Home Companies Shenzhen Qianhai Lensen Technology Co., Ltd

Advantech Wireless I O Module 4 Channels Wireless Modbus RTU 4-20mA Wireless Signal Transfer

Shenzhen Qianhai Lensen Technology Co., Ltd

Contact Us

[China] country

Trade Verify

Address: 701, Yongchang Building, Xicheng Industrial Zone, Xixiang, Bao'an District, Shenzhen, China 518126

Contact name:Sunny

Inquir Now

Shenzhen Qianhai Lensen Technology Co., Ltd

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Advantech Wireless I O Module 4 Channels Wireless Modbus RTU 4-20mA Wireless Signal Transfer

Country/Region china
City & Province shenzhen guangdong
InquireNow

Product Details

LS-RAO04 wireless analog acquisition module

 

LS-RAO04 Modbus RTU is a 1W I/O module, 4 analog outputs, 1 RS485 (wireless RS485 customizes). Wireless control 2km-3km. Use for sensor and PLC/HMI wireless communication.

  • Transparent I/O System
  • Not need internet, no third party cell, no monthly fees
  • You have full control over your own carrier
  • Real time status feedback from the remote site
  • Fast installation and easy setup

 

Frequency433MHz or 450MHz or 470MHz
Power output1W
Products4AO
Input type4-20mA or 0-5V or 0-10V
Output type4-20mA or 0-5V or 0-10V
Resolution ratio24 bit
Accuracy±0.02%
Power supply9-36V DC usually use 24V DC
InterfaceRS-485
Channel No.15ch default, can program via DIP switch
AntennaSucker antenna with 1.5m cable
Working temperature-35 °C~+75 °C industrial
Working humidity10%-90% relative humidity, no condensation
Dimension115×90×40(mm)
Fix wayStandard 3.5 inch industrial DIN guild rail

 

Advantage of wireless solution

- No wires to bury or maintain, no need to drill holes on wall

- Reliable communication in all direction,any terrain, regardless of hills, walls, trees

- Cost saving in installation and maintenance

- Radio/Lora based, no need internet and monthly fee, full ownership of the system

- 4G based, high speed, no distance limit

 

Lensen Wireless RTU features

- Portable device, DIN-rail mounting for easy installation

- Isolated inputs

- LEDs for power supply, communication, input, output status

- Flexible networking, point to point or point to multipoints

- DIP to change different modes

- Different types of I/O, DI, DO, AI, AO are available

- I/O expandable

- Short delay time

- Easy handing on RS485 network, support Modbus RTU protocol

- Support on-line upgrade. Can configure by customer in setting mode

 

 

Modbus RTU communication and corresponding value

Register types:

Register typesRead command

Write command

(Control command)

Power offFunction
Hold register0x01

Input --not support

Output--support

Not keepCan read input value
0x03

 

A. Hold register

1. Analog input value: 0x0008~0x000B

2. Analog output value: 0x0048~0x004B

 

B: How to read

Hold register: can read 4 analog input or control 4 analog output at one time

 

Register control way

 

AI/AOIC

Read/

write

Function IDitems support
No.IC TypePLC IDModbus ID
AI1Hold register400098Read032AI/4AI
AI2Hold register400109Read03
AI3Hold register4001110Read034AI
AI4Hold register4001211Read03
AO1Hold register4007372Read/write03/062AO/4AO
AO2Hold register4007473Read/write03/06
AO3Hold register4007574Read/write03/064AO
AO4Hold register4007675Read/write03/06
 

 

About value calculation

Analog input

Our analog module’s max measure range value is : 0X7FFF

1. Directly measure current and voltage

Exact value=value you read/0x7FFF*max range

For example: to read the 1st passage of module’s (with max range of 0-20mA) input value

Register 0x0008(analog input of the 1st passage)

Feedback: 0x3801

Current value: (0x3801/0x7FFF)*20mA=8.7509mA

 

2. To measure sensor’s value(4-20mA, 0-6 meter level sensor)

If feedback value is less than 6554, level value is 0

If feedback value is bigger than 6554, level value=(value read-6554)/(32767-6554)*measure ranges

For example: feedback value is 0X3801, then corresponding level value is: ((0X3801-6554)/26213)*6 meter=1.7815 meter

 

Analog output

Analog module’s max measure range is: 0x7FFF

Directly control output current and voltage

Write register value=current or voltage value/measure range*0x7FFF

For example: to control the 1st passage of analog module whose max measure range is 0-20mA

Register 0x0048 (analog output of the 1st passage)

To write register value:(8.75/20mA)*0X7FFF =14336=0x3800

 

 

Hot Products

LS-S100 is a very small size RF transceiver. It is usually used for restricted space application. ...
Mini RF Data Module Low Power Wireless Transceiver TTL Port 9600bps LS-S100 is a Mini-size RF data ...
RS485 Wireless Radio Modem 1W Wireless DTU RS485 Radio Moddem PLC wireless module RS232 RS485 USB ...
433MHz Radio Modem Serial Data Wireless Transmitter 2km RS232 Introduction: This is a UHF band 1W ...
5W 24V Power Supply Wireless RS485 Module PLC Wireless Communication Radio 1. General Introduction ...
1W RS232 RS485 Wireless Radio Modem Modbus DTU PLC Communication 1W Wireless Radio Modem 1W RS232 ...