1. Use level probe in the well for protection against dry running
First solution: See self learning of dry run
Second solution: do it manually Set P24.13=30%-60%(as per real
empty load current percentage based on
rated current) and P24.14 P24.16 and P23.21
Third solution: If your sensor is digital switch ,just short D4 and
com
Fourth solution: If your float signal is Analog signal, Connect Ai2
and 10V and GND and set P41.00=23 and
P41.03-P41.06
2. How to set minimum frequency ( for example) 30hz and maximum
50HZ
Set P47.05=30HZ and 47.06 to some time and 47.07 to some time.
Please refer to details of P47.05-47.07