conveyor).

 

Application Challenges

· Minimize the need for gears or belts to drive the centrifuge.

· Control and maintain speed during the decanting process

· Develop high torque at very low speeds.

· Two motor applications,  one for the bowl and one for the scroll.

· The bowl has a very high-reflected inertia.

· The scroll is usually in continuous regeneration,  as it runs at a slower speed than the bowl and is pulled along.

· Torque limiting on the scroll is very important.

· Some configurations require zero-speed operation of the scroll (differential gearbox).

· Dynamic braking or regenerative modules may be required if the bowl is NOT driven by a drive.

 

Features of G7 series matching decanter centrifuge application

Features

Benefits

Frequency Detection
Speed Agree

Both Frequency Detection and Speed Agree signals can interlock with primary and auxiliary machinery as well as safety equipment while the machine is operating.

Overtorque or Undertorque Detection

It is possible to notify the user of an impending fault before it occurs based on the Overtorque or Undertorque Detection settings.

Multi-Step Frequency Reference

Analog inputs are not required due to 17 possible Multi-Step Speeds. Operating speed can be adjusted for optimum performance.

  • Dwell Function
  • Stall Prevention
  • Feed Forward Function

For accelerating high inertia loads, the user can increase the Dwell Function setting and tune Stall Prevention. The Feed Forward function can also be used to assist in acceleration.

  • DC Injection Braking
  • High Slip Braking

Although the stop time is generally long due to a large inertia moment, it is still possible to quickly stop the drive without a braking resistor by using the DC Braking or the High Slip Braking function.

  • Accel/Decel Times
  • Intelligent Stall Prevention

Fast acceleration and deceleration times are possible by adjusting Accel/Decel times and using Intelligent Stall Prevention. This can reduce overall process time.

Fault Restart

The drive can automatically start after being shut off by using the Fault Restart function.

Flux Vector Motor Control

Provides high starting torque and good speed regulation.

Standard Motor Used

Standard NEMA B design motor can be used to eliminate specially designed motors.

Energy Saving Mode

Energy saving operation can be implemented at full speed during light loads.

 

Power range of G7 VFD

Voltage: 400VAC (380VAC – 460VAC)

Power: 22kw/30HP – 1000kw/1250HP

 

Specification of G7 VFD

Item

Specification

Input frequency

50/60Hz

Output frequency

0-400Hz

Overload current

150% rated current 1min.

Control mode

Close-loop vector control,  sensor-less vector control,  V/F control

Starting torque

150% 1hz (with PG 0hz)

Control precision

±0.2% (With PG ±0.02%)

Torque precision

±5%

Setting frequency resolution

Digital command 0.01hz; analog command 0.03hz/60hz

Output frequency resolution

0.01Hz

Frequency setting signal

-10V~+10V;0~+10V(20kΩ);4~20mA

Protection function

Over voltage, under voltage, over load, relay, overheat speed stall, grounding, instant power cut compensation( within 2 sec for operation mode. Continue to operate after the power is available), Charging protection( not to display when the dc voltage of main circuit is less than 50v)

Enclosure

IP20

Cooling mode

forced air cooling

Vibration

Less than 0.2g for 20hz

Ambient temperature / Humidity

-10 Degrees~+40 Degrees / 20~90%Rh (no condensation)

 

Tips:

A variable-frequency drive (VFD) is a system for controlling the rotational speed of an alternating current (AC) electric motor by controlling the frequency of the electrical power supplied to the motor. A variable frequency drive is a specific type of adjustable-speed drive. Variable-frequency drives are also known as adjustable-frequency drives (AFD), variable-speed drives (VSD), AC drives, microdrives or inverter drives. Since the voltage is varied along with frequency, these are sometimes also called VVVF (variable voltage variable frequency) drives.
 

Hot Products

1000kw / 1250HP AC Variable Frequency Inverter Drives for Metalforming Metalforming is the process ...
22kw – 1000kw Variable Frequency AC Inverter Drives for Conveyor Conveyors are used in a broad range ...
400V Variable Frequency AC VFD Drives for Decanter Centrifuge Decanter centrifuges are used to ...
Variable Frequency AC Drives Inverter with Voltage 400VAC for Mixer Mixers are used in a wide range ...
AC Variable Frequency Inverter Drives VFD for Screw Feeder 400V Screw feeders are used in various ...
Variable Frequency AC Drives Inverter with Voltage 400VAC for Mixer Mixers are used in a wide range ...