GPRS MPPT 5.5kw 7.5kw 11kw Single Phase three phase solar pump inverter

 

Product Details and Features:

 

VFD500-PV Seires High Performance Solar Pump Inverter

Power range: 0.75~75kw 220V

0.75~160kw 380V

 

1. MPPT with 99% high efficiency

2. Driving for AC induction motor or PMSM

3. GPRS remote monitoring and control

4. Long service life working and long warranty

5. Maximum DC power input: 450VDC for 220AC output /810VDC for 380V AC output

6. Easy install and operation, no need set parameters

7. Optional LCD keypad, no need use manual

8. A variety of protection, drying runing protection, water fulling protection, overvoltage protection, overcurrent protection

9. Built in PID function, when MPPT control, PID is also enable.

10. Connect DC and AC power, inverter can work 24 hours.

 

1. VEIKONG solar water pump system is essentially an electrical pump system in which the electricity is provided by one or several PhotoVoltaic (PV) panels. A typical solar powered pumping system consists of a solar panel array that powers an electric motor, which in turn powers a bore or surface pump.

 

 

2. What is solar pump inverter?

A solar inverter or PV inverter,solar pump inverter,solar pump controller,solar water pump inverter,solar pump drive,solar water pump controller,solar mppt vfd,solar mppt frequency inverter,solar frequency inverter,solar pump vsd,solar frequency inverter,solar vfd are all key words

IT is a type of electrical converter which converts the variable direct current (DC) output of a photovoltaic (PV) solar panel into a utility frequency alternating current (AC) that can be fed into a commercial electrical grid or used by a local, off-grid electrical network.

 

It is able to convert DC voltage coming from solar panels into AC voltage for powering any pump driven by a three-phase motor.

Pump speed is constantly adapted to available solar irradiation thus maximising the amount of pumped water and making possible operation even in conditions of low sunlight.

It also offers complete pump protection against surges, overloads and dry running.

 

Electrical Specifications and Power degree

 

 220V380V
Max input DC voltage450V810V
DC voltage range150~450VDC300~810VDC
Normal working DC voltage260V-400V400V-650V
Recommended input mppt voltage330V550V
MPPT efficiency>99%
Rated output voltage1/3-phase 220VAC3-phase 380-480VAC
Output frequency range50/60Hz
Max efficiency of the machine99%
Power range220v 0.75kw to 75kw, 380v 1.5kw-160kw
Cooling methodAir cooling
Protection degreeIP20/IP65
AltitudeBelow 1000m; above 1% for every additional 100m.
StandardCE/ROHS

 

 

Product Application

 
 

For 220V single phase motor connection

1: Single phase asynchronous motor wiring method (without starting capacitor):

Notice: U is connected to the common end of the starting winding and the working winding, V is connected to the starting winding, and W is connected to the working winding;

 

Single-phase asynchronous motor if the rotary steering is not correct, you can change the V and W wiring or set P22.13=1.

 

First solution: Set parameter P11.01=1 (Single phase motor type without capacitor) or second solution: set P00.11=31 if your motor frequency is 50 hz or set P00.11=32 if your motor frequency is 60HZ

 

 

For 220V single phase motor connection

2: Single-phase asynchronous motor wiring method (with capacitor)

 

Notice1: First solution: Connect motor cable to power terminal U and V and enter BSC mode to Set parameter P23.15=0(output phase loss shielding protection) or second solution: set macro P00.11=21 if your motor frequency is 50HZ or set P00.11=22 if your motor frequency is 60HZ

 
 

 

 

Hot Products

11KW 15KW 18.5KW VFD Frequency Drive Vector Control With LCD Keyboard Product Features High...
11KW 15KW 18.5KW VFD Frequency Drive Inverter With V/F Control Technical Specifications Item ...
380V Three Phase In And 220V Single Phase Out VFD Variable Frequency Drive 1. Veikong VFD200A series ...
Mini VFD Variable Frequency Drive Low Voltage Economic Style AC Motor Drive 1. Veikong VFD500M ...
Mini IP20 220V 0.4KW 0.75KW 1.5KW 2.2KW VFD Frequency Inverter For AC Motor VFD500M Series Features ...
Mini IP20 380V 0.75KW 1.5KW 2.2KW 4KW VFD Frequency Inverter For AC Motor VFD500M Series Features ...