Home Companies Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Programmable DC 30A 1000V Power Calibrator

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.
Active Member

Contact Us

[China] country

Address: Oriental HuaRui A, No. 150 Guanzhuang Road, Chaoyang District, Beijing, 100024, China

Contact name:Andy

Inquir Now

Beijing GFUVE Instrument Transformer Manufacturer Co.,Ltd.

Programmable DC 30A 1000V Power Calibrator

Country/Region china
City & Province beijing beijing
Categories Other Switches
InquireNow

Product Details

GF6019 Programmable DC Power Calibrator for calibration of DC voltage meter, DC current meter & DC power meter

 

Programmable DC sources are an imperative tool in any test or research lab due to the need to calibrate the plethora of devices that measure such signals. GFUVE's expertise in delivering high quality instrumentation is evidenced by the introduction of the GF6019, which combines high precision outputs, simple controls, and powerful features to meet all your calibration needs.
A high accuracy programmable DC power calibrator suitable for calibrating single-phase dc watt-meters, power meters, and kW-Hr meters. The GF6019D is a practical solution to precision power simulation, providing a simultaneous supply of voltage and current with phase control.
The GF6019 is designed calibration of traditional voltage and current measuring devices such as ammeters, voltmeters, digital multimeters, and DC wattmeters. In addition, the GF6019 is capable of calibrating temperature meters and controllers which measure temperature through thermocouples or Resistance Temperature Detector's (RTD).
A voltage source is a device which provides a constant voltage to load at any instance of time and is independent of the current drawn from it. This type of source is known as an ideal voltage source. Practically, the ideal voltage source cannot be made. It has zero internal resistance. It is denoted by this symbol. The graph represents the change in voltage of the voltage source with respect to time. It is constant at any instance of time.
 

FEATURES AND FUNCTIONS

  • Testing all kinds of DC energy meter, DC power meter
  • Testing all kinds of DC ammeter, DC voltmeter
  • DC current source and DC voltage source
  • User friendly menu guided operation
  • Especially configured USB stick for storage of customer data
  • Easy verification and analysis of DC meter
  • Automatic operation without need of an external PC
  • Accuracy class 0.02
  • 0-30A/0-1050V
  • Start testing and creep testing
  • DC power source integrated
  • Test by automatic or manual
  • 8 inch TFT touch screen
  • Recorder 10000 sets energy meter data
  • Overload, short circuit, open circuit protection
 

PARAMETERS

Electrical parameters 
Accuracy0.02%
Power SupplyOne Phase AC 180-265V, frequency 50/60Hz.
DC Voltage Output
Range65V, 250V, 500V, 750V, 1000V (max 1150V)
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.1% (Non-capacitive load)
Output load50VA
Full load regulation rate≤±0.01%RG
Accuracy±(0.03%RD+0.02%RG)
DC Current Output
Range0.001A, 0.005A, 0.02A, 0.05A, 0.2A, 1A, 3A, 10A, 20A, 30A,  (max 36A)
small signal 2.5mV, 20mV, 100mV, 1V, 5V
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s, small signal 2uV/min
Distortion≤0.1% (Non-capacitive load)
Output load1200VA
Full load regulation rate≤±0.01%RG
Accuracy±(0.02%RD+0.02%RG)
Externally attached shunt100mV
Accuracy±(0.02%RD+0.02%RG)
DC Power Output
power output stability<0.01%RG/120s
power accuracy±(0.02%RD+0.02%RG)
DC Power Energy Measurement Error
power energy±(0.02%RD+0.02%RG)
Power Pulse Output
Power Pulse Output20KHz (Full-Range)
Power Pulse Input
Energy pulse input20KHz
Ripple output20-500Hz ripple output
Communication portUSB port, RS232, 10/100M LAN
Mechanical parameters 
Dimensions (W×D×H) (mm)430x400x250
Weight (kg)12
Environmental conditions 
Ambient temperature-10°C to +40°C
Relative humidity-30°C to 60°C
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.

PHOTO

 

Hot Products

LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...
LZCK Series Weatherproof Outdoor Split-core Current Transformer IP68 0.5S Power Distribution line ...
12KV Hydrophobic Cycloaliphatic Epoxy Cast Medium Voltage Outdoor Potential Transformer Applications ...
S50 1200A 1mv/A and 1mA/A output AC Current Clamp on CT Description The round jaw design on the S50 ...
O100M 100MHz Oscilloscope voltage probe and Oscilloscope Ac current probe O100M 100MHz Oscilloscope ...
S120 1200A 1MV/A AND 1MA/A OUTPUT AC CURRENT CLAMP ON CT Description The S120 is a high performance ...