Not go gauges for caps on finished lamps B22, 7006-10-8 According to standard IEC 60061-3 Purpose: To check dimension A in, of caps B22 on finished lamps. Testing: Caps on finished lamps shall be assumed to be correct if ...
|
|
|
|
E14 Lampholders Gauge Screw Lamp Holder Gauges 7006-25-7 IEC60061-3 E14 lampholder gauge list 7006-25-7 Go Gauges for screw threads of lampholders E10 E14 E40 7006-26-4 NOT GO ...
china
|
|
|
|
Fa8 Not Go Gauge for Single-pin Cap, 7006-40A-1. Purpose: For the control of dimension E min. of sheet 7004-57. Testing: When the gauge is applied to the pin of the cap, the ...
|
|
|
|
E14 Lampholders Gauge Screw Lamp Holder Gauges 7006-25-7 IEC60061-3 E14 lampholder gauge list 7006-25-7 Go Gauges for screw threads of lampholders E10 E14 E40 7006-26-4 NOT GO ...
china
|
|
|
|
IEC60061-3: 7006-52-1 Gauge for Finished Lamps Fitted with E40 Caps for Testing Contact Making The gauge is shown in the test position. In the rest position the plunger shall be ...
|
|
|
|
IEC60061-3: 7006-28D-1 E40 No Go Gauge for Caps on Finished Lamps Purpose: To check the minimum outside (major) diameter of the screw thread, dimension d, of E40 caps on finished ...
|
|
|
|
IEC60061-3: 7006-24C-1 E39 No Go Gauge for Caps on Finished Lamps The drawing is intended only to illustrate the essential dimensions of the gauge. For details of cap E39, see ...
|
|
|
|
Go gauge for bi-pin cap on finished lamp G13, 7006-45-4 Purpose: To check dimensions E max., F min., F max. and the combined pin diameter and displacement of pins (including bosses...
|
|
|
|
Go gauge for caps on finished lamps E12, 7006-27H-1 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E12 caps on finished lamps. Testing: ...
|
|
|
|
Gauge for testing the retention of B22d caps in the holder, 7006-4B-1 According to standard IEC 60061-3 Purpose: To check cap dimensions for retention of the cap on the finished ...
|
|
|
|
Gauge for testing the retention of B15d caps in the holder, 7006-4B-1 According to standard IEC 60061-3 Purpose: To check cap dimensions for retention of the cap on the finished ...
|
|
|
|
Go gauge for caps on finished lamps E17, 7006-27K-1 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E17 caps on finished lamps. Testing: ...
|
|
|
|
Go gauges for caps E26, E26/50x39, E26/51x39 & E26d, 7006-27D-3 Purpose: To check the maximum dimensions of the screw thread and dimension T1 minimum of E26, E26/50x39, E26/51x39 ...
|
|
|
|
IEC60061-3: 7006-25-7 E14 Go Gauges for Screw Threads of Lampholder The drawing is intended only to illustrate the essential dimensions of the gauge. For details of screw thread of ...
|
|
|
|
IEC60061-3: 7006-25-7 E40 Go Gauges for Screw Threads of Lampholders The drawing is intended only to illustrate the essential dimensions of the gauge. For details of screw thread ...
|
|
|
|
IEC60061-3: 7006-12B-2 B22 Not Go /Retention Gauge for Lampholders The drawing is intended only to illustrate the essential dimensions of the gauge. For details of holder B22, see ...
|
|
|
|
Not go gauges for caps on finished lamps B22, 7006-10-8 According to standard IEC 60061-3 Purpose: To check dimension A in, of caps B22 on finished lamps. Testing: Caps on finished ...
|
|
|
|
Not go gauges for caps on finished lamps B15, 7006-10-8 According to standard IEC 60061-3 Purpose: To check dimension A in, of caps B15 on finished lamps. Testing: Caps on finished ...
|
|
|
|
Go gauges for caps on finished lamps BA9, B15, BA15 & B22, 7006-11-8. According to standard IEC 60061-3 Purpose: To check dimensions A max., N min. D1 min., D1 max., and the ...
|
|
|
|
Gauges for testing the insertion of caps in lampholders B22, 7006-4A-2 According to standard IEC 60061-3 Purpose: To check B22 cap dimensions for insertion of the cap on the ...
|
|
|