GF438II Portable Three Phase Power Quality Analyzer

 

GFUVE GF438II Three phase power quality analyzers can help you discover the state of health of your power systems. Designed to meet the needs to the intended measurement task, power quality analyzers help you beprepared for any power quality issues.The Power Quality analyzers that can monetize the cost of energy waste due to poor power quality. More powerful sampling options, greater accuracy and larger memory makes the GF438II better for longer term, higher resolution or more demanding power quality studies.

 

The GFUVE GF438II power quality analyzer enables you to identify issues and measure energy loss giving you specific insight into the amount of loss in dollars associated with things like effective power and withpoor power quality characteristics such as reactive power, unbalance, distortion, or neutral current. To maintain the health and safety of such infrastucture, a reliable power quality analyzer is needed. This power quality analyzer should be capable of not only logging single to multi-phase power, but also trend and monitor anomalies in the power system such as voltage sags,swells and dips, as well as flicker, inrush current, and demand changes.

 

A power quality compression algorithm is an algorithm used in the analysis of power quality. To provide high quality electric power service, it is essential to monitor the quality of the electric signals also termed as power quality (PQ) at different locations along an electrical power network .
The POWER QUALITY ANALYZER GF438II provide robust support for field personnel who need to analyze power characteristics in the form of measurement capabilities that reliably captures the full range of power anomalies and exceptional ease of use throughout the entire user experience, from connecting the instrument to recording data.

 

GF438II handheld three phase power quality analyzer offer the best ability in power quality analysis, GF438II handheld power quality analyzer help locate, predict, prevent and troubleshoot power quality problems in three phase and single phase power distribution systems. Additionally, GFUVE patented energy loss algorithm, unified power measurement, measuring and counting energy losses due to harmonics and unbalance issues, allowing the user to pinpoint the origin of energy losses in the system.

 

The GFUVE GF438II power quality analyzers are designed for users who need to get to the solution of the power quality problem as quickly as possible so that they can minimize expensive downtime.

  • Measure multiple parameters simultaneously to quickly understand overall power quality health
  • View data as simple digital values or more detailed trend graphs that give you fast insight into changes over time, waveforms, and phasor diagrams
  • Organize data in tabular format so you can quickly correlate parameters like magnitude, duration, and time to the issues you are experiencing in your facility

FEATURES

  • 3s statistical interval, continuously record 728h
  • Support multi-brand current transformer
  • Up to 32G data storage space
  • Record up to 461 power energy parameters simultaneously
  • Up to 10000 screenshots saved
  • Support periodic recording function
  • Up to 3.9M/s USB high-speed transfer
  • Recording wave
 

FUNCTIONS

  • Energy loss calculator: classic active and reactive power measurements, unbalance and harmonic power, are quantified to pinpoint true system energy losses in dollars (other local currencies available).
  • Power inverter efficiency: simultaneously measure AC output power for power electronics systems.
  • Power wave data capture: GF438II analyzers capture fast RMS data, show half-cycle and waveforms to characterize electrical system dynamics (generator start-ups, UPS switching etc.).
  • Waveform capture: GF438II capture 50/60 cycles (50/60Hz) of each event that is detected in all modes, without set-up
  • Automatic transient GF438II analyzers capture 200 kHz waveform data on all phases simultaneously up to 1000V.
  • Fully class-A compliant: GF438II analyzers conduct tests according to the stringent international IEC 61000-4-30 class-A standard.
  • Mains signaling: GF438II analyzer measure interference from ripple control signals at specific frequencies.
  • Troubleshoot: analyze the trends using the cursors and zoom tools.
  • Highest safety rating in the industry: 600 V CAT IV/1000 V CAT III rated for use at the service entrance.
  • Measure all three phases and neutral: with included four flexible current probes with enhanced thin flex designed to fit into the tightest places.
  • Automatic trending: every measurement is always automatically recorded, without any set-up.
  • System-monitor: ten power quality parameters on one screen according to EN50160 power quality standard
  • Logger function: configure for any test condition with memory for up to 600 parameters at user defined intervals.
  • View graphs and generate reports: with included analysis software.
  • Battery life: up to 6 hours operating time per charge on Li-ion battery pack.
 

PARAMETERS

Measurement line typeSingle-phase 2-wire, Single-phase 3-wire, Three-phase 3-wire or Three-phase 4-wire plus one extra input channel for voltage, current, power measurement (AC or DC measurement)
Voltage rangesVoltage measurement: 1000.00 V rms
Transient measurement 6.0000 kV peak
Current ranges10.00 mA to 6.0000 kA AC (depends on current sensor in use)
Power ranges3.00 W to 6.0000 MW (determined automatically based on voltage and current range in use)
Basic accuracyVoltage: ±0.1% of nominal voltage
Current: ±0.1 % rdg. ±0.1 % f.s. + current sensor accuracy
Active power: ±0.2 % rdg. ±0.1 % f.s. + current sensor accuracy
Measurement items1. Transient voltage : 2 MHz sampling
2. Frequency cycle : Calculated as one cycle, 40 to 70 Hz
3. Voltage (1/2) RMS: one cycle calculation refreshed every half cycle
Current (1/2) RMS: half-cycle calculation
4. Voltage swell, Voltage dips, Voltage interruption
5. Inrush current
6. Voltage waveform comparison
7. Instantaneous flicker value: As per IEC61000-4-15
8. 200 ms frequency: Calculated as 10 or 12 cycles,40 to 70 Hz
9. 10 sec frequency: Calculated as the whole-cycle time during the specified 10 s period, 40 to 70 Hz
10. Voltage waveform peak, Current waveform peak
11. Voltage, Current, Active power, Apparent power, Reactive power, Active energy, Reactive energy, Power factor, Displacement power factor, Voltage unbalance factor, Current unbalance factor, and efficiency
12. High-order harmonic component (voltage/ current): 2 kHz to 80 kHz
13. Harmonic/ Harmonic phase angle (voltage/ current), Harmonic power: 0th to 50 th orders
14. Harmonic voltage-current phase angle: 1th to 63 th orders
15. Total harmonic distortion factor (voltage/ current)
16. Inter harmonic (voltage/ current): 0.5 th to 62.5 th order
17. K Factor (multiplication factor)
18. IEC Flicker, Δ V10 Flicker
RecordRepeated ON: 1 year, Maximum recording event: 9999 × 366 days (up to 9999 events per day)
Repeated off: 35 days, maximum recording event: 9999 events
InterfacesSD/SDHC memory card, LAN (HTTP server function / FTP function), USB2.0 (for communication)
Display6.5-inch TFT color LCD (640 × 480 dots)
Power supplyAC adapter (100 V to 240 V AC, 50/60 Hz, rated current 1.7 A), Battery Pack (Continuous use: 180 minutes, Charging time: Max. 6hr 30 m with AC adapter)
Dimensions and mass300 mm (11.81 in)W × 211 mm (8.31 in)H × 68 mm (2.68 in)D, 1.6 kg (91.7 oz) (including Battery Pack )

 

 

Hot Products

LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...
Outdoor split core current transformer 3000A LZCK series outdoor waterproof current transformers are ...
LZCK-36 OUTDOORS SPLIT CORE CURRENT TRANSFORMER Description The model LZCK-36 outdoor split core ...
Split Core Current Transformer LZCK185-10 LMCK series outdoor current transformers are applicable ...
LZCK-55 IP67 Outdoor split core current transformer 200/5A 0.5S for three Phase Watthour meter LZCK...
LZCK-55 IP65 Proofwater Split Core Current Transformer for Measurement Introduction LZCK series ...