【Wide Range】Both indoor and outdoor can be used. Soil Nutrient
Meter Soil Hygrometer Moisture Senso can be used for your garden,
Vegetable Garden,Orchards,Greenhouse, Farm, Lawn, potted plants,
succulent plants, etc.
LED Display for Clear Readings: Equipped with an LED screen, the
Yieryi Soil Tester offers clear and easy-to-read results, even in
low light conditions. The large display ensures that nutrient
levels, temperature, Nitrogen/Phosphorus/Potassium content are
visible at a glance.
Soil Nitrogen meter Range: With a measurement range of 0-1999
mg/kg, Measuring temperature is -30°C to 80°C,Suitable for Farming,
Orchards, vegetables.
Press the on button to turn on:
Quick test method: First will be tested soil measuring point, with
purewater (or distilled water) poured through at least 10CM depth
(the besthumidity 70-80%),and then the instrument metal probe,
verticallyclockwise inserted in about 8cm depth of wet soil, so
that the soil andprobe metal surface easy and uniform contact,
response time is about 10seconds or so, the number displaved by the
instrument, That is the actuameasurement value, The tightness of
the soil will directly affect the errorof the measurement value, so
it is required that the multi-pointmeasurement of the above method
must be carried out at differentmeasuring points to order the
average value.
lmmediately after each measurement, clean the surface of the
metaprobe with a paper towel or cleaning cloth until the instrument
returnsto a state that displays zero values.
Calibration method:under normal circumstances,before theinstrument
leaves the factory, the factory has calibrated, the user doesnot
need to recalibrate.
The instrument metal probe inserted in the soil or paste soil
(otheimeasured media) should not be too long, so as to avoid
oxidation andwater seepage,thereby damaging the metal surface and
internalstructure of the probe, resulting in inaccurate or unstable
measurementdata of the instrument, At the end of each use of the
instrument, it isnecessary to use a grinding cioth (clean cloth)or
wet paper towel tocompletely remove the residual objects on the
surface of the metaprobe in time, and blot the surface of the metal
probe with paper towels
After use, press the switch key to shut down, clean the electrode
toreduce pollution after saving.
When the instrument is not in use,it is necessary to put on
theprotective cap on the metal probe, do not rub the surface of the
metalprobe directly with your hand, and keep it clean and dry, away
frommagnetic objects and other metal objects.
During use, insert the electrode into the soil to avoid collision
withhard objects as much as possible.
After the low battery alarm, replace the battery in time to ensure
thenormal use of the product