Single-weighing-hopper/bag Ration Packing Controller for Filling Machine Powder Packing Machine

 

Main Features​:

Suitable for Loss-in-weight Ration Packing Scale with Auto Bag-releasing or Manual Bag-releasing and Loss-in-weight Bulk Material Ration Feeding Scale.

 

Technical Specification

¨ Display

² 6+8 Red LED digital tubes for English character and digit display.

² Weight Display Range: -99,999~+999,999.

² Scale Capacity: Setting Range 1~999,999.

² Scale Division: Optional 1, 2, 5, 10, 20, 50, 100, 200, 500.

² Display Resolution: 1/100,000.

² Weight Unit: Optional kg, t, g, none.

² Decimal Point: Optional 0, 0.0, 0.00, 0.000, 0.0000.

² Display Refreshing Time: Setting Range 0.01~1.00s.

¨ Kaypad

² Model Panel-mounting: 4-key English keypad.

² Model Explosion-proof: 6-key English keypad.

² Menu&Shortcut mode operation with key tone.

¨ Loadcell Interface

² Excitation Voltage/Max. Current: DC9V/120mA [4-350Ω loadcells].

² Signal Input Range: 0~22.5mV.

² Output Sensitivity of Loadcell: 1.0~2.5mV/V.

² 24-bit ∑-ADC with internal resolution 1/1,000,000.

² Sampling Frequency: 400Hz.

² Special anti-vibration digital filtering algorithm.

² Zero Drift: ±0.1μV/ RTI (Relative to Input).

² Gain Drift: ±5ppm/.

² Non-linearity: 0.005%FS.

¨ Switch&Analog Signal Interface

² 6 Normally Open Switch Inputs [DI].

² 8 Normally Open Transistor Switch Outputs [DO]: DC24V, 250mA.

² 1 Optional&Definable Analog Signal Output [AO]: 4~20mA, Non-linearity: 0.05%FS.

¨ Digital Communication Interface

² COM1: RS232.

² COM2: RS485.

² Connectable: Host IPC/PLC and LED Remote Display.

¨ Operating Specification

² Operating Voltage

l Model Panel-mounting: DC24V±20%.

l Model Explosion-proof: AC110~240V, 50/60Hz.

² Max. Power Consumption: 5W.

² Outline Size

l Model Panel-mounting: 110×62×150mm [W×H×D].

l Model Explosion-proof: 256×290×166mm [W×H×D].

² Panel Cut-out Size

l Model Panel-mounting: 94×47 mm [W×H].

² Operating Temperature: -25℃ to +45℃.

² Storage Temperature: -30℃ to +60℃.

² Relative Humidity: Max. 85%RH.

² Application Environment of Model Explosion-proof

l Explosion gas environment: Zone 1&2.

l Classes of explosion gas mixture: IIA, IIB.

l Temperature grades of explosion gas mixture: T1~T6.

l Ex-mark: Ex d IIB T6 Gb.

² Protection Level

l Front Panel of Model Panel-mounting: IP65.

l Model Explosion-proof: IP65.

² Weight

l Model Panel-mounting: Approx. 0.5kg.

l Model Explosion-proof: Approx. 9.2kg.

 

Technical Specification:

Display6+8 Red LED digital tubes for English character and digit display
Weight Display Range-99,999~+999,999
Scale CapacitySetting Range 1~999,999
Scale DivisionOptional 1, 2, 5, 10, 20, 50, 100, 200, 500
Display Resolution1/100,000
Weight UnitOptional kg, t, g, none
Loadcell InterfaceExcitation Voltage/Max. CurrentDC9V/120mA [4-350Ω loadcells]
Signal Input Range0~22.5mV
Output Sensitivity of Loadcell1.0~2.5mV/V
Sampling Frequency400Hz
Non-linearity0.005%FS
Switch&Analog Signal InterfaceDI6 Normally Open Switch Inputs
DO8 Normally Open Transistor Switch Outputs [DO]: DC24V, 250mA
AO1 AO:4~20mA
Digital Communication InterfaceCOM1RS232
COM2RS485
ConnectableHost IPC/PLC and LED Remote Display

 

 

System Diagram for APP1 Ration Packing Mode

 

System Diagram for APP2 Bulk Material Ration Feeding Mode

 

Keypad Operation

Menu Operation
Key NameDescription
【MENU】

Enter Main Menu.

Exit.

【ENT】Enter / Save / Clear Alarm.
【◄】

Cursor shifts left.

Display the previous option.

【►】

Cursor shifts left.

Display the next option.

【▲】

Display the next interface or option.

Digit input: +1 ( 0~9 loop).

【▼】

Display the previous interface or option.

Digit input: -1 ( 0~9 loop).

Quick Operation

【MENU】

【Ñ】

*

  • Key-locking.
  • Key-unlocking.

【◄】

(【SET】)

Recipe parameters setting.

【◄】

【ZERO】

【→0←】

*

  • [-ZEro-]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
  • [≡ZEro≡]: Manual Zero without Power-down Protection and without Clearing Tare Weight.
  • The controller will switch to Gross Weight display.

【▲】

【TARE】

【→T←】

*

  • [≡tArE≡]: Manual Tare without Power-down Protection.
  • [-PStr-]: Preset Tare Weight with Power-down Protection.
  • [-rStr-]: Clear Tare Weight with Power-down Protection.
  • The controller will switch to Net Weight display.

【ENT】

【G/N】

Gross Weight / Net Weight display switch.

 

 

 

Hot Products

Medicine Bottle Filling Machine Indicator, Liquid Filling Weighing Controller CE Certified Suitable ...
Liquid and Powder Filling Machine Controller, Petroleum/Oil Filling Indicator for Filling System ...
BST106-C11+ is panel mounted indicator for hopper weighing, axle weighing and so on. Specification: ...
Multi-function weighing indicator for hopper weighing, platform weighing, batching weighing ...
Weighing Force Measuring Weighing Control Module With 0~20mA And 0~10V AO Product Description ...
Mini Conveyor Scale Weighing Module With Low Price But High Quality Specification: Application ...