Home Companies CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID

Zero Tracking Weighing Indicator Load Cell Display And Controller Dc24v With AO DO RS485 RS232

CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID
Active Member

Contact Us

[China] country

Address: BUILDING A6, LUGU INTERNATIONAL INDUSTRIAL PARK,CHANGSHA, 410006, CHINA

Contact name:Lisa

Inquir Now

CHANGSHA SUPMETER TECHNOLOGICAL CO.,LID

Zero Tracking Weighing Indicator Load Cell Display And Controller Dc24v With AO DO RS485 RS232

Country/Region china
City & Province changsha hunan
Categories Advertising Screens
InquireNow

Product Details

Zero Tracking Weighing Indicator Load Cell Display And Controller Dc24v With AO DO RS485 RS232

 

Technical Specifications
 Power Supply: DC24V±20%, Max. 5W.
 Loadcell Excitation Voltage/Current: DC5V/120mA.
 8 Loadcells[350Ω] connectable.
 Transmitter Excitation Voltage/Current: DC12V/100mA.
 Optional weighing input signal mV, V and mA.
 【mV】Signal Input Range: 0~19.5mV.
 【V】Signal Input Range: 0~2.5V, 0~5V, 0~10V.
 【mA】Signal Input Range: 0~20mA.
 2 Normally open/closed Relays [DO]: AC250V/DC24V, 1A.
 1 Analog Signal Output [AO]: 0~20mA, 0.05%FS.
 COM1: RS232.
 COM2: RS485.

 

Technical Specifiction:

Power SupplyAC24V±20%
Display5 Red Led Digital Tubes for English&Digit Display
Sampling Frequency1280Hz
A/D Convert24-bit
Keypad4 keys for Shortcut mode operation with key tone
Excitation Voltage Output of LoadcellDC5V
Max. Connection number of Loadcell8 Loadcells (350Ω)
[mV]Signal Input Range0-19.5mV
DO2 Normally Open Transistor Switch Outputs
AO1Analog Signal Output: 4~20mA.
Communication PortCOM1:RS232;COM2:RS485
Outline Dimension107 × 60 × 100 mm (W×H×D)
Net WeightApprox. 1.2kg
IP GradeIP65
Verfication Accuracy0.03%
Static Weighing/Force Measuring Accuracy0.2%~.5~

 

Keypad Operation

Menu Operation
Key NameDescription
【■】Enter Main Menu / Exit.
8Enter / Save / Clear Alarm.
【►】

Cursor shifts right.

Display the previous option.

【▲】

Display the next interface or option.

Digit input: +1 ( 0~9 loop).

 

Quick Operation Mode A

Parameter [904]= ‘0. dE’ [Default Set]

Key NameDescription
【■】*
  • Key-locking.
  • Key-unlocking.

【►】

(【SET】)

Setpoint parameters setting.

【►】*

(【ZERO】)

(【→0←】)

  • [-ZEro]: Zero Calibration with Power-down Protection and Clearing Tare Weight.
  • [≡ZEro]: Manual Zero without Power-down Protection and without Clearing Tare Weight.
  • The controller will switch to Gross Weight display.

【▲】*

(【TARE】)

(【→T←】)

  • [≡tArE]: Manual Tare without Power-down Protection.
  • [-PStr]: Preset Tare Weight with Power-down Protection.
  • [-rStr]: Clear Tare Weight with Power-down Protection.
  • The controller will switch to Net Weight display.

8

(【G/N】)

Gross Weight / Net Weight / Net Weight Peak Value display switch.

8】*

(【CLS】)

  • [-CLS] : Clear Screen [Clear the display value of Peak Hold Value].

 

Model Panel-mounting Operation Interface

 

Load Calibration (LoAd)

After doing Data Calibration, if there are conditions for Load Caliration, do Load Calibration with
loading standard weight on the weigher to correct Span Coefficient further for higher weighing accuracy.
The loading weight should be bigger than 50% of Scale Capacity value.

 

Main Display Interface

Hot Products

TFT-Touch Ration Filling Controller, Liquid Filling Machine Controller/Indicator Main Features: 1. ...
Belt Weigher Indicator Loss-in-weight Weighfeeder Controller for Conveyor Scale Suitable for Ration ...
Belt Feeder Scale with Weight Totalizing & High Anti-jam for Industrial Environment BST100-E21 ...
Touch Screen Liquid Filling Machine Indicator, Suitable for Liquid/Gas/Powder Ration Filling Scales ...
Sorting Check Weighing Indicator, Controller For Automatic Flipper Type Checkweigher Scales ...
Four Scales Packaging Weight Scale Controller, Weight Indicator For Industrial Weighing Systems ...