High Precision Radar Water Level Sensor Price Transmitter Water Level Transmitter

 

Sensor is 26G High Frequency radar level sensor, measure the maximum distance to 70 meters.

Antenna being further optimized, fast new microprocessor could be higher-speed signals processing, makes the instrument can be used in reactors, solid-state storage bin and some complicated
measuring conditions.
Antenna size is small, easy to install; non-contact radar, no abrasion, no pollution. Which is almost not influenced by corrosion and foam. And virtually unaffected by water vapor, temperature and pressure changes in the atmosphere. Serious dust environment has little effect on high frequency level meter. Shorter wavelength, and has a better reflection on inclined solid surface. Beam angle, energy concentration, while enhanced echo and to avoid the interference. Measure blind spots smaller
canisters measure will achieve good results. The low noise ratio, even in case of fluctuations can get
better performance. High frequency is the best choice for measuring solids and low dielectric constant.

 

How does radar level measurement work?

 

The device operates according to the FMCW method (FMCW = Frequency Modulated Continuous Wave). Electromagnetic pulses in the GHz range are sent to the medium at different frequencies between 77 and 81 GHz. Since the transmitter is constantly changing the frequency of the transmitted signal, there is a frequency difference between the transmitted and reflected signals. Subtract the frequency of the reflected signal from the frequency of the transmitted signal at that time to obtain a low-frequency signal proportional to the horizontal distance. This signal is further processed to enable fast, reliable and highly accurate level measurement

 

Speifications

 

Technical Specifications
Housing:
Steel 316L
 
Seal ring between housing and housing cover
Silicone
view Point window on housing
Polycarbonate
Ground terminal
Stainless Steel
Power:
Two-wirc
standard version
(16~36) VDC
Intrinsic safe version
(21.6~26.4) VDC
Power consumption
max.22.5mA
Ripple allowed
 
—<100Hz
Uss<1V
—(<100~<100K)Hz
Uss<10mV
Four-wire/two
intrinsic safe+explosion proof
(21.6一26.4) VDC,
-chamber
Power consumption
max.1VA,1W
Cable:
Cable entry/plug
one cable entry of M20x1.5,one blind of M20x1.5
Spring Connection terminal
Application for cables with cross section of2.5m㎡
Output:
Output signal
4~-20mA/HART
Resolution
1.6 μa
Fault signal
Constant current output:20.5mA; 22mA; 3.9mA
Integration time
0~50 seconds,adjustable
Blind spot
end of antenna
Max. measurement distance
10m
Microwave frequency
26GHz
Measurement interval
about 1 sec.(depend on parameter settings)
Adjustment time
about 1 sec.(depend on parameter settings)
Resolution on display
1mm
Accuracy
see the diagram below
Temperature for storage/transport
(-40~80)℃
Process tempcrature (probe)
(-40~250)℃
Relative humidity
<95%
Pressure
Max.4MPa
Vibration proof
mechanical vibration l0m/s3 ,(10~~150)Hz

 

Applications

 

● City water supply

● Sewage treatment

● Tank level monitoringT

● Water-saving irrigation

● Circulation fluid monitoring

 

 

Hot Products

Feature ● 0~40 bar ● Absolute, gauge and sealed gauge ● ±0.5% static accuracy ● 0.5~4.5Vdc...
Speifications pressure medium gas liquid compatible stainless steel pressure ranges 0~2...1000bar ...
Feature ● MEMS technology ● Imported silicon sensor chip employed ● Perfect long term stability ● CE ...
Applications ● Industrial process control ● Energy and water treatment ● Liquid pressure system and ...
Applications ● Industrial process control ● Energy and water treatment ● Liquid pressure system and ...
Description PT201-3 series of pressure transmitter is a standard and most popular transmitter ...