220v 2.2kw 4kw 50hz 60hz Off Grid Solar Pump Inverter IP20 IP65 Protection

Country/Region china
City & Province shenzhen
Categories Batteries
InquireNow

Product Details

Single phase pump solar pump inverter 220v 2.2kw 4kw 50hz 60hz

 

Model Range

 

Drive ModelRelated VoltageMax DC input voltage (V)Rated output current (A)Applicable water pump (KW)SIZE
VFD500M-20T00150-PV220V80071.5SIZE A
VFD500M-20T00220-PV220V80010.62.2SIZE A
VFD500M-40T00150-PV380V8004.21.5SIZE A
VFD500M-40T00220-PV380V80062.2SIZE A
VFD500-20T00150-PV220V80071.5SIZE A
VFD500-20T00220-PV220V80010.62.2SIZE A
VFD500-20T00400-PV220V800174SIZE A
VFD500-40T00150-PV380V8004.21.5SIZE A
VFD500-40T00220-PV380V80062.2SIZE A
VFD500-40T00400-PV380V8009.44SIZE A
VFD500-40T00550-PV380V800135.5SIZE B
VFD500-40T00750-PV380V800177.5SIZE B
VFD500-40T01100-PV380V8002511SIZE C
VFD500-40T01500-PV380V8003215SIZE C
VFD500-40T01850-PV380V8003818.5SIZE D
VFD500-40T02200-PV380V8004622SIZE D
VFD500-40T03000-PV380V8006030SIZE E
VFD500-40T03700-PV380V8007537SIZE E
VFD500-40T04500-PV380V8009645SIZE F
VFD500-40T05500-PV380V80011255SIZE F
VFD500-40T07500-PV380V80015075SIZE G
VFD500-40T09000-PV380V80017690SIZE G
VFD500-40T11000-PV380V800210110SIZE H
VFD500-40T13200-PV380V800253132SIZE I
VFD500-40T16000-PV380V800304160SIZE I
VFD500-40T18500-PV380V800340185SIZE J
VFD500-40T20000-PV380V800377200SIZE J

 

 

Key Advantages:

 

1, Maximizing power generation efficiency of solar modules with the use of advanced MPPT control technology. 

 

2,, Adjust water outflow of pumps quickly on basis of sunlight intensity change.

 

3, Built-in C3 EMC filter and DSP technology and Infineon PIM design,with functions of light weak protection,

dry run and low voltage,full water warning, overvoltage and overtemperature protection.

 

4, Advanced calculation for Pump flow and LCD monitoring display.

 

5, Automatic running without any commisioning in keypad control and GPRS monitoring option(as option).

 

6, Dual supply capability with change over switch - solar and grid compatible.

 

 

Techincal Parameters:

 

1. Wake up and sleep function parameters:

 

P47.05Light detection thresholdIf the output frequency is lower than this value and exceeds P47.06, it will be reported to Sleep and stop0Hz
P47.06Light detection timeSee P47.05 for explanation.60s
P47.07Light weak wake up timeAfter the sleep fault is reported, if the time when Vdc is higher than the undervoltage point is greater than the set value, the fault state is exited and the operation continues.600s

 

2. Dry runing protection function parameters:

 

P24.12Dry run/Unload protection option

0: No offload detection is performed;

1: Enable dry run detection

1
P24.13Dry run/Unload detection level

0.0 to 200.0%

The percentage of motor rated current.

0.0%
P24.14Dry run Unload detection time0.000s~60.000s30.000s
P24.15Unload detection offset frequency

0.00Hz~Fmax

Detection frequency=Fmax-P24.15

 

5.00Hz
P24.16Reset time of dry run protection0.0~6000.0240.0s
P23.21Dry run detection mode

0000:Coast stop

1000:Fast stop

3000:Continue to run

0000

 

3. Water full protection function parameters:

 

P47.18Full water level detection channel

0:ineffective

1:AI1

2:AI2

3:AI3

4:AI4

Note: DI terminal function code 60-full water level detection is same with Analogue detection, and the detection time and recovery time are the same.

0
P47.19Full water level detection value

0.0~100.0%

 

 

0.0%
P47.20Full water level detection time

0.0~3000.0s

When DI-60 is valid or meets the analog detection channel greater than P47.19 and maintains P47.20 time, the system reports A.Full and stops.

 

10.0s
P47.21Full water recovery time

0.0~3000.0s

When the condition described in P47.20 does not meet full water level detection requirement ,it will be returned to normal state after delay

10.0s

 

 

Conditions for full water detection to take effect:

 

1. Any DI terminal set to No. 60 function receives the input switch closing signal.

For example, after P06.03 is set to 60, DI3 closes.

 

2. The analog input is greater than the detection value,

for example: set P47.18 = 1, P47.19 = 50%, then the AI1 input is greater than 5V or 10mA

 

3. After the condition 1 or 2 is met, continue to set the time at P47.20

And the system will report A.FULL Full water recovery conditions

 

4. The system enters the full water detection stage and displays A.FULL

 

5. When both conditions 1 and 2 are not met and the maintenance time is greater than the time set in P47.21, the system resumes.

 
 
 
Product application pictures
 

 

Hot Products

5.5KW 7.5KW 11KW 15KW 18.5KW VFD AC Drive Manufacturer Vector Control 5.5KW 7.5KW 11KW 15KW 18.5KW ...
AC 380v 220v IP20 OVP VFD Variable Frequency Drive Manufacturers 30kw 40hp variable frequency drive ...
VFD Variable Frequency Inverter For Heavy Load 30kw 37kw 45kw 55kw VFD ac drive frequency inverter ...
380V Input VFD Variable Frequency Drive 0.75kw To 710kw Three Phase AC drive vfd variable speed ...
7HP 10HP 15HP 25HP 30HP Frequency Inverter AC Drive With Vector Control Product Advantages 1, With ...
560KW 630KW 710KW Frequency Drive For AC Motor Crusher Machine High performance 1. More Accurate ...