2 3 4 Pole Measurement Digital Earth Resistance Tester With Amicrocomputer

 

VICTOR 4108 Multifunctional Earth Resistance Earth Resistivity Tester Equipped With Amicrocomputer 2 Pole 3 Pole 4 Pole Measurement

 

Generalization

This Instrument is a multifunctional earth resistance/earth resistivity tester equipped with a microcomputer.

This Instrument employs DSP processor and digital signal processing technology, which draws earth measurement signals directly, possesses features of high frequency, high accuracy and high resistance, and can measure earth resistance accurately.

The Instrument can measure earth ambient parameters (interference frequency and interference voltage), analyze earth measurement noise, and then select a measurement frequency which can reduce the noisy impacts maximally.

Apart from execution of standard 3-POLE and 4-POLE earth resistance measurements, this Instrument provides a method which can measure earth electrode resistance of a single –point and reticular earth resistance system without cutting off any earth electrode in parallel. This Instrument processes functions of earth resistivity calculation, no-spike earth resistance measurement, equipotential resistance measurement and current measurement with clamps.

l The Instrument conforms to the following Safety Requirements:

IEC61010-1(CAT Ⅲ 600V, POLUTION degreeⅡ)

IEC61010-2-031(Special Requirements for hand-held Probes)

IEC61010-2-032(Special Requirements for hand-held Current Clamp)

IEC61557-1,4,5,10(Electronic safety requirements for low voltage distribution system below AC 1000v and DC 1500v )

 

Basic Measurement Function

2/3/4- pole earth resistance measurement

Selective Earth Resistance Measurement

No-spike Earth Resistance Measurement

Earth resistivity (ρ)Measurement

Equipotential resistance measurement (2-pole/ 4-pole current measurement)

 

AC Current Measurement(1mA~20A)

l Earth Resistance Measurement employs sine AC simulation measurement, 4 kinds of testing frequencies(94Hz, 105Hz, 111Hz, 128Hz),which are selectable by hand or automatically to reduce impacts from low interference sources.

l Automatic control function of measurement signal frequency(AFC).

l Auxiliary Earth Resistance Measurement Function.

 

Measurement and display of Auxiliary Earth Resistance

l Up-limit warning display function of auxiliary earth resistance

Warnings are displayed on the LCD when auxiliary earth resistances are too high and may result in inaccurate measurements.

l Equipotential earth resistance measurement , processing automatic polarity-reverse measurement function

l Auto-range Function in Resistance Measurement and OL displays for over range

l Smoothing Measurement

In serious interference cases, the stability of measurement results can be improved by smoothing

Indication Functions for high interference voltage and current.

 

l Measurement Function of interference voltage and frequency in series.

Can automatically judge AV, DC and display voltage value and frequency when interference voltage in series exits

l Indication Function for over-low measurement current of current clamp

l Dot-matrix 240×128, Monochrome LCD.

l Backlight Function to view the test results in dimly areas.

l OH Indication Function.

l Rk Function is available to cancel the residual resistance on the Test Leads.

l Pre-programmed limits, pass or fail evaluation of measurement results

 

Standard accessories

• Measurement Suit:H000007

includes:

1 testing wire 6m(black)

1 testing wire 6m(green)

1 testing wire 15m(red)

1 testing wire 30m(blue)

4 auxiliary earth spikes

• 1 user’s manual

• 8 1.5V (LR6)Alkaline batteries

• USB Communication wire

• a software disk(ERTMA)

• Low Range Clamp: H300000R

• Standard Range Clamp: H300000T

• Measurement Ring:H900000

Chosen accessories

• DC15V adaptor

• Rechargeable Batteries(8☓1.2V Ni-Hi or Ni-chromium rechargeable batteries LR6)

 

Basic index

Disturbance voltage(UST)

Measuring rangeResolutionFrequency rangePrecision
0.0V~50.0V0.1V

DC /AC

45~400Hz Sine

5%+5

 

Interference frequency(FST)

Measuring rangeResolutionVoltage rangePrecision
16~400Hz0.1Hz1V~50V1%+5

 

Current measurement(IST)

Measuring rangeResolutionFrequency rangePrecision
1.0mA~25.0mA0.1mA50 / 60Hz5%+5
25mA~250mA1mA
0.25A~2.50A0.01A
2.5A~20.0A0. 1A

 

Grounding resistance RE (testρ)

rangeMeasuring rangeResolutionPrecision
0.020Ω~1.999Ω0.001Ω2%+0.03Ω
20Ω2.00Ω~19.99Ω0.01Ω2%+5
200Ω20.0Ω~199.9Ω0.1Ω
2000Ω200Ω~1999Ω
20kΩ2.00KΩ~19.99kΩ0.01kΩ
200kΩ20.0KΩ~199.9kΩ0.1kΩ

 

Selective grounding resistance(RE )

rangeMeasuring rangeResolutionPrecision
0.020Ω~1.999Ω0.001Ω5%+0.03Ω
20Ω2.00Ω~19.99Ω0.01Ω5%+5
200Ω20.0Ω~199.9Ω0.1Ω
2000Ω200Ω~1999Ω
20kΩ2.00KΩ~19.99kΩ0.01kΩ

 

Without the wand grounding resistance measurement( )

rangeMeasuring rangeResolutionPrecision
0.02Ω~1.99Ω0.01Ω10%+6
20Ω2.0Ω~19.9Ω0.1Ω10%+2
100Ω20Ω~100Ω20%

 

Measurement of soil resistivity (ρ)

rangeMeasuring rangeResolutionPrecision
20Ω·m0Ω·m~19.99Ω·m0.01Ω·m

Depend on RG

ρ=2×π×a×RG

 

Note: electrodes a :0 ~ 30 m

200Ω·m20.0Ω·m~199.9Ω·m0.1Ω·m
2000Ω·m200Ω·m~1999Ω·m1Ω·m
20kΩ·m2.00kΩ·m~19.99kΩ·m0.01kΩ·m
200kΩ·m20.0kΩ·m~199.9kΩ·m0.1kΩ·m
2000kΩ·m200kΩ·m~3768kΩ·m1kΩ·m

DC resistance (R )measurement

rangeMeasuring rangeResolutionPrecision
0.020Ω~1.999Ω0.001Ω2%+2
20Ω2.00Ω~19.99Ω0.01Ω
200Ω20.0Ω~199.9Ω0.1Ω
2000Ω200Ω~1999Ω
20KΩ2.00KΩ~19.99KΩ0.01KΩ
200KΩ20.0KΩ~199.9KΩ0.1KΩ

 

More details 

ProjectVICTOR 4108
Measuring function
 
Measurement of RE pile method2pole
3pole
4pole
Measurement of RE selective electrode method3 pole + single clamp
4 pole + single clamp
Double clamp
method
Soil resistivity
Equipotential resistance measurement
Interference
measurement
Disturbance voltage(AC,DC)
Interference frequency
Clamp current measurement
The test frequency(Hz)94,105,111,128
Automatic / manual
Output characteristicUm40Vrms sine
Im250mA
Um-dc20Vdc
Im-dc250mA
Re(Rg)Range0.02Ω~199.9kΩ
Basic accuracy2%+5
A single clampRange0.02Ω~19.99kΩ
Basic accuracy5%+5
Double clampRange0.02Ω~100Ω
Basic accuracy10%+2
RdcRange0.02Ω~1999Ω
Basic accuracy2%+2
ρ0~3768kΩ·m
Measurement of grounding
resistance (Rs) testing
Auxiliary grounding
resistance (Rh) testing
Remove the test function of Rk
LIMITalarm
beep
Power Supply8×1.5V AA Alkaline battery
Battery detection
Auto Power-off
Display type240 * 128 dot matrix
Backlight
RTC
Storage
CommunicationIsolation of USB communication
SafetyCAT Ⅲ 600V,Pollution degree 2
Overload protectionAC250V
High voltageAC3250V(50Hz/60Hz) / 5 seconds
Insulation resistance>50MΩ / DC 1KV
EMCClass B
AccessoriesThe 4 test line, 4 piles, 2 forceps
Size210×155×95
WeightAbout900g
Standard Quantity Per Carton1pcs
Standard Carton Measurement395mm*385mm*260mm
Standard Carton Cross Weight7.9Kg

 

Hot Products

VICTOR 85D True RMS 600V/10A/60mF Multimeter Intelligent Multi-Purpose Meters Automatically Identify ...
VICTOR 6012A Pen-Type Multimeter With 3 5/6 Digit Display True RMS Multimeter Non-Contact 600V AC/DC ...
ecer({videoId:"d9ex-DOwn_Y",videoId_local:"20210903_6131e156e835d.mp4",idContainer:"#qtGYCmr"}) ...
VICTOR VC9205 1999 3 1/2 Large LCD Display Manual Range Digital Multimeter With Frequency And ...
VICTOR 88C Manual Range Digital Multimeter 1999 Counts large LCD Display With True RMS 1000V/20A AC ...
VICTOR 79 Digital Multimeter 2 In 1 4-20mA Signal Output Multimeter Process Signal Source 40MΩ RTD ...