Results for4d endovaginal ultrasound transducer repairfrom 5494 Products.
|
Samsung Medison 3DC2-6 Ultrasound Transducer Probe Strain Relief Replacement and Cable Repair Model: Samsung Medison 3DC2-6 Fault Phenomenon: The cable and strain relief are ...
|
|
|
|
Abdominal use Toshiba PVT-375BT ultrasound transducer 50mm convex array Description: The Toshiba PVT-375BT is a convex array ultrasound transducer. The Toshiba PVT-375BT has a ...
|
|
|
|
PH M2736A Compatible Fetal Probe Lemo 12pin Fetus Transducer CE ISO13485 Compatibility model: PH Category: Fetal Certifications: CE, ISO 13485 Connector Distal: Round, 12-Pin ...
|
|
|
|
GE Voluson S8 Ultrasound Probe C1-5-RS Convex Array Transducer Repair 1. Type: Convex 2.Compatible system: Logiq e R7, Logiq P9, Logiq Q e, Vivid iq, Voluson S8 3. Frequency: 1.5-5 ...
|
|
|
|
PH M2736A Compatible Fetal Probe Lemo 12pin Fetus Transducer CE ISO13485 Compatibility model: PH Category: Fetal Certifications: CE, ISO 13485 Connector Distal: Round, 12-Pin ...
|
|
|
|
GE Logiq E9 Ultrasound Probe ML6-15-D Linear Vascular Transducer Repair 1. Type: Linear 2.Compatible system: Logiq E9, Logiq S8, Vivid E9, Voluson E8 Expert 3. Frequency: 4.5-15 ...
|
|
|
|
GE Logiq P9 Ultrasound Probe ML6-15-RS Linear Array Transducer Repair 1. Type: Linear 2.Compatible system: Logiq e R7, Logiq P9, Logiq Q e, Vivid iq, Voluson S8 3. Frequency: 4-15 ...
|
|
|
|
GE Logiq 3 Ultrasound Probe 12L Linear Array Transducer Repair 1. Type: Linear 2.Compatible system: Logiq 3, Logiq 7, Logiq A5, Logiq P5, Logiq S6, Vivid 3, Vivid 4, Vivid 7 Expert...
|
|
|
|
GE Logiq e Ultrasound Probe 3S-RS Phased Array Transducer Repair 1. Type: Phased Array 2.Compatible system: Logiq e, Logiq i, Logiqbook XP, Vivid e, Vivid i, Vivid S5, Vivid S6 3. ...
|
|
|
|
GE Logiq E9 Ultrasound Probe ML6-15-D Linear Vascular Transducer Repair 1. Type: Linear 2.Compatible system: Logiq E9, Logiq S8, Vivid E9, Voluson E8 Expert 3. Frequency: 4.5-15 ...
|
|
|
|
GE Logiq E9 ML6-15-D Breast Ultrasound Probe Repair Linear Vascular Transducer 1. Type: Linear 2.Compatible system: Logiq E9, Logiq S8, Vivid E9, Voluson E8 Expert 3. Frequency: 4...
|
|
|
|
ClearVue 650 The ClearVue 650 ultrasound machine adds 4D to its line of ClearVue ultrasound systems. This is a shared service ultrasound machine that is an upgrade to the ClearVue ...
|
|
|
|
Siemens EC9-4 Endovaginal Transducer 1. Type: Endocavitary 2. Frequency: 4-9 Mhz 3. Compatible system: Antares 4. Application: Urology, Prostate, with DL-4 Connector, OB/GYN 5. ...
|
|
|
|
S8-3 Ultrasound Transducer Probe Repair Service Acoustic Lens Replacement Model: S8-3 Fault description: The connector cable and strain relief are aged, the lens is damaged, and ...
|
|
|
|
Probe Maintenance for GE 4C Ultrasound Transducer Lens Replacement Model: GE 4C Fault Phenomenon: The cable and strain relief are aging, the image on the computer has dark shadows, ...
|
|
|
|
Samsung EA2-11AR Ultrasound Transducer Probe Strain Relief Maintenance Model: Samsung EA2-11AR Fault Phenomenon: can not be tested on the machine, the lens is damaged, the strain ...
|
|
|
|
Samsung E3-12A Ultrasound Transducer Probe Crystal Replacement Probe Repair Model: Samsung E3-12A Fault Phenomenon: There are shadows in the echo, the crystal is broken, but there ...
|
|
|
|
Motor Repair GE RAB2-5-D 4D Probe Motor Control Failures Motor control failures If the array stops moving or gets stuck, the motor control function has failed and may need to be ...
|
|
|
|
GE IC5-9-D Wideband Endocavity Ultrasound Transducer Hospital Scanning Machine Discounted Medical Supplies GE IC5-9-D Wideband Endocavity Ultrasound Transducer 1. Type: Volume 2. ...
|
|
|
|
Ultrasound Transducer Samsung CA1-7AD Curved Array Probe Medical Equipment 1. Type: Curved Array 2. Applications: Abdominal, Obstetrics, Gynaecology 3. Frequency Range: 1.0 - 7.0 ...
|
|
|
You may also be interested in :