GF312D1 0.05% Accuracy 576V 120A Portable Three Phase Electric Meter Calibrator With 100A clamp on ct

 

 

GF312D1 Portable Three Phase Electric Meter Calibrator With 100A clamp on ct is a precision AC energy meter testing instrument, mainly used to test three phase energy meter error on site and measure all various of AC parameters.

 

Calibration of electricity meters An electricity meter or a watthour meter measures the electrical energy passing through the meter and may be single-phase or poly-phase.

 

Application

 

The devices used to calibrate electricity meters must be routinely verified themselves. That’s the only way to protect consumers. Laborelec’s working standards are well suited to the task. We can carry out calibration on your site, minimising disruption to your calibration routine.

Laborary has a fully equipped calibration equipment with the most accurate energy standard. It can furnish an extensive accreditation portfolio that is recognised internationally.

 

FEATURES

  1. Three phase active or reactive electricity energy meter.
  2. Calibrate three phase, single phase, and active or reactive meter error.
  3. Measure U(voltage) of three phase or single phase.
  4. Measure I(current) of three phase or single phase.
  5. Measure active power of three phase or single phase.
  6. Measure reactive power of three phase or single phase.
  7. Measure apparent power of three phase or single phase.
  8. Measure power factor of three phase or single phase.
  9. Measure phase angle between voltage and current.
  10. Measure frequency of power line.
  11. Display vector diagram.
  12. Display waveform of U and I.
  13. Analyze and display content of harmonic of U and I.
  14. Measure 2-64 harmonic of U, I.
  15. Store and display measured data.
  16. Optional 5A, 20A, 100A, 500A, 1000A, 2000A, 3000A current clamp.
  17. Measure CT variable ratio.
  18. Measure the ratio or lag-angle of low-voltage transformer.
  19. Adopt 32 bit ARM processor, multi-channel 16 bit precision A/D convertor, high resolution TFT color LCD.
  20. Inner equipped with 0.01% wide-range current transformer and can be equipped with various type current clamps, wide range of measurement and high veracity.
  21. Low consumption circuit design, high energy Lithium battery supply, intellectual power management software, which enables the instrument continuously working up to 10 hours.

 

 

PARAMETERS

 

Electrical parameters 
Accuracy class0.05%, 0.1%
Resolution6”TFT (640×480)
Power supply220V±10%, 50/60Hz
Li-polymer battery (size (mm): 110x51x16, nominal output voltage: 7.2V, capacity: 5000mAh)
Power line supply (U1, UN), 85V-265V 50/60Hz
Communication portRS232
Test voltage 
Range0-480V
Error±0.05% (30V-480V)
 ±0.1% (5V-30V)
Harmonic2nd-64st
Test current 
Range (direct connection)5mA-20A
Error (direct connection)±0.05% (100mA-20A)
±0.1% (10mA-100mA)
Range (clamp CT)10mA-3000A
Error (camp CT)±0.2% (100mA-100A)
±0.5% (100A-3000A)
Harmonic2nd-64st
Power measure error 
Active power (direct connection)±0.05% (0.1A-20A)
±0.1% (0.01A-0.1A)
Reactive power (direct connection)±0.1% (0.1A-20A)
Energy measure error 
Active energy (direct connection)±0.05% (0.1A-20A)
±0.1% (0.01A-0.1A)
Reactive energy (direct connection)±0.1% (0.1A-20A)
Phase angle 
Range0o-360o
Resolution0.01o
Error±0.05o
Frequency 
Range45-65Hz
Resolution0.001Hz
Error0.002Hz
Pulse input 
Input channel2
Input level5-24V
Input frequencyMax. 2MHz
Pulse output 
Energy constant180000imp/kWh, 1800imp/kWh, 180imp/kWh
Pulse ratio1:1
Output level5V
Function 
Vector diagramYes
WaveformYes
Energy accumulationYes
Communication with PCYes
Mechanical parameters 
Instrument dimensions (W×H×D) (mm)245×162×60
Instrument Weight (kg)1.8
Carry case dimensions (W×H×D) (mm)450×320×185
Carry case (kg)10.6
Environmental conditions 
Ambient temperature-10°C to 55°C
Relative humidity15%-85%

 

 

Hot Products

LZCG530-10 Protection relay device using 5P20 50/1A Zero Sequence Current Transformer Zero Sequence ...
LZCG530-10 Zero Phase Current Transformer, Ring net cabinet 5P10 Ratio 100A / 1A Zero Sequence ...
LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...
Q110 4mm Banana connector 1000A/5A Split Core AC Clamp on Current Transformer with 110mm & 50m ...
IP68 200/5A High Magnetic Core Clamp Ct Transformer / Split Core CT For Electric Meter http://www...
200A Outdoor Split Type Current Transformer For Cable Fault Monitoring , Class 0.5 200A Outdoor ...