Results forabdominal ultrasound machinefrom 15212 Products.
|
GE 3.5C Convex Array Ultrasound Transducer 1. Type: Convex Array 2. Frequency: 2.0-5.0MHz 3. Compatible system: Logiq 3/ Logiq 5/ Logiq 7/ Logiq 9/ Logiq A5/ Logiq P5/ Logiq S6...
|
|
|
|
Ultrasonic System CX50 CX30 AC Adapter Power Supply Tectrol Imaging Device Medical Used CX50 CX30 AC Adapter Power Supply Tectrol 1. Part number: PN:453561367414 2. Compatible ...
|
|
|
|
Repair GE 3S-RS Pin/Repair Connector/Broken Pins/Locking Shafts Probe connectors are the piece of the probe that plugs into the ultrasound system. Most connectors are either ...
|
|
|
|
Siemens Acuson X300 PE premium The Siemens Acuson X300 PE premium is a mid-range Cardiovascular, Shared service ultrasound system intended to replace Siemens previous mid range ...
|
|
|
|
Hospital Facility Hitachi HI VISION 5500 EPI-A Board EG236707 Ultrasound Parts 1. Lead time: 1-3 days 2. Warranty: 60 days 3. Model: EG236707 Note: Different faults are also able ...
|
|
|
|
Siemens Acuson 4V1C Phased Array Transducer 1.Type:phased array 2.Frequency: 1.0-4.0 Mhz 3.Compatible system: Sequoia 512 GI, Sequoia C512, S2000 4.Application: cardiology, ...
|
|
|
|
Siemens 14L5 Linear Array Ultrasound Transducer Maintenance Crystal Array and Housing Replacement Model: Siemens 14L5 Fault description: aging of jacket, aging and deformation of ...
|
|
|
|
Samsung L3-12A Ultrasound Transducer Probe Strain Relief Maintenance Model: Samsung L3-12A Fault Phenomenon: can not be tested on the machine, the lens is damaged, the strain ...
|
|
|
|
S5-1 Linear Array Ultrasound Transducer Probe Crystal Array Replacement Model: S5-1 Fault description: The lens is completely blistered, and the image on the machine is disturbed. ...
|
|
|
|
GE E8C-RS Ultrasound Transducer Crystal Array Replacement and Connector Housing Repair Model: GE E8C-RS Fault Phenomenon: The connector housing is degummed and slightly worn, the ...
|
|
|
|
GE M3S Ultrasound Transducer Crystal Array and Connector Housing Replacement Model: GE M3S Fault Phenomenon: The connector housing is worn and loose, the lens is blistered, and ...
|
|
|
|
Toshiba PLT-8-5AT Linear Array Ultrasound Transducer Probe Connector Housing and Crystal Array Replacement Model: Toshiba PLT-805AT Fault description: The connector housing is ...
|
|
|
|
GE IC5-9-D Ultrasound Transducer Crystal Array Replacement Cable and Strain Relief Repair Model: GE IC5-9-D Fault Phenomenon: It has been repaired, the connector housing is ...
|
|
|
|
Toshiba PVT-375BT Ultrasound Transducer Connector Housing/Crystal Array/Cable Replacement 1. Model: Toshiba PVT-375BT 2. Fault Phenomenon: The cable is wrapped with tape, the ...
|
|
|
|
Probe Repair GE 4C Convex Probe Ultrasound Transducer Miantenance Model: GE 4C Fault Phenomenon: The cable is aging and broken, the strain relief is aging, the connector housing ...
|
|
|
|
GE RIC5-9A-RS 4D Ultrasound Probe Repair Crystal And Dome Replace 4D And Circuit Repair GE RIC5-9A-RS Repair Crystal and Dome Replace 4D and Circuit Model: GE RIC5-9A-RS Fault ...
|
|
|
|
Samsung L3-12A Ultrasound Probe Transducer Replace Strain Relief/Cable and Lense Model: Samsung L3-12A Fault Phenomenon: The cable is wrapped with tape, the cable is aged and ...
|
|
|
|
Samsung CA1-7A Ultrasound Probe Transducer Replace Strain Relief/Cable and Lense Model: Samsung CA1-7A Fault Phenomenon: The cable is wrapped with tape, the cable is aged and ...
|
|
|
|
Samsung CA2-8AD Ultrasound Probe Transducer Replace Strain Relief and Cable Model: Samsung CA2-8AD Fault Phenomenon: The cable is wrapped with tape, the cable is aged and broken, ...
|
|
|
|
Crystal/Cable/Strain relief Replacement for L12-3 Linear Array Ultrasound Transducer Probe Model: L12-3 Fault description: cable and strain relief aging, lens damage, housing ...
|
|
|