Home Companies Shenzhen Veikong Electric Co., Ltd.

Overload Protection 15 Hp Soft Starter Three Phase Soft Starter 11kw

Shenzhen Veikong Electric Co., Ltd.

Contact Us

[China] country

Trade Verify

Address: 4F, Building 5, Dongluyang Industrial ,Park, No. 4, Tengfeng 4th Road, Fuyong Phoenix Third, Industrial Zone, Baoan District, Shenzhen China

Contact name:Terry

Inquir Now

Shenzhen Veikong Electric Co., Ltd.

Verified Suppliers
  • Trust
    Seal
  • Verified
    Supplier
  • Credit
    Check
  • Capability
    Assessment

Overload Protection 15 Hp Soft Starter Three Phase Soft Starter 11kw

Country/Region china
City & Province shenzhen
Categories Power Supplies
InquireNow

Product Details

11kw 15hp 3 phase 220v 380v 11kw soft starter ac frequency inverter

 

 

Key Feature

 

1, Six group parameters convenient in one soft starter to different power motors load.

 

2, Dynamic fault recording function and Inspecting motor feedback to realize closed loop control to give best motor start up in different conditions and different loads.

 

3, A variety of ways starting:voltage RAMP starting way can get the maximum output torque;Current limiting can realize biggest Limitations of the Start soft starting current.

 

4, Reliable quality Assurance:using computer simulation design;SMT Production process;Electromagnetic Compatibility Excellent.

Performance;High temperature aging,Vibration Test before delivery of the machine.

 

 

Product technical characteristics

 

Main circuit working voltage: AC380V (+ 10% ~ - 25%); Main circuit working current: 22A ~ 560A;

Main circuit frequency: 50Hz / 60Hz (± 2%); Soft start rise time: 2 ~ 60s;

Soft parking time: 0 ~ 60s; Current limit multiples: 1.5 ~ 5.0Ie; Initial voltage: 30% ~ 70% Ue; Cooling method: fan cooling;

Communication method: RS485 serial communication;

 

Kick mode

Kickstart mode output change waveform. In some heavy occasions, due

to mechanical static friction can not start the motor, you can use this starting mode. At start-up, a high fixed voltage is applied to the motor for a limited period of time to overcome the static friction of the motor load, causing the motor to rotate and then starting in either current- limiting (Figure 1) or voltage ramp (Figure 2) .

 

Before using this mode, you should start the motor with non-sudden jump mode. If the motor can not rotate because the static friction force is too big, then select this mode or you should avoid using this mode to start, so as to reduce unnecessary high current impact.

 

Technical Specification

 

Item

Description

Input Power Supply

Input Voltage

Three-phase 380V/480V/660 AC

Frequency

50/60Hz

Adaptive Motor

Squirrel-cage three-phase asynchronous motor

Starting Times

It is recommended not to exceed 20 times per hour.

 

 

 

Control Mode

(1) Operation panel control.

(2) Operation panel + external control.

(3) External control.

(4) External control + COM control.

(5) Operation panel + external + COM control.

(6) Operation panel + COM control.

(7) COM control.

(8) No start or stop operation.

 

 

Start Mode

(1) Current-limiting to start.

(2) Voltage ramp to start.

(3) Torque control + current-limiting to start.

(4) Torque control + voltage ramp to start.

(5) Current ramp to start.

(6) Voltage current-limiting double closed-loop start.

Stop Mode

(1) Soft stop.

(2) Free stop.

 

 

 

 

 

 

Protective Function

(1) Open loop protection for external instantaneous stop terminals.

(2) Over-heat protection for soft starter.

(3) Protection for too long starting time.

(4) Input open phase protection.

(5) Output open phase protection.

(6) Unbalanced three-phase protection.

(7) starting over current protection.

(8) Running overload protection.

(9) Under voltage protection for power voltage.

(10) Overvoltage protection for power voltage.

(11) Protection for fault parameter setting.

(12) Load short circuit protection.

(13) Auto restart or incorrect wiring protection.

(14) Incorrect wiring protection of external control stop terminals.

 

 

Ambient

Place to be used

Indoor location with good ventilation free from corrosive gas and conductive dust.

Altitude

Below 1000M. It have to rise the rate power when the altitude is more than 1000M.

Temperature

-20 +45 C

Humidity

90%RH without dew condensation.

Vibration

<0.5G

Structure

Protection Class

IP20

Cooling Pattern

Fans cooling.

 

Product Application

 
 

 

Hot Products

5.5KW 7.5KW 11KW 15KW 18.5KW VFD AC Drive Manufacturer Vector Control 5.5KW 7.5KW 11KW 15KW 18.5KW ...
AC 380v 220v IP20 OVP VFD Variable Frequency Drive Manufacturers 30kw 40hp variable frequency drive ...
VFD Variable Frequency Inverter For Heavy Load 30kw 37kw 45kw 55kw VFD ac drive frequency inverter ...
380V Input VFD Variable Frequency Drive 0.75kw To 710kw Three Phase AC drive vfd variable speed ...
7HP 10HP 15HP 25HP 30HP Frequency Inverter AC Drive With Vector Control Product Advantages 1, With ...
560KW 630KW 710KW Frequency Drive For AC Motor Crusher Machine High performance 1. More Accurate ...