P50-3 Electronics power quality analyzer 1000A Clamp On Current Transformer Amp Clamp 40Hz - 2000Hz For Voltage Output
 
Current clamps are typically used to read the magnitude of alternating current (AC) and, with additional instrumentation, the phase and waveform can also be measured.
 
The GFUVE AC-only Current Sensor P50-3 apply current measurement for direct readings on DMM's, loggers, Best-in-class bandwidth up to 200mHz. They are built to the latest safety and performance standards, and carry the CE mark.
 
GFUVE Clamp-on Current Transformer are designed for fast and easy installation.Clamp-on Current Transformer uses Permalloy magnetic core or Silicon and amorphous core, with characteristics of small size, high precision, good stability and strong anti-interference ability.
 
Why Choose GFUVE Current Probes. The Most Comprehensive Line of Current Probes. GFUVE ® the world's largest supplier, offers current probe models capable of accurately measuring from the low µA to kA range. A wide variety of configurations and jaw sizes are available. Probe types include iron core, Hall Effect, Flux Gate, and Rogowski etc.
 
GFUVE Current transformer clamp meters are equipped with rigid jaws of made of ferrite iron. The jaws are individually wrapped by coils of copper wire. Together, they form a magnetic core during measurements. Their basic operation is like that of a transformer. It works with one primary turn, or winding, which in nearly all cases is the conductor .
 
 
 
Features
 
Measurement range of 1mA to 1200A AC
Large jaw opening accommodates conductors up to two 500kcmil
Improved ergonomic design and easy operation
High content nickel metal core
Conforms to EN 61010, 600V CAT III
Low phase shift for power measurement
Designed for DMMs, recorders, loggers, oscilloscopes, power and harmonic meters
UL, CE mark
 
 
Applications
 
Power quality measuring
Large industrial loads
Measuring around cable bundles
Power load monitoring
Waveform analysis
Energy meter calibrator
 
 
Parameter
 

Electrical parameters
Ratio1000: 1 or 2000:1 (customized)
Accuracy class0.1%, 0.2%, 0.5%
Primary current0 - 1000A AC
Secondary output1mV/A AC, 5mV/A or (customized)
Max. Cont. Input current1200A
Over voltage categoryCAT III 600V
Output signal333mV, 500mV,1V,2V,5V AC at nominal input current
Accuracy (1000A Range)
0-10A≤0.5%
10-100≤0.2%
10-1200A≤0.1%
Phase Shift(1000A Range)
0-10A≤0.5°
10-100≤0.2°
100-1200A≤0.1°
Frequency range40Hz-2000Hz
Dielectric strength3KV 50Hz/60Hz at 1 minute
Temperature range-20°C to +55°C
Output2.5 meter cable with D01 connector
Max. voltage not insulated conductors600 V
StandardEN 61010-1, EN 61010-2-032, IEC60044-1
InstallationClamp type
Output modeLead output (2.5m)
Mechanical parameters
Dimensions (L x W x H) (mm)102.9 x 219.6 x 28
Weight (g)550
Holding wire diameter (mm)φ50
Max. jaw opening (mm)50
ColorGray or blue
MaterialPC+ABS+Polycarbonate, UL94 V0

 
Selection

ModelRate CurrentMax CurrentSecondary VoltageCoil RatioBurden ResistanceAccuracy
P50V1-10001000A1200A1V1000:1customized0.1%
P50V2-10001000A1200A2V1000:1customized0.1%
P50V4-10001000A1200A4V1000:1customized0.1%
P50V5-10001000A1200A5V1000:1customized0.1%
P50V10-10001000A1200A10V1000:1customized0.1%
P50V1-500500A600A1V1000:1customized0.2%
P50V2-500500A600A2V1000:1customized0.2%
P50V4-500500A600A4V1000:1customized0.2%
P50V5-500500A600A5V1000:1customized0.2%
P50V10-500500A600A10V1000:1customized0.2%

 
FAQ, following questions will help you to select the matched probe for your applications.
1. Please determine if you are measuring AC or DC?
GFUVE P50-3 is for AC measuring. If DC, we have hall effect models to suggest.
 
2. What is the maximum current you will measure?
P50-3 maximum current is 1200A
 
3. What size conductor will you clamp onto? This parameter determines the probe jaw size needed.
P50-3 can clamp conductor diameter size is 50mm
 
4. What type of probe output do you need or can you work with (mA, mV, A, AC, etc.)?
P50-3 can customize output with mA, mV. A, V.
 
5. What is the working voltage of the conductor to be measured?
GFUVE probes should be used below 600 volts
 
6. What type of termination do you need: jacks, leads or BNC?
P50-3 standard has 2.5meter leads. We can offer jacks or BNC… as options.
 
7. If you cannot find information you need or would like assistance, contact us today. We have designed many more probes than those shown in this catalog, and we manufacture in Beijing, China.
 
 
 
Photos

 

Hot Products

LZZT620-10 resin cast Three phase bushing type Zero Sequence Current Transformer for protection ...
LZZT943-10 resin cast Three phase Zero Sequence Current Transformer for Ring cabinet and inflatable ...
150mm diameter 2000A/1A 5P20 Cast Resin Zero Sequence Current Transformer with IEC 61869-2 LZCK2501 ...
LZCG530-10 Protection relay device using 5P20 50/1A Zero Sequence Current Transformer Zero Sequence ...
LZCG530-10 Zero Phase Current Transformer, Ring net cabinet 5P10 Ratio 100A / 1A Zero Sequence ...
LZCK2500-10 120mm 50/5a Resin Casting Split core Protection Zero Sequence Current Transformer 5P20 ...