Home Companies Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

LCD 600v Three Phase Portable Energy Meter Tester 1000A

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China

Contact name:Andy

Inquir Now

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

LCD 600v Three Phase Portable Energy Meter Tester 1000A

Country/Region china
City & Province beijing beijing
Categories Other Electric Power Tools
InquireNow

Product Details

 

GF312D1 High precision three phase portable energy meter tester with smart scanning head & 1000a clamp on ct

GFUVE Electronics is a recognized world leader of Energy Reference Standards, Meter Test Boards, CT / PT Meter Field Testers, DC / AC Transfer Standards, Energy Meter Testing and our Automated Laboratory Energy Reference Systems. GFUVE Electronics is 100% committed to exceeding the requirements of its Customers through continual improvement of all our products and services.

GF312D1 Portable Electric Energy Meter Calibration Device is used to calibrate three phase, single phase, active and reactive watt meters. And it also can be used as voltage, current and power meter to measure AC parameters of three phase power line.It can measure wave distortion factor and 2nd to 63th harmonic wave. it is high precision 0.05%, measurement current 0-24A directly, 0-120A or 0-3000A with clamp on ct. 100A clamp on ct has software compensation, the precision can reach 0.05%.

Our electric meter testing equipment can perform instrument transformer testing, revenue protection, and meter site testing. Depending on the specific task you want to accomplish, electric meter testing equipment will obtain the statistical data you and your customers need. Inject rated current & voltage to check Energy meter measurements. Start Injection & Start Standard Meter for accuracy test. Start injection with 25% of rated current with phase shift 30 degrees. Standard meter will calculate actual injected Energy. After certain time (15 minutes), stop injection & standard meter in the same time.

 

 

Application

 

The devices used to calibrate electricity meters must be routinely verified themselves. That’s the only way to protect consumers. Laborelec’s working standards are well suited to the task. We can carry out calibration on your site, minimising disruption to your calibration routine.

Laborary has a fully equipped calibration equipment with the most accurate energy standard. It can furnish an extensive accreditation portfolio that is recognised internationally.

Electric Energy Laboratory
Metrological verification department
Petroleum and petrochemical enterprises
Steel and cement plant
Power commissioning company

Power plant
Power company
Electric power measurement department

 

 

FEATURES

  • Three phase active or reactive electricity energy meter
  • 4Measure I(current) of three phase or single phase
  • Measure active power of three phase or single phase
  • Measure reactive power of three phase or single phase
  • Measure apparent power of three phase or single phase
  • Measure power factor of three phase or single phase
  • Measure phase angle between voltage and current
  • Measure frequency of power line
  • Display vector diagram
  • Calibrate three phase, single phase, active or reactive meter error
  • Measure U(voltage) of three phase or single phase
  • Display waveform of U and I
  • Analyze and display content of harmonic of U and I
  • Store and check measured data
  • Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp
  • Measure CT variable ratio
  • Print the data of measurement on site

PARAMETERS

 

Electrical parameters 
Accuracy class0.05, 0.1%, 0.02%
Power supply220V ± 10% or 110V ± 10%, 50/60Hz ± 2Hz
Test Voltage 
Range0V-600V
Error±0.05% (30V-600V)
±0.1% (5V-30V)
Harmonic2nd-63st
Test Current 
Range (direct connection)20mA-20A
Error (direct connection)±0.05% (100mA-20A)
±0.1% (20mA-100mA)
Range (Clamp CT)10mA-3000A
Error (Clamp CT)±0.2% (100mA-3000A)
±0.5% (10mA-100mA)
Harmonic2nd-63st
Power measure error 
Active power (direct connection)±0.05% (0.1A-20A)
±0.1% (0.02A-0.1A)
Reactive power (direct connection)±0.1% (0.1A-20A)
Energy measure error 
Active energy (direct connection)±0.05% (0.1A-20A)
±0.1% (0.02A-0.1A)
Reactive energy (direct connection)±0.1% (0.1A-20A)
Phase angle 
Range0° ~ 360°
Resolution0.01°
Error±0.02°
Frequency 
Range40Hz-70Hz
Resolution0.001Hz
Accuracy0.002Hz
Power factor 
Range-1 ~ 0 ~ 1
Resolution0.0001
Error0. 0005
Pulse output 
Energy constant180000imp/kWh, 1800imp/kWh, 18imp/kWh
Pulse ratio1:1
Output level5V
Pulse input 
Input channel1
Input level5-24V
Input frequencyMax. 2MHz
Display 
Resolution6”TFT (640×480)
Function 
Vector diagramYes
WaveformYes
Energy accumulationYes
Communication portRS232
Communication with PCYes
Mechanical parameters 
Dimensions (W×H×D) (mm)390×200×160
Host Weight (mm)1.6
Weight (including Accessories 3pcs 100A clamp CT) (kg)12
Environmental conditions 
Ambient temperature-10°C to 40°C
Relative humidity30%-85%

Photo

Hot Products

LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...
S50 1200A 1mv/A and 1mA/A output AC Current Clamp on CT Description The round jaw design on the S50 ...
O100M 100MHz Oscilloscope voltage probe and Oscilloscope Ac current probe O100M 100MHz Oscilloscope ...
S120 1200A 1MV/A AND 1MA/A OUTPUT AC CURRENT CLAMP ON CT Description The S120 is a high performance ...
Q125B High Accuracy Current Clamp On Measuring Instrument Description The Q125B is a high performanc...
HQ46 CABLE TYPE 500A MV OUTPUT AC CLAMP ON CURRENT PROBE Description The HQ46 AC Current Probe is ...