12.7/22(24)KV 3Cx185sqmm Multi Medium Voltage Power Cables 12/20(24)KV XLPE Insulation cable IEC60502-2

 

​APPLICATIONS:

12.7/22(24)KV 3Cx240sqmm tripolar medinum voltage power cable 12/20(24)KV xlpe insulated power cable are designed for distribution of electrical power with nominal voltage Uo/U ranging from 6.35/11(12)KV and frequency 50Hz. They are suitable for installation mostly in power supply stations, indoors and in cable ducts, outdoors, underground and in water as well as for installation on cable trays for industries, switchboards and power stations.

 

STANDARD:

IEC 60502 Part 2(3.6/6KV to 18/30KV), BS 6622, BS 7835 (LSZH Version)

 

Cable Construction

We adopt highly specialized plant, state-of-the-art research facilities and meticulous quality control procedures that are required for the manufacturing of xlpe insulated cables for use up to 6KV and XLPE insulated cables for use at voltages up to 35 KV. 

 

Conductor

Number of conductors:1,3

The conductors shall comply with the requirement given in IEC

Insulation

XLPE(Cross-linked Polyethylene) according to IEC

Sheath

PVC(Polyaluminium Chloride) according to IEC

Metal screen

Copper Tape Screen

Galvanized tape armoured (SWA/STA)

Sheath colour: Black
Underground cable

 

Product features

XLPE insulated cables
Voltage: Up to 35KV

Conductor temperature

Maximum conductor temperature in normal use: 90℃

Max.short-circuit temperature

Maximum shall not exceed 250℃(5s Max,Duration)

Installation temperature

Ambient temperature under installation shall not be below 0℃

Minimum bending radius

The bending radius of cable: (D-Diameter of cable)

For Three Core Cable————————————-≥15D

For Single Core Cable————————————-≥20D

 

Technical parameters

Three Core 12.7/22KV (Um=24KV) Dimensional Data as per BS 6622/BS 7835 

Nom. Cross- Section

Area

Nom. Insulation Thickness

 

Metallic Tape Screen Area

 

Nom.Bedding Thickness

 

Nom. Armour Wire Diameter

 

Nom. Sheath Thickness

Approx. Overall DiameterApprox. Weight
CUAL
mm²mmmm²mmmmmmmmkg/km
505.5161.52.52.962.377106810
705.5161.62.53.066.587107370
955.5161.72.53.271.2100008130
1205.5161.73.153.377.1120409730
1505.5251.83.153.480.81355010750
1855.5251.93.153.686.31515011610
2405.5252.03.153.792.31771012840
3005.5252.03.153.998.02017014360
4005.5352.23.154.1105.22452016480

 

Three core 12/20kv without armor as per IEC60502-2

Normal cross sectional area(mm²)Appro conductor dia(mm)Nom insulation thickness(mm)Copper tape thickness(mm)Copper wire screen area(mm²)Appro. Insulation dia(mm)Nom sheath thickness(mm)Appro overall diameter(mm)Appro weight(kg/km)
CUAL
mm2mmmmmmmmmmmmmmKg/kmKg/km
357.105.50.11619.71.85338003100
508.255.50.11620.91.85644003500
709.905.50.11622.51.86053004000
9511.75.50.11624.31.86464004600
12013.15.50.11625.72.06774005200
15014.35.50.12526.92.07085005700
18516.35.50.12528.92.175100006500
24018.75.50.12531.32.180122007500
30020.95.50.12533.52.285144008700
40023.75.50.13536.32.3911750010200

 

Products show

 

 

Cable testing 


 

Why Choose Zhenglan Cable:

  • OEM/ODM services provided;
  • Products comply with GB, IEC, BS, ASTM, DIN, VDE and JIS standards; Customer standard requirments Accepted;
  • Certified to ISO 9001:2015, ISO 14001:2015 and OHSAS 18001:2007;
  • Registered capital of $30 million and factory covers an area of 60,000㎡;
  • Advanced test equipment and procedures, 100% inspection before factory;
  • Enough stocks and the higest efficient shipping time guarranteed;
  • Professional pre-sales and after-sales services provided.

FAQ
1. Is your company a factory or a trade company?
Factory, more than 20 years in China

2. How long can I expect to get the sample?
After you pay the freight charge and send us confirmed files, the samples will be ready for delivery in 3-7 days. The samples will be sent to you via express and arrive in 3~7 days. You can use your own express account or prepay us if you do not have an account.

 

3. What are your payment terms?
We normally accept T/T 30% deposit, 70% balance before delivery as the main payment terms, and other payment can also be negotiated. Trade assurance on Alibaba is also available.

4. What’s the delivery time?
Sample order needs 3~5 days. Formal order depends on the quantity. Usually it needs 7-30 days after get your payment.

 

5. What is your MOQ?
Generally for medinum voltage poer cable MOQ is 1000m.

 

Hot Products

1kv PVC insulated copper cable 4x50mm2 low voltage power cable Application: 1kv PVC insulated copper ...
1kv XLPE insulated power cable N2XY 4x16mm2 Cu/XLPE/PVC IEC60502-1 Application: 1kv XLPE insulated ...
1kv Cu/xlpe/lszh N2XH 4x35+1x16mm2 power cable LV power cable Application: 1kv Cu/xlpe/lszh N2XH ...
12/20(24)kV 12.7/22(24)kV Three Cores Al/Cu conductor XLPE/PVC insulated LZSH jacket Armoured Power ...
3x150mm2 aluminium/copper conductor STA armored PVC sheath cable MV Underground Cable BS 6622/BS ...
8.7/15kV Medium Voltage 3X185mm2 Copper Or Aluminum Conductor XLPE insulated PVC jacekt Power Cables ...