Home Companies Zhenglan Cable Technology Co., Ltd

Overhead Power Transmission Bison Dog Wolf Rabbit Aluminum Conductor Steel Reinforced BS 215-2 BS EN 50182

Zhenglan Cable Technology Co., Ltd

Contact Us

[China] country

Trade Verify

Address: Room 4916, Floor 49, South Tower of Greenland Center, East Zhengzhou district, Zhengzhou, China

Contact name:Linda Yang

Inquir Now

Zhenglan Cable Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Overhead Power Transmission Bison Dog Wolf Rabbit Aluminum Conductor Steel Reinforced BS 215-2 BS EN 50182

Country/Region china
City & Province zhengzhou henan
Categories Other Wires, Cables & Cable Assemblies
InquireNow

Product Details

Bare Overhead Power Transmission Conductor Bison Dog Wolf Rabbit Aluminum Conductor Steel Reinforce BS 215-2 BS EN 50182​

 

APPLICATION

ACSR conductors used as bare overhead transmission cable and as primary and secondary distribution cable. ACSR offers optimal strength for line design. Variable steel core stranding enables desired strength to be achieved without sacrificing ampacity.

STANDARD

Basic design to BS 215-2 / BS EN 50182 / IEC 61089 / ASTM B 232/B 232M / DIN 48204 / JIS C 3110 standards.

 

CONSTRUCTION

ACSR conductors are formed by several wires of aluminium and galvanized steel, stranded in concentric layers. The wire or wires which form the core, are made of galvanized steel and the external layer or layers, are of aluminium. Galvanized steel core consist normally of 1, 7 or 19 wires. The diameters of steel and aluminium wires can be the same, or different.

By varying the relative proportions of aluminium and steel, the required characteristics for any particular application can be reached. A higher U. T. S. Can be obtained, by increasing steel content, and a higher current carrying capacity by increasing aluminium content.

 

TECHNICAL DATA

Numbers of WiresModules of ElasticityCoeficient of linear Expansion
ALSTEELKg/mm2Lb/in21/Cº1/Fº
618111.5 x10619.1 x10-610.6 x10-6
677711.0 x10619.8 x10-611.0 x10-6
12710715.2 x10615.3 x10-68.5 x10-6
181679.5 x10621.2 x10-611.8 x10-6
2477410.5 x10619.6 x10-610.9 x10-6
2677710.9 x10618.9 x10-610.5 x10-6
2877911.2 x10618.4 x10-610.2 x10-6
3078211.6 x10617.8 x10-69.9 x10-6
30198011.4 x10618.0 x10-610.0 x10-6
32198211.7 x10617.5 x10-69.7 x10-6
547709.9 x10619.3 x10-610.7 x10-6
5419689.7 x10619.4 x10-610.8 x10-6

 

CONSTRUCTION PARAMETERS

• IEC 60189

CodeNominal AreaStrandingOverall DiameterWeightBreaking LoadElectrical Resistance @20°Current Rating*
 ALSTEELTOTALALSTEEL     
 mm2mm2mm2No.xmmNo.xmmmmKg/KmKNΩ/KmA
16162.6718.76/1.841/1.845.5264.66.081.793485
25254.1729.26/2.301/2.306.9100.99.131.1478112
40406.6746.76/2.911/2.918.73161.514.40.7174150
636310.573.56/3.661/3.6610.98254.421.630.4555198
10010016.71176/4.611/4.6113.83403.834.330.2869263
1251256.9413218/2.971/2.9714.85397.929.170.2304299
12512520.414526/2.477/1.9215.64503.945.690.231302
1601608.8916918/3.361/3.3616.8509.336.180.18347
16016026.118626/2.807/2.1817.74644.957.690.1805351
20020011.121118/3.761/3.7618.8636.744.220.144398
20020032.623326/3.137/2.4319.81806.270.130.1444402
25025024.627522/3.807/2.1121.53880.668.720.1154458
25025040.729126/3.507/2.7222.161007.787.670.1155461
31531521.833745/2.997/1.9923.911039.679.030.0917526
31531551.336626/3.937/3.0524.871269.7106.830.0917530
40040027.742845/3.367/2.2426.881320.198.360.0722607
40040051.945254/3.077/3.0727.631510.3123.040.0723610
45045031.148145/3.577/2.3828.561485.2107.470.0642651
45045058.350854/3.267/3.2629.341699.1138.420.0643655
50050034.653545/3.767/2.5130.091650.2119.410.0578693
50050064.856554/3.437/3.4330.871887.9153.80.0578697
56056038.759945/3.987/2.6531.831848.2133.740.0516741
560*56070.963154/3.6319/2.1832.682103.4172.590.0516745
63063043.667445/4.227/2.8133.752079.2150.450.0459794
630*63079.871054/3.8519/2.3134.652366.3191.770.0459798
71071049.175945/4.487/2.9935.852343.2169.560.0407851
710*71089.980054/4.0919/2.4536.792666.8216.120.0407856
800*80034.683572/3.767/2.5137.612480.2167.410.0361910
800*80066.786784/3.487/3.4838.282732.7205.330.0362912
800*80010190154/4.3419/2.6139.093004.9243.520.0362916
900*90038.993972/3.997/2.6639.92790.2188.330.0321972
900*9007597584/3.697/3.6940.593074.2226.50.0322974
1000*100043.2104372/4.217/2.8042.083100.3209.260.02891031
1120*112047.3116772/4.4519/1.7844.53464.9234.530.02581096
1120*112091.2121184/4.1219/2.4745.313811.5283.170.02581100
1250*1250102135284/4.3519/2.6147.854253.9316.040.02321165
1250*125052.8130372/4.7019/1.88473867.1261.750.02311163
1120*112091.2121184/4.1219/2.4745.313811.5283.170.02581100

     

   

 

 

 Why you choose us?

  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guaranteed;

 

Hot Products

1kv LV aluminum cable 4x25sqmm cu/pvc/pvc pvc insulated aluminum cable Application: 1kv LV aluminum ...
1kv NYY 4core aluminum cable unarmored 4x35sqmm as per VDE0276, IEC60502-1 Application: 1kv NYY ...
1kv Cu/PVC/PVC/SWA/PVC 3.5C 3x25+1x16sqmm SWA armored power cable VDE0276, IEC60502-1 Application: ...
1kv 3.5C SWA armored copper cable 3x50sqmm power cable VDE0276, IEC60502-1 Application: 1kv NYY ...
1kv 4.5C xlpe insulated copper cable 4x50+1x25sqmm cu/xlpe/pvc as per IEC60502-1 Application: 1kv ...
1kv 4.5C cu/xlpe/pvc 4x95+1x50sqmm LV power cable unarmored as per IEC60502-1 Application: 1kv NYY ...