Anhui Wanyi Science and Technology Co., Ltd. |
Verified Suppliers
|
|
Wayeal Flame Atomic Absorption Spectroscopy AAS Atomic Absorption
Spectrophotometer Machine for Metal Analysis
Product Introduction
Atomic absorption spectrophotometry analyzes the concentration of
elements in a liquid sample based on energy absorbed from certain
wavelengths of light (usually 190 to 900 nm). Atomic absorption
spectrophotometers typically include a flame burner to atomize the
sample (most commonly a hollow cathode lamp), a monochromator and a
photon detector. Depending on the model, some atomic absorption
spectrometers are equipped with a turret or fixed lamp socket that
can hold multiple lamps (up to eight) to reduce downtime between
samples or allow for sequential analysis.
Product Parameter
Wayeal AA2230 Graphite Furnace AAS Atomic Absorption Spectroscopy Machine Atomic Absorption Spectrophotometer | |
Models | AA2250 |
Wavelength Range(nm) | 185-910 |
Wavelength Indication Error(mm) | ±0.15 |
Wavelength Repeatability(nm) | ≤0.05 |
Broadband Deviation(nm) | ±0.01 |
Resolution(%) | ≤15 |
Instantaneous Noise(Abs) | ±0.0015 |
Zero Drift(Abs/30min) | ±0.001 |
Boundary Energy:Instantaneous Noise(Abs) | ≤0.01 |
Detection Limit(Flame:Cu ug/mL)) | ≤0.002 |
Apparent Atomization rate(%) | ≥12 |
Detection Limit(Graphite Furnance: Cd pg) | ≤0.2 |
Repeatability(Flame RSD%) | ≤0.1 |
Repeatability(Graphite Furnance RSD%) | ≤0.85 |
Linearity Error(%) | ≤2 |
Background Correction Capability | ≥75 |
Product Features
1. Stability: Double-beam system can automatically compensate the
light source drift and wavelength drift caused by the variation of
temperature (with the function of the eliminating the affection of
wavelength drift on the base line stability) and electronic circuit
drift so as to reach a good basic line stability.
2. Full-reflection dual-beam optical path, high optical path
stability
3. High precision of measurement: Gas path system is equipped with
precision pressure stabilizing and current stabilizing devices to
reach stable flame and low noise. Specially designed fine light
beam passes through the flame to ensure a high precision analytical
test and low characteristic concentration.
4. 6 lamp holders preheat simultaneously to improve detection
efficiency
Product Application
Foods and Beverages – In synthetic processed foods, metal pickup takes place due to contact with processing equipment and catalytic conversions. Consumer awareness on food safety is increasing by the day so manufacturers have to ensure that the trace metals do not exceed the permissible limits and this requires rigorous quality control through atomic absorption spectroscopy and other sophisticated instruments.
Oil and Petroleum – Both edible oils and mineral oils require refining before consumption. Such refining operation can involve distillation as well as catalytic refining. Uptake of metals during such operations can lead to deterioration of performance or consumer hazards. Trace metal analysis of engine oil provides useful diagnostic information on the wear and tear of engine parts.
Agriculture – Trace metal constitution of soils in addition to their acidic or basic nature is essential to establish their productivity and nutrient value. Trace metal composition of plants (leaves, stems and roots) gives a fair idea on how the uptake of minerals gets distributed under different growth conditions
Forensics – Trace metal analysis provides valuable information on specimens such as stomach contents for food poisoning, paint chips, fibres and hair strands collected from the scene of a crime