Home Companies Foshan Shunde Dongyuan Gas Appliances Industrial Co., Ltd.

Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display

Foshan Shunde Dongyuan Gas Appliances Industrial Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: No.3 Depin Road, Xingtan,Shunde,Foshan,Guangdong,China

Contact name:

Inquir Now

Foshan Shunde Dongyuan Gas Appliances Industrial Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Hot Water Gas Central Heating Boilers , House Boiler System With LCD Display

Country/Region china
City & Province foshan guangdong
InquireNow

Product Details

Gas Central Heating LCD Display For Room Heating And Sanitary Hot Water Home Gas Boiler

 

Technical data

 

Model NumberL1PB24L1PB32
Gas TypeNG/LPG
Rated Gas Pressure(Pa)2000/2800
Rated Gas Input(kw)2432
Rated Gas Output(kw)21.128.2
Efficiency Under Rated Heat Input(%)Above88%
Power Supply20-50HZ
Electric Power(W)110145
Temp.Range Of Heating Water(℃)Radiator:30-80 Floor Heating:30-60
Heating Area(㎡)100-200200-300
Lift Of pump(m)57
Application Water Pressure(Mpa)0.1-0.3
Expansion Tank Capacity(L)68
Preset Pressure Of Expansion Vessel(Mpa)0.1
Water Circulation TypeAirtight Forced Circulation
△T=25℃ Hot Water Supply(kg/min)1216
△T=30℃ Hot Water Supply(kg/min)1013.3
Temp.Range Of DHW Supply(℃)30-60
Applicative Water Pressure(mpa)0.03-0.8
The Minimum Starting Flow (L/min)2
The Minimum Closed Flow(L/min)1.6
Connections(mm)For Gas&Heating Water Pipes:G3/4 For DHW Pipes:G1/2
Air Input/Exhaust Duct(mm)φ60/φ100
Sparated Input/Exhaust Duct(optional)φ80/φ100
The length Of Flue Dust(m)1
Noise On Working(DB)<42
Exhaust TypeForced Exhaust
Ignition TypeIntegrated Automatic Ignition
Temperature ControlGas Proportional Adjustment
Product Dimensions(mm)740*400*305855*470*390
Packing Dimensions(mm)865*470*385870*495*390
Container(20GP/40GP/40HQ)17//357/434166/333/404

 

 

- With control circuit boards,control centers for high- intelligent  equipment opeartion and safety protection.

- With multi-stage intelligent antifreeze,multi-stage combustion,  the temperature is less than 8 degrees celsius 

to start automatically, the pump after sycle in th burning to stop working, the pump.

- Delay opeartion to prevent overheating repeatedly.

- With LED- all round electronic display.

- The original modular design, assembly and disassembly is simple, fault memory function, convenient for the

rapid diagnosis of after sales personnel.

- The invention patent high-frequency electronic anti scalling device and the original windbreak and sand 

structure design are committed to manufacturing gas wall hanging stove products suitable for our conditions.

- Dynamic fire display, automatic central control data output, intuitive and convenient.

 

- Touch buttons, big-screen dynamic LCD display, sensitive and comfortable.

- Digital precise temperature control system, are free to adjust temperature.

- Green environmental protection,ultra-low emission.

- Fan burner with full gas- air premix provides gas combustion with close to ideal conditions-so the condensation 

process begin earlier and by higher return line temperature(about 57℃)

- Electronic controlled fan with variable rotation speed for keeping the optimal minimal required air exceed in the

gas-air mix.

- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant, with 

great optimization of gas consumption.

- Indication of temperatures, working modes, current burner power and error codes on the color multifunctional 

LCD display.

 

 

- PCB is insensitive to the electric polarity and fluctuations of voltage AC 160-242 Volt.

- Integrated 24-hour/week timer sets normal or lower heating temperature within each day of week with the benefits 

of comfort and low gas consumption.

- Automatic electronic ignition and ionization flame control.

- Can connect with room thermostat and remote controller which can provide more function options.

- Working mode and error codes indication by 1 light- emitting diodes(LCD) on the control panel.

- Modulation: boiler output changes automatically to keep the set heating and DHW temperature constant, with great 

optimization of gas consumption.

- Frost protection: burner and pump will be switch on automatically by danger of freezing, It is allowed to use antifreeze 

liquid instead of water in the heating system.

- Supports outdoor temperature driven mode.

 

 

 

 

 

 

 

 

Hot Products

Wall Hung Gas Boiler For Home Heating Gas Central heating Environmental Protection For Heating And ...
Wall Hung Gas Boiler For Home Heating Gas Central heating Environmental Protection For Heating And ...
Gas Central heating Environmental Protection For Heating And Domestic Hot Water Gas Boiler Technical ...
Wall Hung Gas Boiler For Home Heating Gas Central heating Environmental Protection For Heating And ...
Heating and hot water wall hung gas boiler for home heating area 100-200㎡ Model Number L1PB24 Rated ...
High flow hot water central supply system wall hung gas boiler with temperature controller 24H ...