Home Companies Shenzhen Veikong Electric Co., Ltd.

Single Phase Solar Water Pump Inverter 2.2kw 4kw 5.5kw 7.5kw For Submersible Pump

Shenzhen Veikong Electric Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China

Contact name:Terry

Inquir Now

Shenzhen Veikong Electric Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Single Phase Solar Water Pump Inverter 2.2kw 4kw 5.5kw 7.5kw For Submersible Pump

Country/Region china
City & Province shenzhen
Categories Professional Audio, Video & Lighting
InquireNow

Product Details

Solar water pump inverter single phase three phase 2.2kw 4kw 5.5kw 7.5kw

 

VEIKONG is professional manufacturer of solar pump inverter, variable frequency dirve, soft starter.

 

 

Electrical Specifications and Power degree

 

 220V380V
Max input DC voltage450V810V
DC voltage range150~450VDC300~810VDC
Normal working DC voltage260V-400V400V-650V
Recommended input mppt voltage330V550V
MPPT efficiency>99%
Rated output voltage1/3-phase 220VAC3-phase 380-480VAC
Output frequency range50/60Hz
Max efficiency of the machine99%
Power range220v 0.75kw to 75kw, 380v 1.5kw-160kw
Cooling methodAir cooling
Protection degreeIP20/IP65
AltitudeBelow 1000m; above 1% for every additional 100m.
StandardCE/ROHS

 

Noted: We suggest solar panel power should be 1.3-1.4 times higher than solar pump power ,

And solar pump inverter power should be higher level than solar pump.

When solar pump distance to inverter higher than 100m,

It should be equipped with Output reactor or higher level power inverter.

For Solar panel,total VOC less than Maximum DC voltage of inverter and Solar panel vmp is recommend

530V for 380V pump and 305V for 220V pump.

 

 

VEIKONG VFD500-PV solar pump inverter Features:

 

●  Worldwide applicable voltage levels and power ranges

Supports 220V single/three-phase, 380V three-phase water pumps, power ranges from 0.75kW to 200kW.

 

●  Fully intelligent

  • Simply connect the photovoltaic panels to the inverter, no need to set any parameters and the water pump will start automatically when powered on.

  • Automatic adjustment of the water output in response to changes in sunlight.

  • Automatic dormancy in weak light (e.g. after sunset), withdrawal from dormancy in strong light (e.g. at sunrise).

  • Automatic dormancy when the water level is high and automatic restart when the water level is low, enabling automatic water level control.

  • Specially designed for water pump users, easy to operate and adaptable to various applications.

 

●  Multiple protection

Protection features such as PV over-voltage protection, PV reverse polarity alarm, automatic over-temperature derating, etc. can effectively extend the product life

 

●  Advanced MPPT technology

Ensures solar tracking efficiency up to 99%

 

●  AC/DC switching solution

The whole series of products can automatically switch between PV DC input and grid AC input, which can meet 24-hour water consumption and no manual operation is required.

 

 

Product Application

 
 
 

 

FAQ
1. How to achieve Automatic start after stop?
If it is controlled by keyboard no need to set any parameter. If you want to control by external switch
As the default control mode is keypad control, First set P00.06=1 and use a wire or switch to connect com
and DI1,When the switch is closed, the drive run, when the switch is open, the drive stop
 
2. How to design solar PV water pump system?
Key point: the rated VOC and VMP and power of the PV Array need to match the input range of
the inverter. If needed, we will provide technical support online.
 
3. How to use a float in the water tank to stop the pump if the tank is full?
If your float signal is digital signal Use float switch to short DI 3 and com ,see diagram 1.3
 
4. How to set minimum frequency ( for example) 30hz and maximum 50HZ
Set P47.05=30HZ and 47.06 to some time and 47.07 to some time. Please refer to details of P47.05-47.07
 
5. If pump is 60HZ frequency, how to set max frequency?
Notice: If your motor rated frequency is 60HZ First solution for you, P01.06=P01.08=P11.05=60HZ.
Quick setting and easier way: you should set P00.11=02 If your motor is three phase; if your motor is single
phase with capacitor ,set P00.11=22;If your motor is single phase without capacitor ,set P00.11=32
 

 

 

Hot Products

Mini IP20 380V 0.75KW 1.5KW 2.2KW 4KW VFD Frequency Inverter For AC Motor VFD500M Series Features ...
Mini IP20 380V 2.2KW 4KW 5.5KW 7.5KW VFD Frequency Inverter For AC Motor VFD500M Series Features and ...
Mini IP20 220V 380V 0.4KW To 7.5KW VFD Frequency Inverter For AC Motor VFD500M Series Features and ...
1.5KW 2.2KW 4KW 5.5KW VFD Variable Frequency Drive 3phase With LCD Keyboard Product Features VFD500 ...
7.5KW 11KW 15KW 18.5KW VFD Variable Frequency Drive 3phase With LCD Keyboard Product Features The ...
7.5KW 11KW 15KW 18.5KW VFD Frequency Inverter 3 Phase With LCD Keyboard Product Features of Three ...