Single-Scale HMI Ration Batching Weighing Controller for Concrete Batching Machine Four Bins Aggregate Batcher Hopper

 

 

Technical Specifications

  • Power Supply: DC24V±20%, Max. 10W.
  • Loadcell Excitation Voltage/Current: DC5V/250mA.
  • 16 Loadcells[350Ω] connectable.
  • Weighing Signal Input Range: 0~12.5mV
  • Digital Communication Interface
  • COM1[RS232]&COM2[RS485] for connecting Host IPC/PLC and LED Remote Display.
  • COM[RS232] for connecting RS232 Serial Printer with Baud Rate ‘9600bps’, Parity Check ‘None’, 8 Data Bits and 1 Stop Bit.
  • USB1 for connecting USB mouse, downloading HMI software from U-disk and copying data to U-disk.
  • LAN: Optional Ethernet port.
  • Outline Size [W×H×D]
  • 7”: 226.5 × 163 × 36 mm.
  • 10.2”: 274 × 193 × 40 mm.
  • Panel Cut-out Size [W×H]
  • 7”: 215 × 152 mm.
  • 10.2”: 261 × 180 mm.

Button Operation

 

NameOperationState IndicatorAuthorization
【Auto】Auto / Manual [Emergency Stop] switch.

Green: Auto state.

Grey: Manual state.

All Users
【Start】Start.

Green: Running state.

Grey: Stop state.

【Re-run】Clear Alarm & Recover Running. 
【Stop】

Normal Stop [Last Batch].

Stop after the present batch finished.

Flashing Red.
【Pause】Pause. 
【E-stop】Emergency Stop. 
【Alarm】

Alarm Query / Clear Alarm.

‘Auto/Pause’ state: Recover Running after alarms cleared.

Red: Alarm state.
【Shift】

Batching Hoppers/Materials Shift.

Mixer in Weighing Hopper Run Selection While Bulk Feeding.

Recipe Display Style in Main User Interfaces.

Green/Blue: Selected.

Grey: Unselected.

【Print】

Report Print:

  • [ Auto Print]: Print Batch Records.
  • [Total]: Print Totalizing Report.
  • [Recipe]: Print Working Recipe.
 
【Lock】

Screen-locking: Locking/unlocking the operating buttons of main user interface.

Auto Screen-locking: Refer to parameter [901].

Flashing Red: Locked.

Grey: Unlocked.

【Menu】Enter Main Menu. 
【User】User Login. Display: Operator / Engineer / Admin. 
【Zero】Manual Zero [No Power-down Protection].Flashing green.
【Bulk】Manual Start/Stop Mn Bulk Feed.Green: Working state.
【Drip】Manual Start/Stop Mn Dribble Feed.Green: Working state.
【Dump】Manual Start/Stop Dumping.Green: Working state.
【Mn】Material Selection for Manual Operation. 
【MixTank Dump】Manual Start/Stop Mixing Tank Dumping.  
【Clear】Clear Screen: Clear the display values of Feeding Weight, Totalized Weight and Batch Count’. 

Engineer

Administrator

Main User Interfaces

Hot Products

Belt Weigher Indicator Loss-in-weight Weighfeeder Controller for Conveyor Scale Suitable for Ration ...
Belt Feeder Scale with Weight Totalizing & High Anti-jam for Industrial Environment BST100-E21 ...
Touch Screen Liquid Filling Machine Indicator, Suitable for Liquid/Gas/Powder Ration Filling Scales ...
Sorting Check Weighing Indicator, Controller For Automatic Flipper Type Checkweigher Scales ...
Four Scales Packaging Weight Scale Controller, Weight Indicator For Industrial Weighing Systems ...
Product Description: Weighing controller BST100-E11 is a panel mounted one, with high accuracy 0.5%...