Six Phase High Performance Protection Relay Test Kit

 

 

 

Test-630 is a six phase current output and six phase voltage output protection relay tester with 5.Eight pairs of binary input and four pairs of binary output.

The multiple protection function of today’s protection relay systems requires a new level of sophisticated test hardware and software to completely analyse the operation of the unit in a real life situation. Every facet of relay testing can be handled with the comprehensive line of relay test equipment from GFUVE.
Small as it is, Super-function protection relay test set is capable of dealing with all types of tasks which used to be conducted by heavy conventional relay test kit. In that sense, GFUVE’s portable and comprehensive TEST-630 can live up to its reputation as a colossus.

 

Parameters

 

Electrical parameters 
Allowable rangeAC220V±10% or AC110V±10%, 50/60Hz±10%
Time measurement0.1ms-999999.999s
AC current output 
Phase current output (effective value)6×0-30A or 3 × 0-60A
Maximum output power520VA/phase
Maximum parallel current output (effective value)0-180A
Long-term allowable working value of phase current (effective value)>10A
Allowable working time of maximum current>11s
Accuracy<±0.2%
AC voltage output 
Phase voltage output (effective value)6×0-130V
Line voltage output (effective value)0-260V
Maximum output power70VA/phase
Accuracy<±0.2%
DC voltage output 
Output range0-300V or 6×0-±130V
Maximum output power130VA
Accuracy<±0.2%
DC current output 
Output range-10-10A or 6×0-±10A
Maximum output power150VA
Accuracy<±0.2%
Binary input 
Idle contact1-20mA, 24V (DC)
Electric potential contact0-250V (DC)
Binary output 
Idle contact250V/0.5A (DC)
Rated output 
Frequency error<±0.01HzHz
Phase error<±0. 2°
Waveform distortion<±0.3% (fundamental wave)
Time error<40µs
Output frequency0-1050Hz
Superposed harmonic wave0-21times
Time measurement 
Test range0.1ms-999999.999s
Mechanical parameters 
Dimensions (L×W×H) (mm)360×195×365
Weight (kg)16.6
Environmental conditions 
Use range0°C to 45°C
Storage range-25°C to 70°C

 

Test Item

 

1 . U/I Test
2 . DC Test
3 . Impedance Characteristics
4 . Power Direction Test
5 . I-T Test
6 . Differential Relay
7 . Harmonic Test
8 . Differential Protection
9 . Distance Protection
10 . Zero Sequence Protection
11 . Setting Group Test
12 . State Sequence
13 . Synchronization Test
14 . Special Test
15 . Oscillation Test
15 . Metering Instrument
16 . Hardware Checkout
17 . Low Voltage Protection

 

 

 

The Product picture:

 

Hot Products

LZZT620-10 resin cast Three phase bushing type Zero Sequence Current Transformer for protection ...
LZZT943-10 resin cast Three phase Zero Sequence Current Transformer for Ring cabinet and inflatable ...
150mm diameter 2000A/1A 5P20 Cast Resin Zero Sequence Current Transformer with IEC 61869-2 LZCK2501 ...
LZCG530-10 Protection relay device using 5P20 50/1A Zero Sequence Current Transformer Zero Sequence ...
LZCG530-10 Zero Phase Current Transformer, Ring net cabinet 5P10 Ratio 100A / 1A Zero Sequence ...
LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...